Related papers: Absolute frequency measurements with a robust, tra…
Optical frequency comparison of the 40Ca+ clock transition \nu_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition \nu_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio \nu_{Ca} / \nu_{Sr} = 0.957 631 202 358…
The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We…
We report a frequency measurement of the clock transition of a single ^40Ca^+ ion trapped and laser cooled in a miniature ring Paul trap with 10^-15 level uncertainty. In the measurement, we used an optical frequency comb referenced to a…
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain…
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…
A transportable optical clock refer to the $4s^2S_{1/2}-3d^2D_{5/2}$ electric quadrupole transition at 729 nm of single $^{40}Ca^+$ trapped in mini Paul trap has been developed. The physical system of $^{40}Ca^+$ optical clock is…
We present a compact, long-term nearly continuous operation of a room-temperature Ca$^+$ optical clock setup towards a transportable clock, achieving an overall systematic uncertainty of $4.8\times 10^{-18}$ and an uptime rate of 97.8% over…
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical…
We report on an absolute frequency measurement of the ${\rm Lu}^{+}\,(^{3}\rm D_1)$ standard frequency which is defined as the hyperfine-average of $^{1}\rm S_0$ to $^{3}\rm D_1$ optical clock transitions in $^{176}{\rm Lu}^{+}$. The…
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the…
We report the absolute frequency measurement of the 5s2 1S0-5s5p 3P0 transition in 87Sr optical lattice clock (Sr1) at National Time Service Center (NTSC). Its systematic frequency shifts are evaluated carefully with a total relative…
We report on a $^{88}$Sr$^{+}$ single-ion optical clock with an estimated fractional systematic uncertainty of $7.9\times 10^{-19}$. The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation…
The absolute frequency of the $^{87}{\rm Sr}$ lattice clock transition was evaluated with an uncertainty of $1.1\times 10^{-15}$ using a frequency link to the international atomic time (TAI). The frequency uncertainty of a hydrogen maser…
Quantum-logic-based ${}^{27}\textrm{Al}^+$ optical clock has been demonstrated in several schemes as there are different choices of the auxiliary ion species. In this paper, we present the first detailed evaluation of the systematic shift…
The absolute frequency of the $^{87}{\rm Sr}$ clock transition measured in 2015 was reevaluated using an improved frequency link to the SI second. The scale interval of International Atomic Time (TAI) that we used as the reference was…
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave…
The absolute frequency of the In$^{+}$ $5s^{2 1}S_{0}$ - $5s5p^{3}P_{0}$ clock transition at 237 nm was measured with an accuracy of 1.8 parts in $10^{13}$. Using a phase-coherent frequency chain, we compared the $^{1}S_{0}$ - $^{3}P_{0}$…
We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…
The optical lattice clock NICT-Sr1 regularly reports calibration measurements of the international timescale TAI. By comparing measurement results to the reports of eight Primary Frequency Standards, we find the absolute frequency of the…
We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved…