English
Related papers

Related papers: Metal-conscious Embedding for CBCT Projection Inpa…

200 papers

During orthopaedic surgery, the inserting of metallic implants or screws are often performed under mobile C-arm systems. Due to the high attenuation of metals, severe metal artifacts occur in 3D reconstructions, which degrade the image…

Image and Video Processing · Electrical Eng. & Systems 2022-09-21 Siyuan Mei , Fuxin Fan , Andreas Maier

Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…

Image and Video Processing · Electrical Eng. & Systems 2023-10-10 Harshit Agrawal , Ari Hietanen , Simo Särkkä

A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…

Image and Video Processing · Electrical Eng. & Systems 2022-03-24 Haofu Liao , Wei-An Lin , Zhimin Huo , Levon Vogelsang , William J. Sehnert , S. Kevin Zhou , Jiebo Luo

In computer tomography, due to the presence of metal implants in the patient body, reconstructed images will suffer from metal artifacts. In order to reduce metal artifacts, metals are typically removed in projection images. Therefore, the…

Computer Vision and Pattern Recognition · Computer Science 2020-05-05 Lin Yuan , Yixing Huang , Andreas Maier

This study introduces a novel reconstruction method for dental cone-beam computed tomography (CBCT), focusing on effectively reducing metal-induced artifacts commonly encountered in the presence of prevalent metallic implants. Despite…

Computer Vision and Pattern Recognition · Computer Science 2023-07-28 Hyoung Suk Park , Kiwan Jeon , Jin Keun Seo

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…

Image and Video Processing · Electrical Eng. & Systems 2022-02-09 Chang Min Hyun , Taigyntuya Bayaraa , Hye Sun Yun , Tae Jun Jang , Hyoung Suk Park , Jin Keun Seo

The positive outcome of a trauma intervention depends on an intraoperative evaluation of inserted metallic implants. Due to occurring metal artifacts, the quality of this evaluation heavily depends on the performance of so-called Metal…

Image and Video Processing · Electrical Eng. & Systems 2021-12-07 Tristan M. Gottschalk , Andreas Maier , Florian Kordon , Björn W. Kreher

In several image acquisition and processing steps of X-ray radiography, knowledge of the existence of metal implants and their exact position is highly beneficial (e.g. dose regulation, image contrast adjustment). Another application which…

Image and Video Processing · Electrical Eng. & Systems 2022-03-18 Fuxin Fan , Ludwig Ritschl , Marcel Beister , Ramyar Biniazan , Björn Kreher , Tristan M. Gottschalk , Steffen Kappler , Andreas Maier

Metal artifacts in computed tomography (CT) arise from a mismatch between physics of image formation and idealized assumptions during tomographic reconstruction. These artifacts are particularly strong around metal implants, inhibiting…

Image and Video Processing · Electrical Eng. & Systems 2019-09-20 Jan-Nico Zaech , Cong Gao , Bastian Bier , Russell Taylor , Andreas Maier , Nassir Navab , Mathias Unberath

Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…

Medical Physics · Physics 2014-09-05 Yanbo Zhang , Xuanqian Mou

Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or…

Computer Vision and Pattern Recognition · Computer Science 2024-03-28 Mohammadreza Amirian , Daniel Barco , Ivo Herzig , Frank-Peter Schilling

Cone-beam computed tomography (CBCT) is an important tool facilitating computer aided interventions, despite often suffering from artifacts that pose challenges for accurate interpretation. While the degraded image quality can affect…

Image and Video Processing · Electrical Eng. & Systems 2024-07-02 Maximilian E. Tschuchnig , Philipp Steininger , Michael Gadermayr

During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides…

Computer Vision and Pattern Recognition · Computer Science 2022-01-20 Mareike Thies , Jan-Nico Zäch , Cong Gao , Russell Taylor , Nassir Navab , Andreas Maier , Mathias Unberath

Since the invention of modern CT systems, metal artifacts have been a persistent problem. Due to increased scattering, amplified noise, and insufficient data collection, it is more difficult to suppress metal artifacts in cone-beam CT,…

Medical Physics · Physics 2023-10-27 Tianling Lyu , Zhan Wu , Gege Ma , Chen Jiang , Xinyun Zhong , Yan Xi , Yang Chen , Wentao Zhu

Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…

Image and Video Processing · Electrical Eng. & Systems 2021-03-09 Yuanyuan Lyu , Wei-An Lin , Haofu Liao , Jingjing Lu , S. Kevin Zhou

Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…

Cone-beam computed tomography (CBCT) is a widely used 3D imaging technique in dentistry, offering high-resolution images while minimising radiation exposure for patients. However, CBCT is highly susceptible to artefacts arising from…

Computer Vision and Pattern Recognition · Computer Science 2026-03-09 Susanne Schaub , Florentin Bieder , Matheus L. Oliveira , Yulan Wang , Dorothea Dagassan-Berndt , Michael M. Bornstein , Philippe C. Cattin

Sparse-view computed tomography (CT) has been adopted as an important technique for speeding up data acquisition and decreasing radiation dose. However, due to the lack of sufficient projection data, the reconstructed CT images often…

Image and Video Processing · Electrical Eng. & Systems 2023-06-27 Hong Wang , Minghao Zhou , Dong Wei , Yuexiang Li , Yefeng Zheng

The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…

Image and Video Processing · Electrical Eng. & Systems 2021-09-29 Lequan Yu , Zhicheng Zhang , Xiaomeng Li , Hongyi Ren , Wei Zhao , Lei Xing

During the computed tomography (CT) imaging process, metallic implants within patients often cause harmful artifacts, which adversely degrade the visual quality of reconstructed CT images and negatively affect the subsequent clinical…

Image and Video Processing · Electrical Eng. & Systems 2022-12-27 Hong Wang , Yuexiang Li , Haimiao Zhang , Deyu Meng , Yefeng Zheng