Related papers: Ring Artifact Correction in Photon-Counting Spectr…

200 papers

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

Image and Video Processing · Electrical Eng. & Systems 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

Computer Vision and Pattern Recognition · Computer Science 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning.…

Image and Video Processing · Electrical Eng. & Systems 2022-02-02 Tao Ge , Maria Medrano , Rui Liao , Jeffrey F. Williamson , David G. Politte , Bruce R. Whiting , Joseph A. O'Sullivan

Sparse-view computed tomography (CT) has been adopted as an important technique for speeding up data acquisition and decreasing radiation dose. However, due to the lack of sufficient projection data, the reconstructed CT images often…

Image and Video Processing · Electrical Eng. & Systems 2023-06-27 Hong Wang , Minghao Zhou , Dong Wei , Yuexiang Li , Yefeng Zheng

Speed-of-sound is a biomechanical property for quantitative tissue differentiation, with great potential as a new ultrasound-based image modality. A conventional ultrasound array transducer can be used together with an acoustic mirror, or…

Computer Vision and Pattern Recognition · Computer Science 2018-07-20 Valery Vishnevskiy , Sergio J Sanabria , Orcun Goksel

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler

Spectral computed tomography (CT) is an emerging technology, that generates a multienergy attenuation map for the interior of an object and extends the traditional image volume into a 4D form. Compared with traditional CT based on…

Medical Physics · Physics 2022-07-27 Xiang Chen , Wenjun Xia , Ziyuan Yang , Hu Chen , Yan Liu , Jiliu Zhou , Yi Zhang

Sparse-view computed tomography (CT) is a promising solution for expediting the scanning process and mitigating radiation exposure to patients, the reconstructed images, however, contain severe streak artifacts, compromising subsequent…

Image and Video Processing · Electrical Eng. & Systems 2023-10-03 Chenglong Ma , Zilong Li , Junping Zhang , Yi Zhang , Hongming Shan

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

Image and Video Processing · Electrical Eng. & Systems 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng

During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…

Image and Video Processing · Electrical Eng. & Systems 2022-12-27 Hong Wang , Qi Xie , Yuexiang Li , Yawen Huang , Deyu Meng , Yefeng Zheng

X-ray photon-counting detector (PCD) offers low noise, high resolution, and spectral characterization, representing a next generation of CT and enabling new biomedical applications. It is well known that involuntary patient motion may…

Medical Physics · Physics 2022-10-20 Mengzhou Li , Chiara Lowe , Anthony Butler , Phil Butler , Ge Wang

Spectral computed tomography (CT) offers the possibility to reconstruct attenuation images at different energy levels, which can be then used for material decomposition. However, traditional methods reconstruct each energy bin individually…

Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…

Image and Video Processing · Electrical Eng. & Systems 2019-07-02 Wei-An Lin , Haofu Liao , Cheng Peng , Xiaohang Sun , Jingdan Zhang , Jiebo Luo , Rama Chellappa , Shaohua Kevin Zhou

Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…

Metal artifacts caused by the presence of metallic implants tremendously degrade the reconstructed computed tomography (CT) image quality, affecting clinical diagnosis or reducing the accuracy of organ delineation and dose calculation in…

In computer tomography, due to the presence of metal implants in the patient body, reconstructed images will suffer from metal artifacts. In order to reduce metal artifacts, metals are typically removed in projection images. Therefore, the…

Computer Vision and Pattern Recognition · Computer Science 2020-05-05 Lin Yuan , Yixing Huang , Andreas Maier

Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…

Medical Physics · Physics 2017-08-02 Hyung Suk Park , Sung Min Lee , Hwa Pyung Kim , Jin Keun Seo

The existence of metallic implants in projection images for cone-beam computed tomography (CBCT) introduces undesired artifacts which degrade the quality of reconstructed images. In order to reduce metal artifacts, projection inpainting is…

Computer Vision and Pattern Recognition · Computer Science 2022-11-30 Fuxin Fan , Yangkong Wang , Ludwig Ritschl , Ramyar Biniazan , Marcel Beister , Björn Kreher , Yixing Huang , Steffen Kappler , Andreas Maier

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

Computer Vision and Pattern Recognition · Computer Science 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao