Related papers: Signal readout for Transition-Edge Sensor X-ray im…
Kinetic inductance bolometer (KIB) technology is a candidate for passive sub-millimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
Optical sensors offer precision, remote read-out, and immunity to electromagnetic interference but face adoption challenges due to complex and costly readout instrumentation, mostly based on high-resolution. This article challenges the…
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly…
This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National…
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development,…
Large arrays of superconducting transition-edge sensor (TES) microcalorimeters are becoming the key technology for future space-based X-ray observatories and ground-based experiments in the fields of astrophysics, laboratory astrophysics,…
We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on…
Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to…
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at…
Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability…
Microwave SQUID Multiplexing (uMUX) is a widely used technique in the low temperature detectors community as it offers high capacity of reading out large scale Transition-Edge Sensor (TES) arrays. In this paper, we propose a Sliding Flux…
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial…
Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…
We investigate the crosstalk between Transition-Edge Sensor (TES) pixels in a prototype 24-pixel hard X-ray array fabricated at the Advanced Photon Source, Argonne National Laboratory. Analysis shows thermal cross talk, possibly associated…
Transient X-ray absorption techniques can measure ultrafast dynamics of the elemental edges in a material or multiple layer junction, giving them immense potential for deconvoluting concurrent processes. However, the interpretation of the…
The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies…
We are developing code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that…
The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…
Athena is a space-based X-ray observatory intended for exploration of the hot and energetic universe. One of the science instruments on Athena will be the X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer, based…