Related papers: The CCD Controller and Detector
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The CYGNO project has the goal to use a gaseous TPC with optical readout to detect dark matter and solar neutrinos with low energy threshold and directionality. The CYGNO demonstrator will consist of 1 m 3 volume filled with He:CF 4 gas…
The Cassegrain-Teleskop-Kamera (CTK) is a new CCD imager which is operated at the University Observatory Jena since begin of 2006. This article describes the main characteristics of the new camera. The properties of the CCD detector, the…
A full simulation of a transition radiation detector (TRD) based on the GEANT, GARFIELD, MAGBOLTZ and HEED codes has been developed. This simulation can be used to study and develop TRD for high energy particle identification using either…
The innermost part of the ATLAS experiment will be a pixel detector containing around 1750 individual detector modules. A detector control system (DCS) is required to handle thousands of I/O channels with varying characteristics. The main…
The goal of the TANGERINE project is to develop the next generation of monolithic silicon pixel detectors using a 65 nm CMOS imaging process, which offers a higher logic density and overall lower power consumption compared to previously…
The CYGNO project aims at the development of a high precision optical readout gaseous Tima Projection Chamber (TPC) for directional dark matter (DM) searches, to be hosted at Laboratori Nazionali del Gran Sasso (LNGS). CYGNO employs a…
We review advances in low temperature detector (LTD) arrays for Cosmic Microwave Background (CMB) polarization experiments, with a particular emphasis on imaging arrays. We briefly motivate the science case, which has spurred a large number…
The CALDER project aims at developing cryogenic light detectors with high sensitivity to UV and visible light, to be used for particle tagging in massive bolometers. Indeed the sensitivity of CUORE can be increased by a factor of 3, thanks…
We review the basic features of transition radiation and how they are used for the design of modern Transition Radiation Detectors (TRD). The discussion will include the various realizations of radiators as well as a discussion of the…
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high…
Abstract: Solid state sensors having timing capabilities are becoming an absolute need in particle tracking techniques of future experiments at colliders. In this sense, silicon sensors having 3D structure are becoming an interesting…
The Cherenkov Telescope Array Observatory (CTAO) will be the largest and most advanced ground-based facility for gamma-ray astronomy. Several dozens of telescopes will be operated at both the Northern and Southern Hemisphere. With the…
The Detector Control System (DCS) of the COMPASS experiment at CERN is presented. The experiment has a high level of complexity and flexibility and a long time of operation, that constitute a challenge for its full monitorisation and…
The wavefront sensor (WFS), equipped with an electron-multiplying charge-coupled device (EMCCD) detector, is a critical component of the Cool Planets Imaging Coronagraph (CPI-C) on the Chinese Space Station Telescope (CSST). Precise…
The prevalent use of large volume liquid argon detectors strongly motivates the development of novel readout and monitoring technology which functions at cryogenic temperatures. This paper presents the development of a cryogenic CMOS camera…
This work verifies the instrumental characteristics of the CCD detector which is part of the UNI astronomical observatory. We measured the linearity of the CCD detector of the SBIG STXL6303E camera, along with the associated gain and…
Astronomical CCD systems based on second-generation DINACON controllers were developed at the SAO RAS Advanced Design Laboratory more than seven years ago and since then have been in constant operation at the 6-meter and Zeiss-1000…
We present a conceptual design of a high-performance camera system with applications to neutrino detectors, deep sea exploration, and glaciology. The design combines ultra-sensitive cameras with a number of well-calibrated light sources…
Capacitive devices are customarily used as probes to measure the level of noble liquids in detectors operated for neutrino studies and dark matter searches. In this work we describe the use of a high-temperature superconducting material as…