English
Related papers

Related papers: Benchtop magnetic shielding for benchmarking atomi…

200 papers

We report on the design, construction, and performance of a compact magnetic shield that facilitates a controlled, low-noise environment for experiments with ultracold atomic gases. The shield was designed to passively attenuate external…

Instrumentation and Detectors · Physics 2019-12-03 Arturo Farolfi , Dimitrios Trypogeorgos , Giacomo Colzi , Eleonora Fava , Giacomo Lamporesi , Gabriele Ferrari

Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field…

Magnetically-sensitive experiments and newly-developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power and cost.…

Magnetic shields that use both active and passive components to enable the generation of a tailored low-field environment are required for many applications in science, engineering, and medical imaging. Until now, accurate field nulling, or…

Applied Physics · Physics 2020-11-09 M. Packer , P. J. Hobson , N. Holmes , J. Leggett , P. Glover , M. J. Brookes , R. Bowtell , T. M. Fromhold

Hybrid magnetic shields with both active field generating components and high-permeability magnetic shielding are increasingly needed for a variety of technologies and experiments that require precision-controlled magnetic field…

Applied Physics · Physics 2021-06-04 M. Packer , P. J. Hobson , N. Holmes , J. Leggett , P. Glover , M. J. Brookes , R. Bowtell , T. M. Fromhold

A passive magnetic shield was designed and constructed for magnetometer tests for the future neutron electric dipole moment experiment at TRIUMF. The axial shielding factor of the magnetic shield was measured using a magnetometer based on…

We present a magnetically shielded environment with a damping factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an…

Ferrite materials provide magnetic shielding performance similar to commonly used high permeability metals but have lower intrinsic magnetic noise generated by thermal Johnson currents due to their high electrical resistivity. Measurements…

Atomic Physics · Physics 2007-07-26 T. W. Kornack , S. J. Smullin , S. -K. Lee , M. V. Romalis

A three-step model for calculating the magnetic field generated by coils inside cuboid-shaped shields like magnetically shielded rooms (MSRs) is presented. The shield is modelled as two parallel plates of infinite width and one tube of…

Applied Physics · Physics 2020-11-17 Tianhao Liu , Allard Schnabel , Jens Voigt , Zhiyin Sun , Liyi Li

Well controlled and highly stable magnetic fields are desired for a wide range of applications in physical research, including quantum metrology, sensing, information processing, and simulation. Here we introduce a low-cost hybrid assembly…

Quantum Physics · Physics 2018-12-21 Frederick Hakelberg , Philip Kiefer , Matthias Wittemer , Tobias Schaetz , Ulrich Warring

We report on a single-channel rubidium radio-frequency atomic magnetometer operating in un-shielded environments and near room temperature with a measured sensitivity of 130 fT/\sqrt{Hz}. We demonstrate consistent, narrow-bandwidth…

Atomic Physics · Physics 2018-08-27 Cameron Deans , Luca Marmugi , Ferruccio Renzoni

A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold…

We present a novel Active Magnetic Shield (AMS), designed and implemented for the n2EDM experiment at the Paul Scherrer Institute. The experiment will perform a high-sensitivity search for the electric dipole moment of the neutron.…

A passive superconducting shield was proposed earlier to realize a high-field (3-4 T) septum magnet for the Future Circular Collider. This paper presents the experimental results of a potential shield material, a NbTi/Nb/Cu multilayer…

Recent advances in the understanding and control of quantum technologies, such as those based on cold atoms, have resulted in devices with extraordinary metrological sensitivities. To realise this potential outside of a lab environment the…

The n2EDM experiment at the Paul Scherrer Institute aims to conduct a high-sensitivity search for the electric dipole moment of the neutron. Magnetic stability and control are achieved through a combination of passive shielding, provided by…

We describe an experimental study of spin-projection noise in a high sensitivity alkali-metal magnetometer. We demonstrate a four-fold improvement in the measurement bandwidth of the magnetometer using continuous quantum non-demolition…

Quantum Physics · Physics 2010-01-18 V. Shah , G. Vasilakis , M. V. Romalis

There is an increasing need to shield beams and accelerator elements from stray magnetic fields. The application of magnetic shielding in linear colliders is discussed. The shielding performance of soft iron and mu-metal is measured for…

Accelerator Physics · Physics 2021-02-03 C. Gohil , P. N. Burrows , N. Blaskovic Kraljevic , D. Schulte , B. Heilig

The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied. It is found that for concentric cylindrical or spherical shells of high permeability material, higher order…

Instrumentation and Detectors · Physics 2013-10-31 C. P. Bidinosti , J. W. Martin

High-permeability magnetic shields generate magnetic field noise that can limit the sensitivity of modern precision measurements. We show that calculations based on the fluctuation-dissipation theorem allow quantitative evaluation of…

Instrumentation and Detectors · Physics 2009-11-13 S. -K. Lee , M. V. Romalis