English
Related papers

Related papers: Muon radiography experiments on the subway overbur…

200 papers

Solar, terrestrial, and supernova neutrino experiments are subject to muon-induced radioactive backgrounds. The China Jinping Underground Laboratory (CJPL), with its unique advantage of a 2400 m rock coverage and long distance from nuclear…

The installation of the muon telescope detector opened new possibilities for studying dimuon production at STAR. However, backgrounds from hadron punch-through and weak decays of pions and kaons make the identification of primary muons…

Instrumentation and Detectors · Physics 2019-08-21 J. D. Brandenburg , Frank Geurts

Purpose: A geometric simulation of a possible two-plane detector was developed to test the abilities of the detector to generate high-resolution images of the Great Pyramid using muon tomography. Methods and Materials: Trajectory range,…

Image and Video Processing · Electrical Eng. & Systems 2024-02-29 Mira Liu

The upcoming MUonE experiment aims to precisely measure the running of the fine structure constant via elastic muon-electron scattering, to shed light on the current tension in the muon's anomalous magnetic moment. In addition to its…

High Energy Physics - Phenomenology · Physics 2025-11-06 Duncan Rocha , Isaac R. Wang

Next-generation microreactors enable remote deployment and semi-autonomous operation, but compact, sealed, heterogeneous cores limit conventional safeguard approaches that rely on access and bulk accountancy. Limited inspection access and…

Applied Physics · Physics 2026-03-09 Reshma Ughade , Stylianos Chatzidakis

Muon Induced X-ray Emission (MIXE) was discovered by Chinese physicist Zhang Wenyu as early as 1947, and it can conduct non-destructive elemental analysis inside samples. Research has shown that MIXE can retain the high efficiency of direct…

Instrumentation and Detectors · Physics 2024-11-06 Dikai Li , Jian Yu , Qian Chen , Ziming Li , Chunhui Zhang , Xiangyu Wan , Zhibing He , Leifeng Cao

The Underground Muon Detector of the Pierre Auger Observatory features a calorimetric detection mode that estimates the number of muons based on signal charge measurements. This contribution provides an overview of the calibration…

Instrumentation and Detectors · Physics 2025-07-25 Marina Scornavacche

The muon intensity and angular distribution in the shallow-underground laboratory Felsenkeller in Dresden, Germany have been studied using a portable muon detector based on the close cathode chamber design. Data has been taken at four…

Instrumentation and Detectors · Physics 2019-05-10 F. Ludwig , L. Wagner , T. Al-Abdullah , G. G. Barnaföldi , D. Bemmerer , D. Degering , K. Schmidt , G. Surányi , T. Szücs , K. Zuber

Cosmic-ray muons can be used for the non-destructive imaging of spent nuclear fuel in sealed dry storage casks. The scattering data of the muons after traversing provides information on the thereby penetrated materials. Based on these…

Instrumentation and Detectors · Physics 2021-02-17 T. Braunroth , N. Berner , F. Rowold , M. Péridis , M. Stuke

