The positron-electron pair annihilation in two photons is known for its numerous applications using PET scanners. The decay of Positronium (Ps) from a standard sealed source in more than two photons is less likely but can be observed with a…

Physics Education · Physics 2011-09-20 M. E. A. Elbasher , W. Erasmus , E. A. M. Khaleel , J. Ndayishimye , P. Papka

Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the…

This paper presents the model-based design and evaluation of an instrument that estimates incident neutron direction using the kinematics of neutron scattering by hydrogen-1 nuclei in an organic scintillator. The instrument design uses a…

Instrumentation and Detectors · Physics 2017-12-13 Kyle Weinfurther , John Mattingly , Erik Brubaker , John Steele

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

Discrimination of fast neutrons, thermal neutrons, and $\gamma$ rays in mixed radiation fields is important for radiation monitoring, reactor-related measurements, and background suppression in nuclear experiments. In this work, we…

Instrumentation and Detectors · Physics 2026-04-30 Yuhang Liu , Fengpeng An , Guang Luo , Wei Wang , Xuesong Zhang , Dixiao Lu , Xiaohao Yin

We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a…

Instrumentation and Detectors · Physics 2014-11-18 M. Cerv , P. Sarin , H. Pernegger , P. Vageesvaran , E. Griesmayer

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

We developed a 12-liter volume neutron detector filled with the liquid scintillator EJ301 that measures neutrons in an underground laboratory where dark matter and neutrino experiments are located. The detector target is a cylindrical…

Instrumentation and Detectors · Physics 2015-06-15 C. Zhang , D. -M. Mei , P. Davis , B. Woltman , F. Gray

In this paper, we introduce a laboratory prototype of a solar energetic particle (SEP) detector which will operate along with other space-based instruments to give us more insight into the SEP physics. The instrument is designed to detect…

Instrumentation and Detectors · Physics 2020-10-20 Egor Stadnichuk , Tatyana Abramova , Mikhail Zelenyi , Alexander Izvestnyy , Alexander Nozik , Vladimir Palmin , Ivan Zimovets

We propose a new scintillator-based tracker concept based on a monolithic plastic scintillator plate with embedded scatterers and wavelength-shifting fiber readout. The embedded scatterers localize scintillation light so that channels…

Instrumentation and Detectors · Physics 2026-04-06 Naoki Otani , Seungho Han , Shun Ito , Tatsuya Kikawa , Tsuyoshi Nakaya , Mihiro Suzuki , Atsushi Tokiyasu

The aim of this work was to test the impact of the lightguides insertion in the J-PET detection system and to choose the best of available solutions. At the two strip J-PET test system a series of measurements was performed with different…

Instrumentation and Detectors · Physics 2015-07-31 Dominika Alfs

Many scintillator based detectors employ a set of photomultiplier tubes (PMT) to observe the scintillation light from potential signal and background events. It is important to be able to count the number of photoelectrons (PE) in the…

Instrumentation and Detectors · Physics 2019-10-30 Kolahal Bhattacharya , Christopher Jackson

We present prototype modules for a tracking detector consisting of multiple layers of 0.25 mm diameter scintillating fibers that are read out by linear arrays of silicon photomultipliers. The module production process is described and…

Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since…

Instrumentation and Detectors · Physics 2020-02-26 Mihael Makek , Damir Bosnar , Luka Pavelić , Pavla Šenjug , Petar Žugec

A calorimetric polarimeter based on inorganic LYSO scintillators is described. It has been designed for use in a storage ring to search for electric dipole moments (EDM) of charged particles such as the proton and deuteron. Its development…

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks'…

We describe an apparatus used to measure the triple-correlation term (\D \hat{\sigma}_n\cdot p_e\times p_\nu) in the beta-decay of polarized neutrons. The \D-coefficient is sensitive to possible violations of time reversal invariance. The…

We develop a positronium imaging method for the Jagiellonian PET (J-PET) scanners based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM). The system matrix elements are calculated on-the-fly for the coincidences…

Instrumentation and Detectors · Physics 2023-10-19 Roman Y. Shopa , Kamil Dulski

The reliable detection of neutrons in a harsh gamma-ray environment is an important aspect of establishing non-destructive methods for the characterization of spent nuclear fuel. In this study, we present results from extended in-situ…

Instrumentation and Detectors · Physics 2021-10-22 Hanno Perrey , Linus Ros , Mikael Elfman , Ulrika Bäckström , Per Kristiansson , Anders Sjöland

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…