Related papers: Synthetic Low-Field MRI Super-Resolution Via Neste…
Low-field (LF) magnetic resonance imaging (MRI) improves accessibility and reduces costs but generally has lower signal-to-noise ratios and degraded contrast compared to high field (HF) MRI, limiting its clinical utility. Simulating LF MRI…
Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, key barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long…
Low-field magnetic resonance imaging (MRI) offers a cost-effective alternative for medical imaging in resource-limited settings. However, its widespread adoption is hindered by two key challenges: prolonged scan times and reduced image…
Ultra-low-field (ULF) MRI offers portable and accessible neuroimaging but suffers from reduced signal-to-noise ratio and limited spatial resolution compared to high-field (HF) systems. Acquiring paired ULF-HF data for supervised enhancement…
Single image super-resolution (SISR) is the task of inferring a high-resolution image from a single low-resolution image. Recent research on super-resolution has achieved great progress due to the development of deep convolutional neural…
Ultra-low-field (ULF, <0.1 T) magnetic resonance imaging (MRI) systems offer advantages in cost, portability, and accessibility, but their current utility is still limited by low signal-to-noise ratio (SNR). Deep learning (DL)-based…
The recent introduction of portable, low-field MRI (LF-MRI) into the clinical setting has the potential to transform neuroimaging. However, LF-MRI is limited by lower resolution and signal-to-noise ratio, leading to incomplete…
Background: Three-dimensional, whole heart, balanced steady state free precession (WH-bSSFP) sequences provide delineation of intra-cardiac and vascular anatomy. However, they have long acquisition times. Here, we propose significant speed…
Recent research has explored using neural networks to reconstruct undersampled magnetic resonance imaging (MRI) data. Because of the complexity of the artifacts in the reconstructed images, there is a need to develop task-based approaches…
Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B1+) inhomogeneities,…
Typical Magnetic Resonance Imaging (MRI) scan may take 20 to 60 minutes. Reducing MRI scan time is beneficial for both patient experience and cost considerations. Accelerated MRI scan may be achieved by acquiring less amount of k-space data…
Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) offers an elevated signal-to-noise ratio (SNR), enabling exceptionally high spatial resolution that benefits both clinical diagnostics and advanced research. However, the jump to higher…
In order to address the issue that medical image would suffer from severe blurring caused by the lack of high-frequency details in the process of image super-resolution reconstruction, a novel medical image super-resolution method based on…
Compressed Sensing MRI reconstructs images of the body's internal anatomy from undersampled measurements, thereby reducing scan time. Recently, deep learning has shown great potential for reconstructing high-fidelity images from highly…
Ultra-low-field (ULF) MRI offers portable and low-cost imaging but suffers from poor image quality. To address this, we present our submission to the 2025 ULF Enhancement Challenge (ULF-EnC), where the goal is to synthesise high-field-like…
We present an unsupervised single image bidirectional Magnetic Resonance Image (MRI) synthesizer that synthesizes an Ultra-Low Field (ULF) like image from a High-Field (HF) magnitude image and vice-versa. Unlike existing MRI synthesis…
Synthesizing high-quality images from low-field MRI holds significant potential. Low-field MRI is cheaper, more accessible, and safer, but suffers from low resolution and poor signal-to-noise ratio. This synthesis process can reduce…
Light field microscopy (LFM) has been widely utilized in various fields for its capability to efficiently capture high-resolution 3D scenes. Despite the rapid advancements in neural representations, there are few methods specifically…
Coherent imaging systems like synthetic aperture radar are susceptible to multiplicative noise that makes applications like automatic target recognition challenging. In this paper, NeighCNN, a deep learning-based speckle reduction algorithm…
Magnetic resonance imaging (MRI) super-resolution (SR) methods that computationally enhance low-resolution acquisitions to approximate high-resolution quality offer a compelling alternative to expensive high-field scanners. In this work we…