English
Related papers

Related papers: Josephson parametric circulator with same-frequenc…

200 papers

We demonstrate a Josephson parametric amplifier design with a band-pass impedance matching network based on a third-order Chebyshev prototype. We measured eight amplifiers operating at 4.6 GHz that exhibit gains of 20 dB with less than 1 dB…

We develop a concept of the traveling-wave Josephson parametric amplifier exploiting quadratic nonlinearity of a serial array of one-junction SQUIDs embedded in a superconducting transmission line. The external magnetic flux applied to the…

Superconductivity · Physics 2016-09-20 A. B. Zorin

A directional superconducting parametric amplifier in the GHz frequency range is designed and analyzed, suitable for low-power read-out of microwave kinetic inductance detectors employed in astrophysics and when combined with a…

Superconductivity · Physics 2018-06-20 M. P. Westig , T. M. Klapwijk

Linear parametric amplification is a key operation in information processing. Our interest here is quantum-limited parametric amplification, $i.e.$, amplification of quantum signals while adding the minimum amount of noise allowed by…

Quantum Physics · Physics 2018-07-10 Ananda Roy , Michel Devoret

Circulators and directional amplifiers are crucial non-reciprocal signal routing and processing components involved in microwave readout chains for a variety of applications. They are particularly important in the field of superconducting…

Quantum Physics · Physics 2015-11-11 K. M. Sliwa , M. Hatridge , A. Narla , S. Shankar , L. Frunzio , R. J. Schoelkopf , M. H. Devoret

We propose and demonstrate a new read-out technique for a superconducting qubit by dispersively coupling it to a Josephson parametric oscillator. We employ a tunable quarter-wavelength superconducting resonator and modulate its resonant…

High-fidelity quantum non-demolition qubit measurement is critical to error correction and rapid qubit feedback in large-scale quantum computing. High-fidelity readout requires passing a short and strong pulse through the qubit's readout…

We study the dynamics of a driven atomic Josephson junction that we propose as a parametric amplifier. By periodically modulating the position of the barrier, we induce a small current across the junction, serving as our input signal. The…

Quantum Gases · Physics 2026-05-29 Vijay Pal Singh , Luigi Amico , Ludwig Mathey

We develop a technique to overcome phase-mismatch in Josephson-junction traveling wave parametric amplifiers in order to achieve high gain over a broad bandwidth. Using "resonant phase matching," we design a compact superconducting device…

Superconductivity · Physics 2014-10-15 Kevin O'Brien , Chris Macklin , Irfan Siddiqi , Xiang Zhang

Nonreciprocal microwave devices play several critical roles in high-fidelity, quantum-nondemolition (QND) measurement schemes. They separate input from output, impose unidirectional routing of readout signals, and protect the quantum…

We present experimental results on a Josephson parametric amplifier tailored for readout of ultra-sensitive thermal microwave detectors. In particular, we discuss the impact of fabrication details on the performance. We show that the small…

The cryogenic hardware required to build a superconducting qubit based quantum computer demands a variety of microwave components. These elements include microwave couplers, filters, amplifiers, and circulators/isolators. Traditionally…

Quantum Physics · Physics 2024-06-05 M. A. Beck , M. Selvanayagam , A. Carniol , S. Cairns , C. P. Mancini

We have developed a concept for a traveling-wave parametric amplifier driven by a magnetic flux wave. The circuit consists of a serial array of symmetric dc SQUIDs coupled inductively to a separate superconducting LC transmission line…

Superconductivity · Physics 2019-11-01 A. B. Zorin

Determining the state of a qubit on a timescale much shorter than its relaxation time is an essential requirement for quantum information processing. With the aid of a new type of non-degenerate parametric amplifier, we demonstrate the…

We demonstrate Josephson junction based double-balanced mixer and phase shifter circuits operating at 6-10 GHz, and integrate these components to implement both a monolithic amplitude/phase vector modulator and a quadrature mixer. The…

Superconductivity · Physics 2017-02-24 O. Naaman , J. A. Strong , D. G. Ferguson , J. Egan , N. Bailey , R. T. Hinkey

We present design and simulation of a Josephson parametric amplifier with bandwidth exceeding 1.6 GHz, and with high saturation power approaching -90 dBm at a gain of 22.8 dB. An improvement by a factor of roughly 50 in bandwidth over the…

Instrumentation and Detectors · Physics 2017-11-22 O. Naaman , D. G. Ferguson , R. J. Epstein

High gain and large bandwidth of traveling-wave parametric amplifier exploiting the nonlinearity of Josephson Junctions can be achieved by fulfilling the so-called phase-matching condition. This condition is usually addressed by placing…

Superconductivity · Physics 2025-08-12 Emil Rizvanov , Samuel Kern , Pavol Neilinger , Miroslav Grajcar

Josephson-junction based parametric amplifiers have become a ubiquitous component in superconducting quantum machines. Although parametric amplifiers regularly achieve near-quantum limited performance, they have many limitations, including…

Quantum Physics · Physics 2020-05-06 T. -C. Chien , O. Lanes , C. Liu , X. Cao , P. Lu , S. Motz , G. Liu , D. Pekker , M. Hatridge

Nonreciprocal microwave devices, such as circulators, are useful in routing quantum signals in quantum networks and protecting quantum systems against noise coming from the detection chain. However, commercial, cryogenic circulators, now in…

Superconductivity · Physics 2017-09-22 Baleegh Abdo , Markus Brink , Jerry M. Chow

We demonstrate full frequency conversion in the microwave domain using a Josephson three-wave mixing device pumped at the difference between the frequencies of its fundamental eigenmodes. By measuring the signal output as a function of the…

‹ Prev 1 2 3 10 Next ›