English
Related papers

Related papers: Calculation of true coincidence summing correction…

200 papers

The true coincidence summing effect on the full-energy peak efficiency calibration of an unsuppressed clover HPGe detector has been studied. Standard multi-energetic and mono-energetic gamma-ray sources were used to determine the…

Instrumentation and Detectors · Physics 2023-09-06 Ashish Gupta , M. Shareef , Munmun Twisha , Saikat Bhattacharjee , A. Mukherjee

A Monte Carlo method based on the GEANT4 toolkit has been developed to correct the full-energy peak (FEP) efficiencies of a high purity germanium (HPGe) detector equipped with a low background shielding system, and moreover evaluated using…

Instrumentation and Detectors · Physics 2018-01-01 Liu-Chun He , Li-Jun Diao , Bao-Hua Sun , Li-Hua Zhu , Jian-Wei Zhao , Meng Wang , Kang Wang

Uncertainty propagation to the $\gamma$-$\gamma$ coincidence-summing correction factor from the covariances of the nuclear data and detection efficiencies have been formulated. The method was applied in the uncertainty analysis of the…

Instrumentation and Detectors · Physics 2023-08-09 V. Semkova , N. Otuka , A. J. M. Plompen

A high-purity co-axial germanium detector has been calibrated in efficiency to a precision of about 0.15% over a wide energy range. High-precision scans of the detector crystal and gamma-ray source measurements have been compared to…

``Oversimplified'' and ``simplified'' methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and…

Instrumentation and Detectors · Physics 2022-06-22 Victor V. Golovko

In this paper we model by using the Monte Carlo simulation code PENELOPE [1, 2] a Broad Energy Germanium (BEGe) detector and determine its efficiency. The simulated geometry consists of a point source located close to the detector as well…

Instrumentation and Detectors · Physics 2014-11-18 N. Stefanakis

An electrically cooled Broad Energy Germanium (BEGe) detector has been characterized in the energy range E$_{\gamma}$ $\sim$ 0.122 - 7 MeV by utilizing the $\gamma$- rays emitted by a short-lived resonance state in $^{15}$O populated…

Instrumentation and Detectors · Physics 2020-04-22 Sathi Sharma , Arkabrata Gupta , Balaram Dey , M. Roy Chowdhury , A. Mandal , A. Bisoi , V. Nanal , L. C. Tribedi , M. Saha Sarkar

The measurement of gamma-rays from decaying nuclei allow for the investigation into nuclear structure. True coincidence summing occurs when two gamma-rays from a single decay get detected in a single detector and their energies sum together…

Instrumentation and Detectors · Physics 2026-02-16 Liam Schmidt

Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…

Instrumentation and Detectors · Physics 2020-04-08 B. Blank , P. Ascher , M. Gerbaux , J. Giovinazzo , S. Grevy , T. Kurtukian Nieto , M. Versteegen , J. C. Thomas

The reliable detection of the global 21-cm signal, a key tracer of Cosmic Dawn and the Epoch of Reionization, requires meticulous data modelling and robust statistical frameworks for model validation and comparison. In Paper I of this…

High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays…

This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic…

Instrumentation and Detectors · Physics 2016-03-03 M. Salathe , T. Kihm

Procedures for correcting the beam-beam effects in luminosity measurements at CLIC at 3 TeV center-of-mass energy are described and tested using Monte Carlo simulations. The angular counting loss due to the combined Beamstrahlung and…

Accelerator Physics · Physics 2015-06-12 Strahinja Lukic

In an ideal germanium detector, fully-absorbed monoenergetic gamma-rays will appear in the measured spectrum as a narrow peak, broadened into a Gaussian of width determined only by the statistical properties of charge cloud generation and…

Instrumentation and Methods for Astrophysics · Physics 2023-08-03 Steven E. Boggs , Sean N. Pike

We present measurements of electron and hole trapping in three COSI germanium cross-strip detectors. By characterizing the relative charge collection efficiency (CCE) as a function of interaction depth, we show that intrinsic trapping of…

Instrumentation and Detectors · Physics 2023-10-26 Sean N. Pike , Steven E. Boggs , Jacqueline Beechert , Jarred Roberts , Albert Y. Shih , John A. Tomsick , Andreas Zoglauer

Tomographic Gamma Scanning (TGS) is a technique used to assay the nuclide distribution and radioactivity in nuclear waste drums. Both transmission and emission scans are performed in TGS and the transmission image is used for the…

Nuclear Experiment · Physics 2014-04-18 Ke Wang , Zheng Li , Wei Feng , Dong Han

Doing quantitative computed tomography (CT) using Bremsstrahlung sources requires an estimate of the spectrum emitted by the X-ray source. One method of beam hardening correction (BHC), as described by Lifton[1], first uses transmission…

Medical Physics · Physics 2025-08-13 Nikhil Deshmukh

The second generation of gravitational-wave detectors is scheduled to start operations in 2015. Gravitational-wave signatures of compact binary coalescences could be used to accurately test the strong-field dynamical predictions of general…

General Relativity and Quantum Cosmology · Physics 2015-06-22 Walter Del Pozzo , Katherine Grover , Ilya Mandel , Alberto Vecchio

A model-independent method is proposed to characterize and correct charge sharing spectral distortions in energy-resolved X-ray acquisitions with pixellated photon-counting detectors. The technique is based on the determination of a…

We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60…

Instrumentation and Detectors · Physics 2020-04-02 R. W. Gladen , V. A. Chirayath , A. J. Fairchild , M. T. Manry , A. R. Koymen , A. H. Weiss
‹ Prev 1 2 3 10 Next ›