The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in…

Instrumentation and Detectors · Physics 2015-09-29 T. Adam , F. An , G. An , Q. An , N. Anfimov , V. Antonelli , G. Baccolo , M. Baldoncini , E. Baussan , M. Bellato , L. Bezrukov , D. Bick , S. Blyth , S. Boarin , A. Brigatti , T. Brugière , R. Brugnera , M. Buizza Avanzini , J. Busto , A. Cabrera , H. Cai , X. Cai , A. Cammi , D. Cao , G. Cao , J. Cao , J. Chang , Y. Chang , M. Chen , P. Chen , Q. Chen , S. Chen , S. Chen , S. Chen , X. Chen , Y. Chen , Y. Cheng , D. Chiesa , A. Chukanov , M. Clemenza , B. Clerbaux , D. D'Angelo , H. de Kerret , Z. Deng , Z. Deng , X. Ding , Y. Ding , Z. Djurcic , S. Dmitrievsky , M. Dolgareva , D. Dornic , E. Doroshkevich , M. Dracos , O. Drapier , S. Dusini , M. A. Díaz , T. Enqvist , D. Fan , C. Fang , J. Fang , X. Fang , L. Favart , D. Fedoseev , G. Fiorentini , R. Ford , A. Formozov , R. Gaigher , H. Gan , A. Garfagnini , G. Gaudiot , C. Genster , M. Giammarchi , F. Giuliani , M. Gonchar , G. Gong , H. Gong , M. Gonin , Y. Gornushkin , M. Grassi , C. Grewing , V. Gromov , M. Gu , M. Guan , V. Guarino , W. Guo , X. Guo , Y. Guo , M. Göger-Neff , P. Hackspacher , C. Hagner , R. Han , Z. Han , J. Hao , M. He , D. Hellgartner , Y. Heng , D. Hong , S. Hou , Y. Hsiung , B. Hu , J. Hu , S. Hu , T. Hu , W. Hu , H. Huang , X. Huang , X. Huang , L. Huo , W. Huo , A. Ioannisian , D. Ioannisyan , M. Jeitler , K. Jen , S. Jetter , X. Ji , X. Ji , S. Jian , D. Jiang , X. Jiang , C. Jollet , M. Kaiser , B. Kan , L. Kang , M. Karagounis , N. Kazarian , S. Kettell , D. Korablev , A. Krasnoperov , S. Krokhaleva , Z. Krumshteyn , A. Kruth , P. Kuusiniemi , T. Lachenmaier , L. Lei , R. Lei , X. Lei , R. Leitner , F. Lenz , C. Li , F. Li , F. Li , J. Li , N. Li , S. Li , T. Li , W. Li , W. Li , X. Li , X. Li , X. Li , X. Li , Y. Li , Y. Li , Z. Li , H. Liang , H. Liang , J. Liang , M. Licciardi , G. Lin , S. Lin , T. Lin , Y. Lin , I. Lippi , G. Liu , H. Liu , H. Liu , J. Liu , J. Liu , J. Liu , J. Liu , Q. Liu , Q. Liu , S. Liu , S. Liu , Y. Liu , P. Lombardi , Y. Long , S. Lorenz , C. Lu , F. Lu , H. Lu , J. Lu , J. Lu , J. Lu , B. Lubsandorzhiev , S. Lubsandorzhiev , L. Ludhova , F. Luo , S. Luo , Z. Lv , V. Lyashuk , Q. Ma , S. Ma , X. Ma , X. Ma , Y. Malyshkin , F. Mantovani , Y. Mao , S. Mari , D. Mayilyan , W. McDonough , G. Meng , A. Meregaglia , E. Meroni , M. Mezzetto , J. Min , L. Miramonti , M. Montuschi , N. Morozov , T. Mueller , P. Muralidharan , M. Nastasi , D. Naumov , E. Naumova , I. Nemchenok , Z. Ning , H. Nunokawa , L. Oberauer , J. P. Ochoa-Ricoux , A. Olshevskiy , F. Ortica , H. Pan , A. Paoloni , N. Parkalian , S. Parmeggiano , V. Pec , N. Pelliccia , H. Peng , P. Poussot , S. Pozzi , E. Previtali , S. Prummer , F. Qi , M. Qi , S. Qian , X. Qian , H. Qiao , Z. Qin , G. Ranucci , A. Re , B. Ren , J. Ren , T. Rezinko , B. Ricci , M. Robens , A. Romani , B. Roskovec , X. Ruan , X. Ruan , A. Rybnikov , A. Sadovsky , P. Saggese , G. Salamanna , J. Sawatzki , J. Schuler , A. Selyunin , G. Shi , J. Shi , Y. Shi , V. Sinev , C. Sirignano , M. Sisti , O. Smirnov , M. Soiron , A. Stahl , L. Stanco , J. Steinmann , V. Strati , G. Sun , X. Sun , Y. Sun , Y. Sun , D. Taichenachev , J. Tang , A. Tietzsch , I. Tkachev , W. H. Trzaska , Y. Tung , S. van Waasen , C. Volpe , V. Vorobel , L. Votano , C. Wang , C. Wang , C. Wang , G. Wang , H. Wang , M. Wang , R. Wang , S. Wang , W. Wang , W. Wang , Y. Wang , Y. Wang , Y. Wang , Y. Wang , Z. Wang , Z. Wang , Z. Wang , Z. Wang , Z. Wang , W. Wei , Y. Wei , M. Weifels , L. Wen , Y. Wen , C. Wiebusch , S. Wipperfurth , S. C. Wong , B. Wonsak , C. Wu , Q. Wu , Z. Wu , M. Wurm , J. Wurtz , Y. Xi , D. Xia , J. Xia , M. Xiao , Y. Xie , J. Xu , J. Xu , L. Xu , Y. Xu , B. Yan , X. Yan , C. Yang , C. Yang , H. Yang , L. Yang , M. Yang , Y. Yang , Y. Yang , Y. Yang , E. Yanovich , Y. Yao , M. Ye , X. Ye , U. Yegin , F. Yermia , Z. You , B. Yu , C. Yu , C. Yu , G. Yu , Z. Yu , Y. Yuan , Z. Yuan , M. Zanetti , P. Zeng , S. Zeng , T. Zeng , L. Zhan , C. Zhang , F. Zhang , G. Zhang , H. Zhang , J. Zhang , J. Zhang , J. Zhang , K. Zhang , P. Zhang , Q. Zhang , T. Zhang , X. Zhang , X. Zhang , Y. Zhang , Y. Zhang , Y. Zhang , Y. Zhang , Y. Zhang , Y. Zhang , Z. Zhang , Z. Zhang , J. Zhao , M. Zhao , T. Zhao , Y. Zhao , H. Zheng , M. Zheng , X. Zheng , Y. Zheng , W. Zhong , G. Zhou , J. Zhou , L. Zhou , N. Zhou , R. Zhou , S. Zhou , W. Zhou , X. Zhou , Y. Zhou , H. Zhu , K. Zhu , H. Zhuang , L. Zong , J. Zou

