Related papers: Extended Depth-of-Field Lensless Imaging using an …
Mask-based lensless cameras offer a novel design for imaging systems by replacing the lens in a conventional camera with a layer of coded mask. Each pixel of the lensless camera encodes the information of the entire 3D scene. Existing…
Mask-based lensless cameras can be flat, thin, and light-weight, which makes them suitable for novel designs of computational imaging systems with large surface areas and arbitrary shapes. Despite recent progress in lensless cameras, the…
Conventional stereo suffers from a fundamental trade-off between imaging volume and signal-to-noise ratio (SNR) -- due to the conflicting impact of aperture size on both these variables. Inspired by the extended depth of field cameras, we…
Lensless cameras provide a framework to build thin imaging systems by replacing the lens in a conventional camera with an amplitude or phase mask near the sensor. Existing methods for lensless imaging can recover the depth and intensity of…
There is growing interest in the use of coded aperture imaging systems for a variety of applications. Using an analysis framework based on mutual information, we examine the fundamental limits of such systems---and the associated optimum…
Mask-based lensless imaging uses an optical encoder (e.g. a phase or amplitude mask) to capture measurements, then a computational decoding algorithm to reconstruct images. In this work, we evaluate and design lensless encoders based on the…
Depth of field is an important factor of imaging systems that highly affects the quality of the acquired spatial information. Extended depth of field (EDoF) imaging is a challenging ill-posed problem and has been extensively addressed in…
We present a proof-of-concept end-to-end system for computational extended depth of field (EDOF) imaging. The acquisition is performed through a phase-coded aperture implemented by placing a thin wavelength-dependent optical mask inside the…
Photoacoustic microscopy with large depth of focus is significant to the biomedical research. The conventional optical-resolution photoacoustic microscope (OR-PAM) suffers from limited depth of field (DoF) since the employed focused…
Reducing the aperture size is a conventional technique to obtain enhanced image resolution in optics but it is obscured by depleting illumination. Polarization coded apertures (PCAs) can be employed to circumvent this critical artifact. We…
In optical imaging, achieving high resolution often comes at the expense of a shallow depth of field. This means that when using a standard microscope, any minor movement of the object along the optical axis can cause the image to become…
Coherent diffractive imaging (CDI) provides new opportunities for high resolution X-ray imaging with simultaneous amplitude and phase contrast. Extensions to CDI broaden the scope of the technique for use in a wide variety of experimental…
Lensless imaging can provide visual privacy due to the highly multiplexed characteristic of its measurements. However, this alone is a weak form of security, as various adversarial attacks can be designed to invert the one-to-many scene…
Imaging at hard X-ray energies (~10-600 keV) over very large fields of view (~60 deg per telescope) is required to conduct a high sensitivity all-sky and all-time survey for black holes. The proposed Energetic X-ray Imaging Survey Telescope…
Mask-based lensless imagers use simple optics and computational reconstruction to design compact form factor cameras with compressive imaging ability. However, these imagers generally suffer from poor reconstruction quality. Here, we…
Mask-based lensless cameras replace the lens of a conventional camera with a custom mask. These cameras can potentially be very thin and even flexible. Recently, it has been demonstrated that such mask-based cameras can recover light…
Recently, a method of recording holograms of coherently illuminated three-dimensional scene without two-wave interference was demonstrated. The method is an extension of the coded aperture correlation holography from incoherent to coherent…
Optical imaging systems are generally limited by the depth of field because of the nature of the optics. Therefore, extending depth of field (EDoF) is a fundamental task for meeting the requirements of emerging visual applications. To solve…
The Lunar Electromagnetic Monitor in X-rays (LEM-X) is a proposed wide-field X-ray observatory designed for deployment on the Moon's surface. Its primary scientific goal is to enhance multi-messenger astrophysics by detecting, localizing,…
Recently, coded masks have been used to demonstrate a thin form-factor lensless camera, FlatCam, in which a mask is placed immediately on top of a bare image sensor. In this paper, we present an imaging model and algorithm to jointly…