The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

Image and Video Processing · Electrical Eng. & Systems 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

In the presence of metal implants, metal artifacts are introduced to x-ray CT images. Although a large number of metal artifact reduction (MAR) methods have been proposed in the past decades, MAR is still one of the major problems in…

Medical Physics · Physics 2018-04-23 Yanbo Zhang , Hengyong Yu

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…

Computer Vision and Pattern Recognition · Computer Science 2018-08-07 Sungsoo Ha , Klaus Mueller

Computed tomography (CT) images are often severely corrupted by artifacts in the presence of metals. Existing supervised metal artifact reduction (MAR) approaches suffer from performance instability on known data due to their reliance on…

Computer Vision and Pattern Recognition · Computer Science 2025-12-11 Jie Wen , Chenhe Du , Xiao Wang , Yuyao Zhang

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

Image and Video Processing · Electrical Eng. & Systems 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

During the process of computed tomography (CT), metallic implants often cause disruptive artifacts in the reconstructed images, impeding accurate diagnosis. Several supervised deep learning-based approaches have been proposed for reducing…

Image and Video Processing · Electrical Eng. & Systems 2024-01-08 Xuan Liu , Yaoqin Xie , Songhui Diao , Shan Tan , Xiaokun Liang

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

Image and Video Processing · Electrical Eng. & Systems 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods which rely heavily on synthesized data for training. However, as synthesized data may not perfectly simulate the…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Haofu Liao , Wei-An Lin , Jianbo Yuan , S. Kevin Zhou , Jiebo Luo

Metal artefact reduction (MAR) techniques aim at removing metal-induced noise from clinical images. In Computed Tomography (CT), supervised deep learning approaches have been shown effective but limited in generalisability, as they mostly…

Computer Vision and Pattern Recognition · Computer Science 2020-04-21 Marta B. M. Ranzini , Irme Groothuis , Kerstin Kläser , M. Jorge Cardoso , Johann Henckel , Sébastien Ourselin , Alister Hart , Marc Modat

Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…

Image and Video Processing · Electrical Eng. & Systems 2020-09-17 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Lei Xing

The positive outcome of a trauma intervention depends on an intraoperative evaluation of inserted metallic implants. Due to occurring metal artifacts, the quality of this evaluation heavily depends on the performance of so-called Metal…

Image and Video Processing · Electrical Eng. & Systems 2021-12-07 Tristan M. Gottschalk , Andreas Maier , Florian Kordon , Björn W. Kreher

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

Medical Physics · Physics 2014-09-05 Yanbo Zhang , Xuanqian Mou

Filtered back projection (FBP) is the most widely used method for image reconstruction in X-ray computed tomography (CT) scanners. The presence of hyper-dense materials in a scene, such as metals, can strongly attenuate X-rays, producing…

Computer Vision and Pattern Recognition · Computer Science 2019-08-02 Muhammad Usman Ghani , W. Clem Karl

Metal artifact reduction (MAR) is one of the most important research topics in computed tomography (CT). With the advance of deep learning technology for image reconstruction,various deep learning methods have been also suggested for metal…

Image and Video Processing · Electrical Eng. & Systems 2020-07-08 Junghyun Lee , Jawook Gu , Jong Chul Ye

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

Image and Video Processing · Electrical Eng. & Systems 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

Metal implants can heavily attenuate X-rays in computed tomography (CT) scans, leading to severe artifacts in reconstructed images, which significantly jeopardize image quality and negatively impact subsequent diagnoses and treatment…

Medical Physics · Physics 2021-08-11 Tao Wang , Wenjun Xia , Yongqiang Huang , Huaiqiang Sun , Yan Liu , Hu Chen , Jiliu Zhou , Yi Zhang

Inspired by the great success of deep neural networks, learning-based methods have gained promising performances for metal artifact reduction (MAR) in computed tomography (CT) images. However, most of the existing approaches put less…

Image and Video Processing · Electrical Eng. & Systems 2025-08-04 Hong Wang , Yuexiang Li , Deyu Meng , Yefeng Zheng

Metal artifacts from high-attenuation implants severely degrade CT image quality, obscuring critical anatomical structures and posing a challenge for standard deep learning methods that require extensive paired training data. We propose a…

Computer Vision and Pattern Recognition · Computer Science 2026-04-08 Ahmet Rasim Emirdagi , Süleyman Aslan , Mısra Yavuz , Görkay Aydemir , Yunus Bilge Kurt , Nasrin Rahimi , Burak Can Biner , M. Akın Yılmaz

Current deep neural network based approaches to computed tomography (CT) metal artifact reduction (MAR) are supervised methods that rely on synthesized metal artifacts for training. However, as synthesized data may not accurately simulate…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Haofu Liao , Wei-An Lin , S. Kevin Zhou , Jiebo Luo

Recent CT Metal Artifacts Reduction (MAR) methods are often based on image-to-image convolutional neural networks for adjustment of corrupted sinograms or images themselves. In this paper, we are exploring the capabilities of a multi-domain…

Computer Vision and Pattern Recognition · Computer Science 2020-05-12 Artem Pimkin , Alexander Samoylenko , Natalia Antipina , Anna Ovechkina , Andrey Golanov , Alexandra Dalechina , Mikhail Belyaev