Related papers: Timing resistive plate chambers for thermal neutro…
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…
Recently we have proposed a new concept of a thermal neutron detector based on resistive plate chambers and 10B4C solid neutron converters, enabling to readout with high resolution in both the 3D position of neutron capture and the neutron…
We propose an alternative approach for the detection of fast neutrons in the energy range from 10-4 to 5 MeV based on 10B-RPCs (hybrid double-gap Resistive Plate Chambers with 10B4C neutron converters) surrounded by a polyethylene…
A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures…
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…
Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…
Composite detectors made of stainless steel converters and multigap resistive plate chambers have been irradiated with quasi-monoenergetic neutrons with a peak energy of 175MeV. The neutron detection efficiency has been determined using two…
A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…
This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient…
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…
Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a…
A Monte Carlo simulation-based optimization of a multilayer 10B-RPC thermal neutron detector is performed targeting an increase in the counting rate capability while maintaining high (>50%) detection efficiency for thermal neutrons. The…
We report on the design, production, and performance of compact 40-cm$^3$ Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in $^4$He:CO$_2$ gas at…
We present the results of the measurements of the detection efficiency for a 4.7 \r{A} neutron beam incident upon a detector incorporating a stack of up to five MultiWire Proportional Counters (MWPC) with Boron-coated cathodes. The cathodes…
A large area Resistive Plate Chamber (RPC) with a total active surface of 160x10 cm2 was built and tested. The surface was segmented in two 5 cm wide strips readout on both ends with custom, very high frequency, front end electronics. A…
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…
Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…
A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…