Related papers: Analytical Estimation of Beamforming Speed-of-Soun…
In ultrasound beamforming, focusing time delays are typically computed with a spatially constant speed-of-sound (SoS) assumption. A mismatch between beamforming and true medium SoS then leads to aberration artifacts. Other imaging…
Most ultrasound (US) imaging techniques use spatially-constant speed-of-sound (SoS) values for beamforming. Having a discrepancy between the actual and used SoS value leads to aberration artifacts, e.g., reducing the image resolution, which…
For beamforming ultrasound (US) signals, typically a spatially constant speed-of-sound (SoS) is assumed to calculate delays. As SoS in tissue may vary relatively largely, this approximation may cause wavefront aberrations, thus degrading…
Conventional ultrasound (US) imaging employs the delay and sum (DAS) receive beamforming with dynamic receive focus for image reconstruction due to its simplicity and robustness. However, the DAS beamforming follows a geometrical method of…
Accurate speed-of-sound (SoS) estimation is crucial for ultrasound image formation, yet conventional systems often rely on an assumed value for imaging. We propose to leverage conventional image analysis techniques and metrics as a novel…
Photoacoustic (PA) image reconstruction involves acoustic inversion that necessitates the specification of the speed of sound (SoS) within the medium of propagation. Due to the lack of information on the spatial distribution of the SoS…
Imaging methods based on array signal processing often require a fixed propagation speed of the medium, or speed of sound (SoS) for methods based on acoustic signals. The resolution of the images formed using these methods is strongly…
Speed-of-sound (SoS) is an emerging ultrasound contrast modality, where pulse-echo techniques using conventional transducers offer multiple benefits. For estimating tissue SoS distributions, spatial domain reconstruction from relative…
Recent ultrasound imaging modalities based on ultrasound computed tomography indicate a huge potential to detect pathologies is tissue due to altered biomechanical properties. Especially the imaging of speed-of-sound (SoS) distribution in…
The purpose of this work is to demonstrate a robust and clinically validated method for correcting sound speed aberrations in medical ultrasound. We propose a correction method that calculates focusing delays directly from the observed…
Computed ultrasound tomography in echo mode (CUTE) allows determining the spatial distribution of speed-of-sound (SoS) inside tissue using handheld pulse-echo ultrasound (US). This technique is based on measuring the changing phase of…
In pulse-echo ultrasound, aberration often degrades image quality when beamforming does not account for wavefront distortions. To address this issue, local sound speed estimators have been developed in the past decade for distributed…
Speed-of-sound (SoS) is a biomechanical characteristic of tissue, and its imaging can provide a promising biomarker for diagnosis. Reconstructing SoS images from ultrasound acquisitions can be cast as a limited-angle computed-tomography…
Speed-of-sound (SoS) is a novel imaging biomarker for assessing biomechanical characteristics of soft tissues. SoS imaging in pulse-echo mode using conventional ultrasound systems with hand-held transducers has the potential to enable new…
The standard technique used by commercial medical ultrasound systems to form B-mode images is delay and sum (DAS) beamforming. However, DAS often results in limited image resolution and contrast, which are governed by the center frequency…
In most photoacoustic (PA) measurements, variations in speed-of-sound (SOS) of the subject are neglected under the assumption of acoustic homogeneity. Biological tissue with spatially heterogeneous SOS cannot be accurately reconstructed…
Shear-wave Elastography Imaging (SWEI) is a noninvasive imaging modality that provides tissue elasticity information by measuring the travelling speed of an induced shear-wave. It is commercially available on clinical ultrasound scanners…
Sound speed heterogeneities can create aberrations in B-mode ultrasound images by inducing tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. By using the Fourier split-step method to…
Delay-and-sum (DAS) is the most widespread digital beamformer in high-frame-rate ultrasound imaging. Its implementation is simple and compatible with real-time applications. In this viewpoint article, we describe the fundamentals of DAS…
Computed ultrasound tomography in echo mode generates maps of tissue speed of sound (SoS) from the shift of echoes when detected under varying steering angles. It solves a linearized inverse problem that requires regularization to…