English
Related papers

Related papers: SNAF: Sparse-view CBCT Reconstruction with Neural …

200 papers

Multi-energy computed tomography (CT) with photon counting detectors (PCDs) enables spectral imaging as PCDs can assign the incoming photons to specific energy channels. However, PCDs with many spectral channels drastically increase the…

Image and Video Processing · Electrical Eng. & Systems 2022-11-03 Satu I. Inkinen , Mikael A. K. Brix , Miika T. Nieminen , Simon Arridge , Andreas Hauptmann

Cone-beam computed tomography (CBCT) is widely used in dental and maxillofacial imaging, but low-dose acquisition introduces strong, spatially varying noise that degrades soft-tissue visibility and obscures fine anatomical structures.…

Image and Video Processing · Electrical Eng. & Systems 2026-02-27 Khuram Naveed , Ruben Pauwels

Reconstructing dynamic, time-varying scenes with computed tomography (4D-CT) is a challenging and ill-posed problem common to industrial and medical settings. Existing 4D-CT reconstructions are designed for sparse sampling schemes that…

Image and Video Processing · Electrical Eng. & Systems 2021-04-26 Albert W. Reed , Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley , Jingu Kang , Suren Jayasuriya

Cone-beam computed tomography (CBCT) is an important tool facilitating computer aided interventions, despite often suffering from artifacts that pose challenges for accurate interpretation. While the degraded image quality can affect…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

In this paper, we investigate image reconstruction for dynamic Computed Tomography. The motion of the target with respect to the measurement acquisition rate leads to highly resolved in time but highly undersampled in space measurements.…

Image and Video Processing · Electrical Eng. & Systems 2025-06-27 Pablo Arratia , Matthias Ehrhardt , Lisa Kreusser

This is a preprint. The latest version has been published here: https://pubs.rsna.org/doi/10.1148/ryai.230275 Purpose: Sparse-view computed tomography (CT) is an effective way to reduce dose by lowering the total number of views acquired,…

Image and Video Processing · Electrical Eng. & Systems 2024-08-09 Johannes Thalhammer , Manuel Schultheiss , Tina Dorosti , Tobias Lasser , Franz Pfeiffer , Daniela Pfeiffer , Florian Schaff

The diagnostic quality of computed tomography (CT) scans is usually restricted by the induced patient dose, scan speed, and image quality. Sparse-angle tomographic scans reduce radiation exposure and accelerate data acquisition, but suffer…

Computer Vision and Pattern Recognition · Computer Science 2023-08-10 Fabian Wagner , Mareike Thies , Noah Maul , Laura Pfaff , Oliver Aust , Sabrina Pechmann , Christopher Syben , Andreas Maier

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

Cone-beam breast computed tomography (CT) provides true 3D breast images with isotropic resolution and high-contrast information, detecting calcifications as small as a few hundred microns and revealing subtle tissue differences. However,…

Medical Physics · Physics 2019-12-18 Wenxiang Cong , Hongming Shan , Xiaohua Zhang , Shaohua Liu , Ruola Ning , Ge Wang

Unlike previous works, this open data collection consists of X-ray cone-beam (CB) computed tomography (CT) datasets specifically designed for machine learning applications and high cone-angle artefact reduction. Forty-two walnuts were…

Image and Video Processing · Electrical Eng. & Systems 2020-09-07 Henri Der Sarkissian , Felix Lucka , Maureen van Eijnatten , Giulia Colacicco , Sophia Bethany Coban , Kees Joost Batenburg

In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…

Computer Vision and Pattern Recognition · Computer Science 2024-09-20 Joonil Hwang , Sangjoon Park , NaHyeon Park , Seungryong Cho , Jin Sung Kim

For conventional computed tomography (CT) image reconstruction tasks, the most popular method is the so-called filtered-back-projection (FBP) algorithm. In it, the acquired Radon projections are usually filtered first by a ramp kernel…

Medical Physics · Physics 2018-07-06 Yongshuai Ge , Qiyang Zhang , Zhanli Hu , Jianwei Chen , Wei Shi , Hairong Zheng , Dong Liang

Computed tomography has propelled scientific advances in fields from biology to materials science. This technology allows for the elucidation of 3-dimensional internal structure by the attenuation of x-rays through an object at different…

Computer Vision and Pattern Recognition · Computer Science 2022-11-02 Rey Mendoza , Minh Nguyen , Judith Weng Zhu , Vincent Dumont , Talita Perciano , Juliane Mueller , Vidya Ganapati

Three-dimensional (3D) and dynamic 3D+time (4D) reconstruction of coronary arteries from X-ray coronary angiography (CA) has the potential to improve clinical procedures. However, there are multiple challenges to be addressed, most notably,…

Image and Video Processing · Electrical Eng. & Systems 2025-07-28 Kirsten W. H. Maas , Danny Ruijters , Nicola Pezzotti , Anna Vilanova

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…

This study introduces a novel reconstruction method for dental cone-beam computed tomography (CBCT), focusing on effectively reducing metal-induced artifacts commonly encountered in the presence of prevalent metallic implants. Despite…

Computer Vision and Pattern Recognition · Computer Science 2023-07-28 Hyoung Suk Park , Kiwan Jeon , Jin Keun Seo

Recently, compressed sensing (CS) computed tomography (CT) using sparse projection views has been extensively investigated to reduce the potential risk of radiation to patient. However, due to the insufficient number of projection views, an…

Computer Vision and Pattern Recognition · Computer Science 2016-11-28 Yo Seob Han , Jaejun Yoo , Jong Chul Ye

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low…

Medical Physics · Physics 2015-06-03 Xun Jia , Zhen Tian , Yifei Lou , Jan-Jakob Sonke , Steve B. Jiang

Metal artifacts in computed tomography (CT) arise from a mismatch between physics of image formation and idealized assumptions during tomographic reconstruction. These artifacts are particularly strong around metal implants, inhibiting…

Image and Video Processing · Electrical Eng. & Systems 2019-09-20 Jan-Nico Zaech , Cong Gao , Bastian Bier , Russell Taylor , Andreas Maier , Nassir Navab , Mathias Unberath

Computed tomography (CT) is increasingly being used for cancer screening, such as early detection of lung cancer. However, CT studies have varying pixel spacing due to differences in acquisition parameters. Thick slice CTs have lower…

Computer Vision and Pattern Recognition · Computer Science 2018-07-19 Meng Li , Shiwen Shen , Wen Gao , William Hsu , Jason Cong
‹ Prev 1 3 4 5 6 7 10 Next ›