In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector…

Instrumentation and Detectors · Physics 2017-04-05 Y. P. Zhang , J. L. Xu , H. Q. Lu , P. Zhang , C. C. Zhang , C. G. Yang

Measuring the muon flux is important to the Sanford Underground Laboratory at Homestake, for which several low background experiments are being planned. The nearly-vertical cosmic ray muon flux was measured in three locations at this…

Nuclear Experiment · Physics 2011-04-05 F. E. Gray , C. Ruybal , J. Totushek , D. -M. Mei , K. Thomas , C. Zhang

Muon Spin Rotation/Relaxation/Resonance ($\mu$SR) is a versatile and powerful non-destructive technology for investigating the magnetic properties of materials at the microscopic level. The $\mu$SR technique typically utilizes fully spin…

Muon colliders offer special opportunities to discover and study new physics. With the high intensity source of muons at the front end, orders of magnitude improvements would be realized in searches for rare muon processes, in deep…

High Energy Physics - Phenomenology · Physics 2009-10-31 V. Barger

We have measured the muon flux and production rate of muon-induced neutrons at a depth of 611 m water equivalent. Our apparatus comprises three layers of crossed plastic scintillator hodoscopes for tracking the incident cosmic-ray muons and…

The Large Volume Detector (LVD), hosted in the INFN Laboratori Nazionali del Gran Sasso, is triggered by atmospheric muons at a rate of $\sim 0.1$~Hz. The data collected over almost a quarter of century are used to study the muon intensity…

The MACRO detector was located in the Hall B of the Gran Sasso underground Laboratories under an average rock overburden of 3700 hg/cm^2. A transition radiation detector composed of three identical modules, covering a total horizontal area…

High Energy Physics - Experiment · Physics 2009-11-07 The MACRO Collaboration , M. Ambrosio

Project GRAND has the capability of measuring the angle and identity of single tracks of secondary muons at ground level. The array is comprised of 64 stations each containing eight proportional wire planes with a 50 mm steel absorber plate…

Astrophysics · Physics 2007-05-23 J. Poirier , C. D'Andrea , M. Dunford

We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very…