We review developments, issues and challenges in Electrical Impedance Tomography (EIT), for the 4th Workshop on Biomedical Applications of EIT, Manchester 2003. We focus on the necessity for three dimensional data collection and…

Medical Physics · Physics 2008-07-31 William R. B. Lionheart

In acousto-electric tomography the goal is to reconstruct the electric conductivity in a domain from electrostatic boundary measurements of corresponding currents and voltages, while the domain is penetrated by a time-dependent acoustic…

Medical Physics · Physics 2024-02-01 Bjørn Jensen , Adrian Kirkeby , Kim Knudsen

Electrical impedance tomography (EIT) is a non-invasive imaging technique, which has been widely used in the fields of industrial inspection, medical monitoring and tactile sensing. However, due to the inherent non-linearity and…

Computer Vision and Pattern Recognition · Computer Science 2025-01-13 Duanpeng Shi , Wendong Zheng , Di Guo , Huaping Liu

An efficient computational approach for optimal reconstruction of binary-type images suitable for models in various applications including biomedical imaging is developed and validated. The methodology includes derivative-free optimization…

Optimization and Control · Mathematics 2022-09-27 Paul R. Arbic , Vladislav Bukshtynov

This paper presents a multi-resolution reconstruction method for Electrical Impedance Tomography (EIT), referred to as MR-EIT, which is capable of operating in both supervised and unsupervised learning modes. MR-EIT integrates an ordered…

Computer Vision and Pattern Recognition · Computer Science 2025-03-04 Fangming Shi , Jinzhen Liu , Xiangqian Meng , Yapeng Zhou , Hui Xiong

In this work we develop and analyze an adaptive finite element method for efficiently solving electrical impedance tomography -- a severely ill-posed nonlinear inverse problem for recovering the conductivity from boundary voltage…

Numerical Analysis · Mathematics 2019-05-16 Bangti Jin , Yifeng Xu , Jun Zou

We propose and test stable algorithms for the reconstruction of the internal conductivity of a biological object using acousto-electric measurements. Namely, the conventional impedance tomography scheme is supplemented by scanning the…

Analysis of PDEs · Mathematics 2015-05-20 Peter Kuchment , Leonid Kunyansky

Parallel-beam X-ray computed tomography (CT) and electrical impedance tomography (EIT) are two imaging modalities which stem from completely different underlying physics, and for decades have been thought to have little in common either…

This paper discusses the reconstruction of partially sampled spectrum-images to accelerate the acquisition in scanning transmission electron microscopy (STEM). The problem of image reconstruction has been widely considered in the literature…

Image and Video Processing · Electrical Eng. & Systems 2020-02-05 Etienne Monier , Thomas Oberlin , Nathalie Brun , Xiaoyan Li , Marcel Tencé , Nicolas Dobigeon

Electrical impedance tomography (EIT) is a non-invasive imaging method with diverse applications, including medical imaging and non-destructive testing. The inverse problem of reconstructing internal electrical conductivity from boundary…

Image and Video Processing · Electrical Eng. & Systems 2025-07-08 Sara Sippola , Siiri Rautio , Andreas Hauptmann , Takanori Ide , Samuli Siltanen

The Electrical Resistance Tomography (ERT) technique is applied to the measurement of sheet conductance maps of both uniform and patterned conductive thin films. Images of the sheet conductance spatial distribution, and local conductivity…

Instrumentation and Detectors · Physics 2016-06-21 Alessandro Cultrera , Luca Callegaro

Electrical Impedance Tomography (EIT) is a powerful tool for non-destructive evaluation, state estimation, and process tomography - among numerous other use cases. For these applications, and in order to reliably reconstruct images of a…

Signal Processing · Electrical Eng. & Systems 2020-01-31 Danny Smyl , Dong Liu

Direct observation of nanoscale transformations in three dimensions (3D) is essential for understanding materials evolution under operating conditions, yet dynamic electron tomography remains limited by slow tilt series acquisition and by…

Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the boundary of a conductive medium (the data) are taken according to a prescribed protocol set and inverted to map the internal…

This work introduces a computational framework for applying absolute electrical impedance tomography to head imaging without accurate information on the head shape or the electrode positions. A library of fifty heads is employed to build a…

Numerical Analysis · Mathematics 2019-02-18 Valentina Candiani , Antti Hannukainen , Nuutti Hyvönen

In computed tomography (CT), the forward model consists of a linear Radon transform followed by an exponential nonlinearity based on the attenuation of light according to the Beer-Lambert Law. Conventional reconstruction often involves…

Computer Vision and Pattern Recognition · Computer Science 2026-03-25 Sara Fridovich-Keil , Fabrizio Valdivia , Gordon Wetzstein , Benjamin Recht , Mahdi Soltanolkotabi

The use of deep learning models within scientific experimental facilities frequently requires low-latency inference, so that, for example, quality control operations can be performed while data are being collected. Edge computing devices…

Image and Video Processing · Electrical Eng. & Systems 2019-11-15 Vibhatha Abeykoon , Zhengchun Liu , Rajkumar Kettimuthu , Geoffrey Fox , Ian Foster

Electrical Impedance Tomography can be cost-effective, portable, non-invasive imaging technique. It has preclinical and a few of them already proven industrial applications. This technique can only recover images of low spatial and contrast…

Instrumentation and Detectors · Physics 2023-04-17 Vaishali Sharma , Mayank Goswami

Regularization methods using prior knowledge are essential in solving ill-posed inverse problems such as Electrical Impedance Tomography (EIT). However, designing effective regularization and integrating prior information into EIT remains…

Computer Vision and Pattern Recognition · Computer Science 2025-04-08 Dong Liu , Yuanchao Wu , Bowen Tong , Jiansong Deng

A Jacobian-free inversion method is presented to accelerate Electrical Resistivity Tomography (ERT) for shallow aquifer characterization. The ERT problem typically implements the adjoint state method to efficiently compute Jacobian during…

Geophysics · Physics 2022-02-02 Jonghyun Lee