English
Related papers

Related papers: Proton Computed Tomography Image Reconstruction Ba…

200 papers

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…

Positron emission tomography (PET) is an important functional medical imaging technique often used in the evaluation of certain brain disorders, whose reconstruction problem is ill-posed. The vast majority of reconstruction methods in PET…

Image and Video Processing · Electrical Eng. & Systems 2023-06-09 Tin Vlašić , Tomislav Matulić , Damir Seršić

We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For…

Instrumentation and Detectors · Physics 2014-11-20 S. Braccini , A. Ereditato , I. Kreslo , U. Moser , C. Pistillo , S. Studer , P. Scampoli , A. Coray , E. Pedroni

Dose reduction in computed tomography (CT) is essential for decreasing radiation risk in clinical applications. Iterative reconstruction is one of the most promising ways to compensate for the increased noise due to reduction of photon…

Image and Video Processing · Electrical Eng. & Systems 2021-03-24 Zhuonan He , Yikun Zhang , Yu Guan , Shanzhou Niu , Yi Zhang , Yang Chen , Qiegen Liu

Computed tomography is a method for synthesizing volumetric or cross-sectional images of an object from a collection of projections. Popular reconstruction methods for computed tomography are based on idealized models and assumptions that…

Numerical Analysis · Mathematics 2022-03-03 Frederik H. Pedersen , Jakob S. Jørgensen , Martin S. Andersen

To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have…

We investigate possibilities to speed up iterative algorithms for non-blind image deconvolution. We focus on algorithms in which convolution with the point-spread function to be deconvolved is used in each iteration, and aim at accelerating…

Computer Vision and Pattern Recognition · Computer Science 2013-04-29 Martin Welk , Martin Erler

Computed Tomography (CT) is a widely used technology that requires compute-intense algorithms for image reconstruction. We propose a novel back-projection algorithm that reduces the projection computation cost to 1/6 of the standard…

Distributed, Parallel, and Cluster Computing · Computer Science 2019-09-09 Peng Chen , Mohamed Wahib , Shinichiro Takizawa , Ryousei Takano , Satoshi Matsuoka

Neutron Computed Tomography (CT) is an increasingly utilised non-destructive analysis tool in material science, palaeontology, and cultural heritage. With the development of new neutron imaging facilities (such as DINGO, ANSTO, Australia)…

Instrumentation and Detectors · Physics 2019-09-04 Jeremy M. C. Brown , Ulf Garbe , Daniele Pelliccia

X-Ray based computed tomography (CT) is a well-established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the…

Medical Physics · Physics 2023-04-26 Dinesh Kumar , Dilworth Y. Parkinson , Jeffrey J. Donatelli

A major challenge in computed tomography (CT) is to reduce X-ray dose to a low or even ultra-low level while maintaining the high quality of reconstructed images. We propose a new method for CT reconstruction that combines penalized…

Machine Learning · Statistics 2017-07-11 Xuehang Zheng , Zening Lu , Saiprasad Ravishankar , Yong Long , Jeffrey A. Fessler

Iterative methods for tomographic image reconstruction have great potential for enabling high quality imaging from low-dose projection data. The computational burden of iterative reconstruction algorithms, however, has been an impediment in…

Image and Video Processing · Electrical Eng. & Systems 2019-07-25 Kai Zhang , Alireza Entezari

With the availability of more powerful computers, iterative reconstruction algorithms are the subject of an ongoing work in the design of more efficient reconstruction algorithms for X-ray computed tomography. In this work, we show how two…

Computer Vision and Pattern Recognition · Computer Science 2017-03-14 D. Trinca , Y. Zhong

Background: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm…

Medical Physics · Physics 2026-02-04 Namhoon Kim , Ashwin Pananjady , Amir Pourmorteza , Sara Fridovich-Keil

Computed tomography (CT) scans offer a detailed, three-dimensional representation of patients' internal organs. However, conventional CT reconstruction techniques necessitate acquiring hundreds or thousands of x-ray projections through a…

Image and Video Processing · Electrical Eng. & Systems 2023-11-27 Chulong Zhang , Lin Liu , Jingjing Dai , Xuan Liu , Wenfeng He , Yinping Chan , Yaoqin Xie , Feng Chi , Xiaokun Liang

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

Medical Physics · Physics 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang

As the medical usage of computed tomography (CT) continues to grow, the radiation dose should remain at a low level to reduce the health risks. Therefore, there is an increasing need for algorithms that can reconstruct high-quality images…

Image and Video Processing · Electrical Eng. & Systems 2021-03-10 Davood Karimi , Rabab K. Ward

The major advantage of proton therapy over conventional radiotherapy is the dose deposition pattern, enabling precise coverage of the tumour volume while sparing nearby healthy tissues. However, accurate control of the proton beam range…

Medical Physics · Physics 2025-04-01 Magdalena Kołodziej

A method for photoacoustic tomography is presented that uses circular integrals of the acoustic wave for the reconstruction of a three-dimensional image. Image reconstruction is a two-step process: In the first step data from a stack of…

Numerical Analysis · Mathematics 2009-12-06 G. Zangerl , O. Scherzer , M. Haltmeier

Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly…