Related papers: X-ray imaging with Micromegas detectors with optic…
In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of…
We present a comprehensive analysis of the X-ray observations obtained from \xmm\, and \chandra\, for a sample of bona-fide Compact Symmetric Objects (CSOs) to investigate their X-ray emission properties. Ultimately, we obtain 32 effective…
Modern microscopy techniques are developing towards high-resolution imaging, and tremendous progress has been made in past decades; however, the imaging of individual biological macromolecules at atomic resolution using short-wavelength…
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas…
We have developed MICROMEGAS (MICRO MEsh GASeous) detectors for detecting {\alpha} particles emitted from an 241-Am standard source. The voltage applied to the ionization region of the detector is optimized for stable operation at room…
This work presents a high-resolution X-ray microtomography system that uses commercial off-the-shelf (COTS) CMOS image sensors as direct detectors, relying on the sensor s intrinsic resolution to achieve tomographic reconstructions without…
In recent years, scientific Complementary Metal Oxide Semiconductor (sCMOS) devices have been increasingly applied in X-ray detection, thanks to their attributes such as high frame rate, low dark current, high radiation tolerance and low…
The detection of gamma-ray emission from accreting pulsars in X-ray binaries (XRBs) has long been sought after. For some high-mass X-ray binaries (HMXBs), marginal detections have recently been reported. Regardless of whether these will be…
A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different…
Arrays of low-temperature microcalorimeters provide a promising technology for X-ray astrophysics: the imaging spectrometer. A camera with at least several thousand pixels, each of which has an energy-resolving power ($E/\Delta…
In spite of their ubiquitous applications, the characterization of glass fibers by means of all-optical techniques is still facing some limitations. Recently, X-ray absorption has been proposed as a method for visualizing the inner…
The T-REX project aims at developing novel readout techniques for Time Projection Chambers in experiments searching for rare events. The enhanced performance of the latest Micromegas readouts in issues like energy resolution, gain…
We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…
As part of an experiment to measure the spectrum of photons emitted in beta-decay of the free neutron, we developed and operated a detector consisting of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs). The…
When an X-ray is incident onto the silicon absorber array of a detector, it liberates a large number of electrons, which tend to diffuse outward into what is referred to as the charge cloud. This number can vary from tens to thousands…
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point…
Beam monitoring and evaluation are very important to boron neutron capture therapy (BNCT), and a variety of detectors have been developed for these applications. However, most of the detectors used in BNCT only have a small detection area,…
The progress of miniaturisation in integrated electronics has led to atomic and nanometre-sized dopant devices in silicon. Such structures can be fabricated routinely by hydrogen resist lithography, using various dopants such as phosphorous…
A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated…
A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI…