English
Related papers

Related papers: Simultaneous MMC readout using a tailored {\mu}MUX…

200 papers

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of Transition Edge Sensors. DfMux has been used by several…

Quantum computers based on solid state qubits have been a subject of rapid development in recent years. In current Noisy Intermediate-Scale Quantum (NISQ) technology, each quantum device is controlled and characterised though a dedicated…

Ultra-sensitive cryogenic calorimeters have become a favored technology with widespread application where eV-scale energy resolutions are needed. In this article, we characterize the performance of an X-ray magnetic microcalorimeter (MMC)…

High Energy Physics - Experiment · Physics 2025-01-16 Francesco Toschi , Benedikt Maier , Greta Heine , Torben Ferber , Sebastian Kempf , Markus Klute , Belina von Krosigk

CMB-S4 is the fourth-generation ground-based cosmic microwave background project, designed to probe the early universe and cosmic inflation. CMB-S4 would achieve its science goals in part by dramatically increasing the number of transition…

Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to…

The demand for a large number of readout channels has been a limiting factor for the application of Micro-pattern Gaseous Detectors (MPGDs) in achieving higher spatial resolution and larger detection areas. This challenge is further…

Instrumentation and Detectors · Physics 2025-05-22 Yu Wang , Shubin Liu , Hao Zhuang , Zhengwu Ding , Zhihang Yao , Changqing Feng , Zhiyong Zhang

More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels.…

Instrumentation and Detectors · Physics 2018-03-14 A. C. Ezeribe , M. Robinson , N. Robinson , A. Scarff , N. J. C. Spooner , L. Yuriev

Advanced ACTPol is an instrument upgrade for the six-meter Atacama Cosmology Telescope (ACT) designed to measure the cosmic microwave background (CMB) temperature and polarization with arcminute-scale angular resolution. To achieve its…

Recently, ultrasensitive calorimeters have been proposed as a resource-efficient solution for multiplexed qubit readout in superconducting large-scale quantum processors. However, experiments demonstrating frequency multiplexing of these…

Solid-state quantum computers require classical electronics to control and readout individual qubits and to enable fast classical data processing [1-3]. Integrating both subsystems at deep cryogenic temperatures [4], where solid-state…

A digital frequency multiplexing (DfMUX) system has been developed and used to tune large arrays of transition edge sensor (TES) bolometers read out with SQUID arrays for mm-wavelength cosmology telescopes. The DfMUX system multiplexes the…

Instrumentation and Methods for Astrophysics · Physics 2015-05-14 K. MacDermid , P. Hyland , F. Aubin , E. Bissonnette , M. Dobbs , J. Hubmayr , G. Smecher , S. Warraich

A microwave SQUID multiplexer ($\mu$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer…

In this paper, we present a reconfigurable multiplex (MUX) setup that increases the throughput of electrical characterisation at cryogenic temperature. The setup separates the MUX circuitry from quantum device under test (qDUT), allowing…

Mesoscale and Nanoscale Physics · Physics 2024-03-29 Xinya Bian , Hannah J Joyce , Charles G Smith , Michael J Kelly , G Andrew D Briggs , Jan A Mol

Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature…

Research in the field of low-temperature electronics is limited by the small number of electrical contacts available on cryogenic set ups. This not only restricts the number of devices that can be fabricated, but also the device and circuit…

Mesoscale and Nanoscale Physics · Physics 2014-07-23 H. Al-Taie , L. W. Smith , B. Xu , P. See , J. P. Griffiths , H. E. Beere , G. A. C. Jones , D. A. Ritchie , M. J. Kelly , C. G. Smith

Within this proceeding, we introduce the U-Board platform, a versatile platform for signal generation, acquisition and processing, based on a heterogenous processing architecture. Based on this platform we present a readout for Microwave…

Instrumentation and Methods for Astrophysics · Physics 2023-10-10 Gerrit Grutzeck , Ingo Krämer , Miroslaw Ciechanowicz , Nicolas Reyes , Carsten König , Andrey Baryshev , Stephen Yates , Bernd Klein

We present an advanced model for describing the readout power dependence of the resonance characteristics of a microwave SQUID multiplexer. Our model proves valid for SQUID screening parameters up to $\beta_\mathrm{L}<1$, hence covering the…

Instrumentation and Detectors · Physics 2026-04-09 Martin Neidig , Mathias Wegner , Sebastian Kempf

We have developed a non-destructive readout system that uses a floating-gate amplifier on a thick, fully depleted charge coupled device (CCD) to achieve ultra-low readout noise of 0.068 e- rms/pix. This is the first time that discrete…

The precision of existing decay data of radionuclides for activity determination is often a limitation for actual applications in science, society, and industry. For this reason, the EMPIR project PrimA-LTD aims to introduce an advanced…

Instrumentation and Detectors · Physics 2023-12-18 Michael Müller , Matias Rodrigues , Jörn Beyer , Martin Loidl , Sebastian Kempf

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count,…