English
Related papers

Related papers: Noise Optimization for MKIDs with Different Design…

200 papers

The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank…

Instrumentation and Methods for Astrophysics · Physics 2016-09-02 L. Bisigello , S. J. C. Yates , L. Ferrari , J. J. A. Baselmans , A. M. Baryshev

The Lumped Element Kinetic Inductance Detectors (LEKID)demonstrated full maturity in the NIKA (New IRAM KID Arrays)instrument. These results allow directly comparing LEKID performance with other competing technologies (TES, doped silicon)…

Instrumentation and Methods for Astrophysics · Physics 2016-03-23 J. Goupy , A. Adane , A. Benoit , O. Bourrion , M. Calvo , A. Catalano , G. Coiffard , C. Hoarau , S. Leclercq , H. Le Sueur , J. Macias-Perez , A. Monfardini , I. Peck , K. Schuster

Kinetic Inductance Detectors (KIDs) have emerged as a leading technology for millimeter- and submillimeter-wave astronomy due to their high sensitivity, natural multiplexing capabilities and scalable fabrication. In polarization-sensitive…

In this paper, we investigate the single photon response from the reflection of the Microwave Kinetic Inductance Detector (MKID) array. Reflection measurements are carried out using two configurations: one is measured simultaneously with…

Instrumentation and Methods for Astrophysics · Physics 2024-06-17 Jie Hu , Faouzi Boussaha , Paul Nicaise , Christine Chaumont , Maria Appavou , Viet Dung Pham , Michel Piat

We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single…

Instrumentation and Detectors · Physics 2016-10-14 P. Szypryt , B. A. Mazin , G. Ulbricht , B. Bumble , S. R. Meeker , C. Bockstiegel , A. B. Walter

Data are presented on inductance of various features used in superconductor digital integrated circuits such as microstrip and stripline inductors with linewidths down to 120 nm and different combinations of ground plane layers, effect of…

Superconductivity · Physics 2021-08-11 Sergey. K. Tolpygo , Evan B. Golden , Terence J. Weir , Vladimir Bolkhovsky

One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and…

Instrumentation and Methods for Astrophysics · Physics 2021-08-31 S. Shu , M. Calvo , J. Goupy , S. Leclercq , A. Catalano , A. Bideaud , A. Monfardini , E. F. C. Driessen

We are developing superconducting Microwave Kinetic Inductance Detectors to operate at near infrared and optical wavelengths for astronomy. In order to efficiently meet with the requirements of astronomical applications, we propose to…

Instrumentation and Methods for Astrophysics · Physics 2019-01-30 S. Beldi , F. Boussaha , C. Chaumont , S. Mignot , F. Reix , A. Tartari , T. Vacelet , A. Traini , M. Piat , P. Bonifacio

The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and…

Instrumentation and Detectors · Physics 2015-09-15 L. Cardani , I. Colantoni , A. Cruciani , S. Di Domizio , M. Vignati , F. Bellini , N. Casali , M. G. Castellano , A. Coppolecchia , C. Cosmelli , C. Tomei

We demonstrate photon counting at 1550 nm wavelength using microwave kinetic inductance detectors (MKIDs) made from TiN/Ti/TiN trilayer films with superconducting transition temperature Tc ~ 1.4 K. The detectors have a lumped-element design…

Instrumentation and Detectors · Physics 2017-06-07 W. Guo , X. Liu , Y. Wang , Q. Wei , L. F. Wei , J. Hubmayr , J. Fowler , J. Ullom , L. Vale , M. R. Vissers , J. Gao

We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on…

Instrumentation and Detectors · Physics 2014-11-18 R. M. J. Janssen , A. Endo , P. J. de Visser , T. M. Klapwijk , J. J. A. Baselmans

We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting…

The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called…

Achieving the quantum noise targets of third-generation detectors will require 10 dB of squeezed-light enhancement as well as megawatt laser power in the interferometer arms - both of which require unprecedented control of the internal…

Instrumentation and Methods for Astrophysics · Physics 2022-05-31 Jonathan W. Richardson , Swadha Pandey , Edita Bytyqi , Tega Edo , Rana X. Adhikari

Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance…

Instrumentation and Detectors · Physics 2020-01-29 S. Ruffieux , A. Kalaboukhov , M. Xie , M. Chukharkin , C. Pfeiffer , S. Sepehri , J. F. Schneiderman , D. Winkler

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good…

Instrumentation and Methods for Astrophysics · Physics 2016-02-15 L. Bisigello , S. J. C. Yates , V. Murugesan , J. J. A. Baselmans , A. M. Baryshev

Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors…

In the next decades millimeter and sub-mm astronomy requires large format imaging arrays and broad-band spectrometers to complement the high spatial and spectral resolution of the Atacama Large Millimeter/sub-millimeter Array. The desired…

Instrumentation and Methods for Astrophysics · Physics 2014-08-15 R. M. J. Janssen , J. J. A. Baselmans , A. Endo , L. Ferrari , S. J. C. Yates , A. M. Baryshev , T. M. Klapwijk

We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists…

We report on the noise of a lumped element Direct Current Superconducting Quantum Interference Device amplifier. We show that the noise temperature in the 4 GHz-8 GHz range over ranges of 10's of MHz is below 1 kelvin (three photons of…

Superconductivity · Physics 2015-05-20 Lafe Spietz , Kent Irwin , Minhyea Lee , Jose Aumentado