English
Related papers

Related papers: Zero field magnetic resonance spectroscopy based o…

200 papers

Nitrogen vacancy (NV) centers in diamond have been used as ultrasensitive magnetometers to perform nuclear magnetic resonance (NMR) spectroscopy of statistically polarized samples at 1 - 100 nm length scales. However, the spectral linewidth…

Quantum sensing based on nitrogen-vacancy (NV) centers in diamond has been developed as a powerful tool for microscopic magnetic resonance. However, the reported sensor-to-sample distance is limited within tens of nanometers because the…

We show how nitrogen vacancy (NV) centers can be used to determine the amplitude, phase and frequency of unknown weak monochromatic and multichromatic oscillating magnetic fields using only the periodic dynamical decoupling (PDD) and…

Quantum Physics · Physics 2014-04-14 Adam Zaman Chaudhry

Quantum sensing exploits the strong sensitivity of quantum systems to measure small external signals. The nitrogen-vacancy (NV) center in diamond is one of the most promising platforms for real-world quantum sensing applications,…

Quantum Physics · Physics 2022-05-12 Ziwei Qiu , Uri Vool , Assaf Hamo , Amir Yacoby

Nuclear magnetic resonance (NMR) schemes can be applied to micron-, and nanometer-sized samples by the aid of quantum sensors such as nitrogen-vacancy (NV) color centers in diamond. These minute devices allow for magnetometry of nuclear…

Quantum Physics · Physics 2021-07-19 C. Munuera-Javaloy , R. Puebla , J. Casanova

Magnetometry using Nitrogen-Vacancy (NV) color centers in diamond predominantly relies on microwave spectroscopy. However, microwaves may hinder certain studies involving biological systems or thin conductive samples. This work demonstrates…

Magnetic resonance spectroscopy of single biomolecules under near-physiological conditions may substantially advance understanding of biological function, yet remains very challenging. Here we use nitrogen-vacancy centers in diamonds to…

The isolated electronic spin system of the Nitrogen-Vacancy (NV) centre in diamond offers unique possibilities to be employed as a nanoscale sensor for detection and imaging of weak magnetic fields. Magnetic imaging with nanometric…

Mesoscale and Nanoscale Physics · Physics 2014-08-19 L. Rondin , J. -P. Tetienne , T. Hingant , J. -F. Roch , P. Maletinsky , V. Jacques

Nano-NMR spectroscopy with nitrogen-vacancy centers holds the potential to provide high resolution spectra of minute samples. This is likely to have important implications for chemistry, medicine and pharmaceutical engineering. One of the…

Quantum Physics · Physics 2020-06-23 Daniel Cohen , Ramil Nigmatullin , Matan Eldar , Alex Retzker

A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or…

Magnetic Resonance Imaging (MRI) can characterize and discriminate among tissues using their diverse physical and biochemical properties. Unfortunately, submicrometer screening of biological specimens is presently not possible, mainly due…

Mesoscale and Nanoscale Physics · Physics 2010-11-03 C. A. Meriles , L. Jiang , G. Goldstein , J. S. Hodges , J. R. Maze , M. D. Lukin , P. Cappellaro

We describe a scanning device where a single spin is used as an ultrasensitive, nanoscale magnetic field sensor. As this "probe spin" we consider a single nitrogen-vacancy defect center in a diamond nanocrystal, attached to the tip of the…

Mesoscale and Nanoscale Physics · Physics 2008-09-23 C. L. Degen

Nitrogen-vacancy (NV) centers in nanodiamonds have emerged as a promising quantum sensing platform for biomedical imaging applications, yet random orientations of individual particles present significant challenges in large-scale sensor…

Quantum Physics · Physics 2025-07-09 Yizhou Wang , Haochen Shen , Zhongyuan Liu , Yue Yu , Shengwang Du , Chong Zu , Chuanwei Zhang

The application of magnetic resonance (MR) spectroscopy at progressively smaller length scales may eventually permit "chemical imaging" of spins at the surfaces of materials and biological complexes. In particular, the negatively charged…

Mesoscale and Nanoscale Physics · Physics 2015-06-18 Hai-Jing Wang , Chang S. Shin , Scott J. Seltzer , Claudia E. Avalos , Alexander Pines , Vikram S. Bajaj

We demonstrate vector magnetometry with an ensemble of nitrogen-vacancy (NV) centers in diamond without the need for an external bias field. The anisotropy of the electric dipole moments of the NV center reduces the ambiguity of the…

Mesoscale and Nanoscale Physics · Physics 2017-01-05 Franz Münzhuber , Johannes Kleinlein , Tobias Kiessling , Laurens W. Molenkamp

The localized spin triplet ground state of a nitrogen vacancy (NV) center in diamond can be used in atomic-scale detection of local magnetic fields. Here we present a technique using these defects in diamond to image fields around magnetic…

Mesoscale and Nanoscale Physics · Physics 2015-05-14 B. J. Maertz , A. P. Wijnheijmer , G. D. Fuchs , M. E. Nowakowski , D. D. Awschalom

Nitrogen-vacancy (NV) centers are defects in diamonds, which, due to their electronic structure, have been extensively studied as magnetic field sensors. Such field detection applications usually employ the NV centers to detect field…

Quantum Physics · Physics 2016-06-07 Shonali Dhingra , Brian D'Urso

We demonstrate a synchronized readout (SR) technique for spectrally selective detection of oscillating magnetic fields with sub-millihertz resolution, using coherent manipulation of solid state spins. The SR technique is implemented in a…

An unusual regime for liquid-state nuclear magnetic resonance (NMR) where the magnetic field strength is so low that the $J$-coupling (intramolecular spin-spin) interactions dominate the spin Hamiltonian opens a new paradigm with…

Atomic Physics · Physics 2019-10-02 Dmitry Budker

Ensembles of nitrogen-vacancy (NV) centers in diamonds are widely utilized for magnetometry, magnetic-field imaging and magnetic-resonance detection. They have not been used for magnetometry at zero ambient field because Zeeman sublevels…