English
Related papers

Related papers: Machine Learning based tool for CMS RPC currents q…

200 papers

The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at…

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High-Luminosity LHC (HL-LHC). A new timing layer is…

Instrumentation and Detectors · Physics 2018-10-02 Irene Dutta

The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying…

Instrumentation and Detectors · Physics 2022-01-04 Mitali Mondal , Tanay Dey , Subhasis Chattopadhyay , Jogender Saini , Zubayer Ahammed

The ALICE muon trigger (MTR) system consists of 72 Resistive Plate Chamber (RPC) detectors arranged in two stations, each composed of two planes with 18 RPCs per plane. The detectors are operated in maxi-avalanche mode using a mixture of…

This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed…

Instrumentation and Detectors · Physics 2024-02-26 V. Kumar , S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat , A. Youssef

This work reports a cost-effective, multi-parameter readout and data-acquisition system for a muon scattering tomography system based on Resistive Plate Chambers (RPCs). Initial test measurements with a prototype Resistive Plate Chamber…

Instrumentation and Detectors · Physics 2022-06-01 Subhendu Das , Sridhar Tripathy , Sandip Sarkar , Nayana Majumdar , Supratik Mukhopadhyay

The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks,…

The CMS muon system operates gas-based detectors. Upgrades of the detectors and trigger components are needed to cope with increasingly challenging conditions of the HL-LHC. New irradiation tests are performed to ensure that the muon…

Instrumentation and Detectors · Physics 2018-09-07 Jian Wang

The high pseudorapidity ($\eta$) region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds…

Instrumentation and Detectors · Physics 2020-01-29 E. Voevodina , I. Crotty

The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the…

Instrumentation and Detectors · Physics 2022-08-31 R. Aly

The CMS muon system at the LHC is built of different detector technologies. The measurement of the background hit rates in the different muon detectors during the LHC Run-2 is of prime importance for an assessment of the longevity of the…

Instrumentation and Detectors · Physics 2020-04-22 Silvia Costantini

The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of…

Instrumentation and Detectors · Physics 2016-09-21 F. Lagarde , M. Gouzevitch , I. Laktineh , V. Buridon , X. Chen , C. Combaret , A. Eynard , L. Germani , G. Grenier , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeuraa , Y. Wang , A. Gongab , N. Moreau , C. de la Taille , F. Dulucqac , A. Cimmino , S. Crucy , A. Fagot , M. Gul , A. A. O. Rios , M. Tytgat , N. Zaganidisb , S. Aly , Y. Assran , A. Radi , A. Sayedc , G. Singhd , M. Abbrescia , G. Iaselli , M. Maggi , G. Pugliese , P. Verwilligene , W. Van Doninck , S. Colafranceschi , A. Sharmag , L. Benussi , S. Bianco , D. Piccolo , F. Primaverah , V. Bhatnagar , R. Kumari , A. Mehta , J. Singhi , A. Ahmad , W. Ahmed , H. M. I. Asghar , I. M. Awan , R. Hoorani , S. Muhammad , H. Shahzad , M. A. Shah , S. W. Cho , S. Y. Choi , B. Hong , M. H. Kang , K. S. Lee , J. H. Lim , S. K. Parkk , M. S. Kiml , S. Carpinteyro Bernardino , I. Pedraza , C. Uribe Estradam , S. Carrillo Moreno , F. Vazquez Valencian , L. M. Panto , S. Buontempo , N. Cavallo , M. Esposito , F. Fabozzi , G. Lanza , I. Orso , L. Lista , S. Meola , M. Merola , P. Paolucci , F. Thyssen , A. Braghieri , A. Magnani , P. Montagna , C. Riccardi , P. Salvini , I. Vai , P. Vituloq , Y. Ban , S. J. Qianr , M. Choi , Y. Choi , J. Goh , D. Kimt , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , S. Stoykova , G. Sultanov , M. Vutovau , A. Dimitrov , L. Litov , B. Pavlov , P. Petkovv , I. Bagaturia , D. Lomidzew , C. Avila , A. Cabrera , J. C. Sanabria , I. Crottyy , J. Vaitkusz

Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In order to optimize their performance, it is of primary…

Instrumentation and Detectors · Physics 2020-06-03 W. Elmetenawee

A real-time autoencoder-based anomaly detection system using semi-supervised machine learning has been developed for the online Data Quality Monitoring system of the electromagnetic calorimeter of the CMS detector at the CERN LHC. A novel…

Instrumentation and Detectors · Physics 2024-07-31 Abhirami Harilal , Kyungmin Park , Manfred Paulini

This paper presents a streamlined framework for real-time processing and analysis of condition data from the CMS experiment Resistive Plate Chambers (RPC). Leveraging data streaming, it uncovers correlations between RPC performance metrics,…

High Energy Physics - Experiment · Physics 2025-04-15 A. Dimitrov , M. Tytgat , K. Mota Amarilo , A. Samalan , K. Skovpen , G. A. Alves , E. Alves Coelho , F. Marujo da Silva , M. Barroso Ferreira Filho , E. M. Da Costa , D. De Jesus Damiao , S. Fonseca De Souza , R. Gomes De Souza , L. Mundim , H. Nogima , J. P. Pinheiro , A. Santoro , M. Thiel , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Shopova , G. Sultanov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , E. Shumka , P. Cao , W. Diao , Q. Hou , H. Kou , Z. -A. Liu , J. Song , J. Zhao , S. J. Qian , C. Avila , D. A. Barbosa Trujillo , A. Cabrera , C. A. Florez , J. A. Reyes Vega , R. Aly , A. Radi , Y. Assran , I. Crotty , M. A. Mahmoud , M. Gouzevitch , G. Grenier , I. B. Laktineh , L. Mirabito , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegarp , B. Boghrati , M. Ebrahimi , F. Esfandi , Y. Hosseini , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , N. De Filippis , G. Iaselli , F. Loddo , G. Pugliese , D. Ramos , L. Benussi , S. Bianco , S. Meola , D. Piccolo , S. Buontempo , F. Carnevali , F. Fienga , L. Lista , P. Paolucci , A. Braghieri , P. Montagna , C. Riccardi , P. Salvini , P. Vitulo , E. Asilar , T. J. Kim , Y. Ryou , S. Choi , B. Hong , K. S. Lee , J. Goh , J. Shin , Y. Lee , I. Pedraza , C. Uribe Estrada , H. Castilla-Valdez , R. Lopez-Fernandez , A. Sanchez Hernandez , M. Ramirez Garcia , D. L. Ramirez Guadarrama , M. A. Shah , E. Vazquez , N. Zaganidis , A. Ahmad , M. I. Asghar , H. R. Hoorani , S. Muhammad , J. Eysermans

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

After a brief overview of the Compact Muon Solenoid (CMS) experiment, the status of construction, installation and commissioning is described. Very good progress has been achieved in the past year. Though many significant challenges still…

Instrumentation and Detectors · Physics 2007-07-09 Joseph R. Incandela

We present recent results of an extensive aging test, performed at the CERN Gamma Irradiation Facility on two single--gap RPC prototypes, developed for the LHCb Muon System. With a method based on a model describing the behaviour of an RPC…

The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector…

The ALICE Muon IDentifier is composed of 72 single-gap bakelite Resistive Plate Chambers, which have been operational since 2009 in maxi-avalanche mode (discrimination threshold:7 mV without amplification) with a…

Instrumentation and Detectors · Physics 2024-03-21 Alessandro Ferretti