We present the design and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) that uses adiabatic demagnetization of electron magnetic moments for controlling its operating temperature in the range between 30 mK…

Instrumentation and Detectors · Physics 2024-01-30 Taner Esat , Peter Borgens , Xiaosheng Yang , Peter Coenen , Vasily Cherepanov , Andrea Raccanelli , F. Stefan Tautz , Ruslan Temirov

We present the design and operation of a very-low temperature Scanning Tunneling Microscope (STM) working at $60 mK$ in a dilution refrigerator. The STM features both atomic resolution and micron-sized scanning range at low temperature.…

Mesoscale and Nanoscale Physics · Physics 2009-10-31 N. Moussy , H. Courtois , B. Pannetier

We have designed and built a scanning tunneling microscope (STM) setup for operation at millikelvin temperatures in ultra high vacuum. A compact cryostat with an integrated dilution refrigerator has been built, that allows measurements at a…

Instrumentation and Detectors · Physics 2018-12-05 Timofey Balashov , Michael Meyer , Wulf Wulfhekel

Recent advances in increasing the spectroscopic energy resolution in scanning tunneling microscopy (STM) have been achieved by integrating electron spin resonance (ESR) with STM. Here, we demonstrate the design and performance of a…

We describe a scanning tunneling microscope (STM) that operates at magnetic fields up to 22 Tesla and temperatures down to 80 mK. We discuss the design of the STM head, with an improved coarse approach, the vibration isolation system, and…

We describe the construction and performance of a scanning tunneling microscope (STM) capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T)…

Instrumentation and Detectors · Physics 2013-10-04 Shashank Misra , Brian B. Zhou , Ilya K. Drozdov , Jungpil Seo , Andras Gyenis , Simon C. J. Kingsley , Howard Jones , Ali Yazdani

We describe a compact ultra-high vacuum (UHV) scanning tunneling microscope (STM) system that does not need any external supply of cooling liquids. It achieves temperatures down to 1.5 K and a z-noise down to 300 fmRMS for the frequency…

We constructed a dilution-refrigerator (DR) based ultra-low temperature scanning tunneling microscope (ULT-STM) which works at temperatures down to 30 mK, in magnetic fields up to 6 T and in ultrahigh vacuum (UHV). Besides these extreme…

Superconductivity · Physics 2009-11-13 H. Kambara , T. Matsui , Y. Niimi , H. Fukuyama

We describe the development and performance of an ultra-high vacuum scanning tunneling microscope working under combined extreme conditions of ultra-low temperatures and high magnetic fields. We combined a top-loading dilution refrigerator…

Instrumentation and Detectors · Physics 2018-10-17 T. Machida , Y. Kohsaka , T. Hanaguri

We describe the design and performance of a scanning tunneling microscope (STM) which operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution…

We describe the design, construction, and performance of an ultra-low temperature, high-field scanning tunneling microscope (STM) with two independent tips. The STM is mounted on a dilution refrigerator and operates at a base temperature of…

Mesoscale and Nanoscale Physics · Physics 2015-06-17 A. Roychowdhury , M. A. Gubrud , R. Dana , J. R. Anderson , C. J. Lobb , F. C. Wellstood , M. Dreyer

We present a probe-type scanning tunneling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature…

Instrumentation and Detectors · Physics 2018-06-01 Wenjie Meng , Jihao Wang , Yubin Hou , Mengqiao Sui , Junting Wang , Gang Wu , Junyun Li , Qingyou Lu

We describe the design, construction, and performance of an ultra-high vacuum (UHV) scanning tunneling microscope (STM) capable of imaging at dilution-refrigerator temperatures and equipped with a vector magnet. The primary objective of our…

Instrumentation and Detectors · Physics 2020-02-07 Dillon Wong , Sangjun Jeon , Kevin P. Nuckolls , Myungchul Oh , Simon C. J. Kingsley , Ali Yazdani

We present the construction and performance of an ultra-low temperature scanning tunneling microscope (STM), working in ultra-high vacuum conditions (UHV) and in high magnetic fields up to 9 T. The cryogenic environment of the STM is…

Strongly Correlated Electrons · Physics 2018-06-12 C. Salazar , D. Baumann , T. Hänke , M. Scheffler , T. Kühne , M. Kaiser , R. Voigtländer , D. Lindackers , B. Büchner , C. Hess

We present a simple on-chip electronic thermometer with the potential to operate down to 1 mK. It is based on transport through a single normal-metal - superconductor tunnel junction with rapidly widening leads. The current through the…

Mesoscale and Nanoscale Physics · Physics 2015-09-29 A. V. Feshchenko , L. Casparis , I. M. Khaymovich , D. Maradan , O. -P. Saira , M. Palma , M. Meschke , J. P. Pekola , D. M. Zumbühl

We report the construction and performance of a low temperature, high field scanning tunneling microscope (STM) operating down to 350mK and in magnetic fields up to 9T, with thin film deposition and in-situ cleaving capabilities. The main…

We discuss basics of scanning tunneling microscopy and spectroscopy (STM/S) of the superconducting state with normal and superconducting tips. We present a new method to measure the local variations in the Andreev reflection amplitude…

In the last decade, detecting spin dynamics at the atomic scale has been enabled by combining techniques like electron spin resonance (ESR) or pump-probe spectroscopy with scanning tunneling microscopy (STM). Here, we demonstrate an…

We present the design and performance of a cryogenic scanning tunneling microscope (STM) which operates inside a water-cooled Bitter magnet, which can attain a magnetic field of up to 38 T. Due to the high vibration environment generated by…

The spectroscopic resolution of tunneling measurements performed with a scanning tunneling microscope is ultimately limited by the temperature at which the experiment is performed. To take advantage of the potential high spectroscopic…

Instrumentation and Detectors · Physics 2007-05-23 H. Le Sueur , P. Joyez