English
Related papers

Related papers: Fluorescence Suppressor Gas Electron Multiplier (F…

200 papers

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…

Instrumentation and Detectors · Physics 2026-05-29 Sachin Rana , Md. Kaosor Ali Mondal , Poojan Angiras , Amal Sarkar

Gaseous detectors are used in both low energy and high energy physics experiments. The present day gaseous detectors, i.e., the Micro-Pattern gaseous detectors (MPGD) are more efficient and fast. Gas Electron multiplier (GEM) is quite well…

Instrumentation and Detectors · Physics 2017-08-08 Deb Sankar Bhattacharya , P K Sahu , Sagarika Swain , Sanjib K Sahu

Dual-energy subtraction imaging (DES) is a method to improve the detectability of contrast agents over a lumpy background. Two images, acquired at x-ray energies above and below an absorption edge of the agent material, are logarithmically…

The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the…

Instrumentation and Detectors · Physics 2022-09-16 Marius Mæhlum Halvorsen , Victor Coco , Evangelos Leonidas Gkougkousis , Paula Collins , Olivier Girard

A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…

Instrumentation and Detectors · Physics 2009-09-30 V. Inshakov , V. Kryshkin , N. Kuzmin , V. Skvortsov , S. Sychkov , A. Sytin

The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for…

Instrumentation and Detectors · Physics 2009-09-29 S. Lami , G. Latino , E. Oliveri , L. Ropelewski , N. Turini

Electroluminescence produced during avalanche development in gaseous avalanche detectors is an useful information for triggering, calorimetry and tracking in gaseous detectors. Noble gases present high electroluminescence yields, emitting…

Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent…

The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…

Instrumentation and Detectors · Physics 2021-12-02 Othmane Bouhali , Kerstin Hoepfner , Francesco Ivone , Teruki Kamon , Henning Keller , Shivali Malhotra , Badriya Al Rashdi

Preliminary results on the development of a separation method for Cerenkov (CL) and fluorescence (FL) light from EAS are shown. The results are based on the measurement of attenuation coefficients of CL and FL for different filters. A total…

We report the status of R&D on large triple-GEM detectors for a forward tracker (FT) in an experiment at a future Electron Ion Collider (EIC) that will improve our understanding of QCD. We have designed a detector prototype specifically…

Instrumentation and Detectors · Physics 2016-11-17 Aiwu Zhang , Vallary Bhopatkar , Marcus Hohlmann , Xinzhan Bai , Kondo Gnanvo , Nilanga K. Liyanage , Matt Posik , Bernd Surrow

The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode…

Instrumentation and Detectors · Physics 2017-03-08 E. Erdal , L. Arazi , M. Rappaport , S. Shchemelinin , D. Vartsky , A. Breskin

We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…

Instrumentation and Detectors · Physics 2017-10-11 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas…

Instrumentation and Detectors · Physics 2015-06-22 S. Biswas , A. Abuhoza , U. Frankenfeld , J. Hehner , C. J. Schmidt , H. R. Schmidt , M. Traeger , S. Colafranceschi , A. Marinov , A. Sharma

The origin of an anomalous excess of high-energy (about 100 GeV and higher) positrons in cosmic rays is one of the rare problems in this field, which is proposed to be solved with dark matter (DM). Attempts to solve this problem are faced…

High Energy Astrophysical Phenomena · Physics 2023-10-12 Ramin Barak , Konstantin Belotsky , Ekaterina Shlepkina

Gas Electron Multiplier (GEM) detectors, typically featuring a standard pitch size of 140 $\mu$m and an inner hole diameter of 50 $\mu$m, are extensively utilized in high-energy physics experiments for tracking, triggering, and timing…

High Energy Physics - Experiment · Physics 2025-05-07 Rajiv Gupta , Gauri Devi , Sunidhi Saxena , Arpit Singh , Ajay Kumar

We succeeded in modifying and controlling the electrical resistance of a standard High Pressure Laminate (HPL) panel through the use of a Gas Electron Multiplier (GEM) foil that has been embedded into the bulk of the HPL plate itself.…

Instrumentation and Detectors · Physics 2018-03-22 P. Vitulo

Gamma Ray Bursts are being searched in many ground based experiments detecting the high energy component (GeV $\div$ TeV energy range) of the photon bursts. In this paper, Fluorescence Detectors are considered as possible candidate devices…

Astrophysics · Physics 2013-06-11 R. Aloisio , D. Boncioli , A. F. Grillo , C. Macolino , S. Petrera , P. Privitera , V. Rizi , F. Salamida

The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.

Instrumentation and Detectors · Physics 2014-04-01 R. Oliveira , S. Franchino , V. Peskov

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…

Instrumentation and Detectors · Physics 2012-08-31 Serge Duarte Pinto , Philippe Carrière , Jens Spanggaard , Gerard Tranquille
‹ Prev 1 4 5 6 7 8 10 Next ›