English
Related papers

Related papers: The XeBRA platform for liquid xenon time projectio…

200 papers

Liquid xenon is a suitable material for a dark matter search. For future large scale experiments, single phase detectors are attractive due to their simple configuration and scalability. However, in order to reduce backgrounds, they need to…

AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…

Instrumentation and Detectors · Physics 2017-11-27 S. Ban , K. D. Nakamura , S. Akiyama , M. Hirose , A. K. Ichikawa , Y. Ishiyama , A. Minamino , K. Miuchi , T. Nakaya , H. Sekiya , S. Tanaka , K. Ueshima , S. Yanagita

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in…

Astrophysics · Physics 2015-06-24 U. G. Oberlack , E. Aprile , A. Curioni , V. Egorov , K. L. Giboni

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…

Cosmology and Nongalactic Astrophysics · Physics 2020-02-19 D. S. Akerib , S. Alsum , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , A. Baxter , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , B. Boxer , P. Brás , S. Burdin , D. Byram , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. R. Fallon , A. Fan , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , J. Genovesi , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , E. Grace , C. Gwilliam , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , R. G. Jacobsen , O. Jahangir , W. Ji , K. Kamdin , K. Kazka , D. Khaitan , R. Knoche , E. V. Korolkova , S. Kravitz , V. A. Kudryavtsev , N. A. Larsen , E. Leason , C. Lee , B. G. Lenardo , K. T. Lesko , C. Levy , J. Liao , J. Lin , A. Lindote , M. I. Lopes , B. López-Paredes , A. Manalaysay , R. L. Mannino , N. Marangou , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , A. Naylor , C. Nehrkorn , H. N. Nelson , F. Neves , A. Nilima , K. O'Sullivan , K. C. Oliver-Mallory , K. J. Palladino , E. K. Pease , L. Reichhart , Q. Riffard , G. R. C. Rischbieter , P. Rossiter , S. Shaw , T. A. Shutt , C. Silva , M. Solmaz , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , R. Taylor , W. C. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , U. Utku , S. Uvarov , A. Vacheret , V. Velan , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , D. Woodward , J. Xu , K. Yazdani , S. K. Young , C. Zhang

We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account…

Instrumentation and Detectors · Physics 2015-10-14 Marc Schumann , Laura Baudis , Lukas Bütikofer , Alexander Kish , Marco Selvi

XENON10 is a new direct dark matter detection experiment using liquid xenon as target for weakly interacting, massive particles (WIMPs). A two-phase (liquid/gas) time projection chamber with 15 kg fiducial mass has been installed in a…

Astrophysics · Physics 2008-11-26 Laura Baudis

We present measurements of light and charge signals in a dual-phase time projection chamber at electric fields varying from 10 V/cm up to 500 V/cm and at zero field using 511 keV gamma rays from a $^{22}$Na source. We determine the drift…

Instrumentation and Detectors · Physics 2018-11-01 E. Hogenbirk , M. P. Decowski , K. McEwan , A. P. Colijn

After operating as a High Energy Physics electron-positron collider, the Cornell Electron-positron Storage Ring (CESR) has been converted to become a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS).…

We present the most recent results from XENON100, the current phase of the XENON dark matter search program. XENON100 is a dual phase time-projection chamber operated at the Laboratori Nazionali del Gran Sasso (LNGS) whose ultra-low…

Cosmology and Nongalactic Astrophysics · Physics 2013-05-14 Paolo Beltrame

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…

LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber (LXe-TPC) with charge and light readout. The first balloon flights in 1997 revealed limitations of the trigger…

Astrophysics · Physics 2009-10-31 E. Aprile , A. Curioni , K. Giboni , U. Oberlack , ; S. Ventura

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any…

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift…

High Energy Physics - Experiment · Physics 2024-03-19 J. Haefner , K. E. Navarro , R. Guenette , B. J. P. Jones , A. Tripathi , C. Adams , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. BenllochRodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , J. V. Carrión , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , T. Contreras , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , E. D. C. Freitas , Z. Freixa , J. Generowicz , A. Goldschmidt , J. J. Gómez-Cadenas , R. González , J. Grocott , K. Hafidi , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , L. Labarga , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , G. Martínez-Lema , M. Martínez-Vara , Z. E. Meziani , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , J. Muñoz Vidal , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , B. Palmeiro , A. Para , I. Parmaksiz , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , J. Rodríguez , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , I. Shomroni , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , J. F. Toledo , J. Torrent , A. Trettin , A. Usón , J. F. C. A. Veloso , J. Waiton , J. T. White

Current detectors for Very-High-Energy $\gamma$-ray astrophysics are either pointing instruments with a small field of view (Cherenkov telescopes), or large field-of-view instruments with relatively large energy thresholds (extensive air…

Instrumentation and Methods for Astrophysics · Physics 2018-03-28 P. Assis , U. Barres de Almeida , A. Blanco , R. Conceição , B. D'Ettore Piazzoli , A. De Angelis , M. Doro , P. Fonte , L. Lopes , G. Matthiae , M. Pimenta , R. Shellard , B. Tomé

We report the calibration of a gaseous Time Projection Chamber based on Micromegas charge readout modules with cosmic ray muons, utilizing their penetrating power and relatively uniform energy deposition per unit length. Muon events were…

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future…

Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection…

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity…

This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…

Medical Physics · Physics 2016-06-01 J. M. Benlloch-Rodriguez