Related papers: Quantum-improved phase estimation with a displacem…
Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these…
We propose a theoretical scheme to improve the precision of phase measurement using intensity detection by implementing delocalized photon subtraction operation (D-PSO) inside the SU(1,1) interferometer, with the coherent state and the…
We propose a novel method for enhancing phase estimation in the displacement-assisted SU(1,1) (DSU(1,1)) interferometer by incorporating the photon recycling technique, evaluated under single-intensity detection (SID) and homodyne detection…
To improve the phase sensitivity, multi-photon subtraction schemes within the SU(1,1) interferometer are proposed. The input states are the coherent state and the vacuum state, and the detection method is homodyne detection. The effects of…
In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity…
We theoretically study the quantum Fisher information (QFI) of the SU(1,1) interferometer with phase shifts in two arms taking account of realistic noise effects. A generalized phase transform including the phase diffusion effect is…
SU(1,1) interferometers, based on the usage of nonlinear elements, are superior to passive interferometers in phase sensitivity. However, the SU(1,1) interferometer cannot make full use of photons carrying phase information as the second…
In an unseeded SU(1,1) interferometer composed of two cascaded degenerate parametric amplifiers, with direct detection at the output, we demonstrate a phase sensitivity overcoming the shot noise limit by 2.3 dB. The interferometer is…
An ${\rm SU(1,1)}$ interferometer uses a sequence of two optical parametric amplifiers for achieving sub-shot-noise sensitivity to a phase shift introduced in between. We present the first realization of a wide-field ${\rm SU(1,1)}$…
Nonlinear interferometers are promising tools for quantum metrology, as they are characterized by an improved phase sensitivity scaling compared to linear interferometers operating with classical light. However, the multimodeness of the…
We propose a theoretical scheme to enhance the phase sensitivity by introducing a Kerr nonlinear phase shift into the traditional SU(1,1) interferometer with a coherent state input and homodyne detection. We investigate the realistic…
We study the phase sensitivity in the conventional $SU(2)$ and nonconventional $SU(1,1)$ interferometers with the coherent and squeezed vacuum input state via the quantum Cramer-Rao bound. We explicitly construct the detection scheme that…
We provide a general theoretical derivation of the phase sensitivity achieved by SU(1,1) interferometers under homodyne detection. The general expressions obtained accommodate arbitrary input states and include internal and external losses.…
The quantum correlation of light and atomic collective excitation can be used to compose an SU(1,1)-type hybrid light-atom interferometer, where one arm in optical SU(1,1) interferometer is replaced by the atomic collective excitation. The…
We analyse a nonlinear interferometer, also known as an SU(1,1) interferometer, in the presence of internal losses and inefficient detectors. To overcome these limitations, we consider the effect of seeding one of the interferometer input…
We consider an SU(1,1) interferometer employing four-wave mixers that is fed with two-mode states which are both coherent and intelligent states of the SU(1,1) Lie group. It is shown that the phase sensitivity of the interferometer can be…
Absolute sensitivity is measured for the phase measurement in an SU(1,1) type interferometer and the results are compared to that of a Mach-Zehnder interferometer operated under the condition of the same intra-interferometer intensity. The…
An SU(1,1) interferometer replaces the beamsplitters in a Mach-Zehnder interferometer with nonlinear interactions and offers the potential of achieving high phase sensitivity in applications with low optical powers. We present a novel…
Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a…
We theoretically investigate the phase sensitivity with parity detection on an SU(1,1) interferometer with a coherent state combined with a squeezed vacuum state. This interferometer is formed with two parametric amplifiers for beam…