Phasor measurement units (PMUs) can be effectively utilized for the monitoring and control of the power grid. As the cyber-world becomes increasingly embedded into power grids, the risks of this inevitable evolution become serious. In this…

Systems and Control · Computer Science 2016-05-23 Ahmad F. Taha , Junjian Qi , Jianhui Wang , Jitesh H. Panchal

The problem of effective use of Phasor Measurement Units (PMUs) to enhance power systems awareness and security is a topic of key interest. The central question to solve is how to use this new measurements to reconstruct the state of the…

Systems and Control · Electrical Eng. & Systems 2020-04-16 Alexey Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer , M. Nicolai L. Lorenz-Meyer

Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…

Systems and Control · Computer Science 2016-07-12 Jian Du , Shaodan Ma , Yik-Chung Wu , H. Vincent Poor

We propose a novel decentralized mixed algebraic and dynamic state observation method for multi-machine power systems with unknown inputs and equipped with Phasor Measurement Units (PMUs). More specifically, we prove that for the…

Systems and Control · Electrical Eng. & Systems 2020-11-11 M. Nicolai L. Lorenz-Meyer , Alexey A. Bobtsov , Romeo Ortega , Nikolay Nikolaev , Johannes Schiffer

Dynamic state and parameter estimation (DSE) plays a key role for reliably monitoring and operating future, power-electronics-dominated power systems. While DSE is a very active research field, experimental applications of proposed…

Systems and Control · Electrical Eng. & Systems 2022-03-29 Nicolai Lorenz-Meyer , René Suchantke , Johannes Schiffer

Timely recognition of voltage instability is crucial to allow for effective control and protection interventions. Phasor measurements units (PMUs) can be utilized to provide high sampling rate time-synchronized voltage and current phasors…

Systems and Control · Computer Science 2013-08-05 R. Leelaruji , L. Vanfretti , J. O. Gjerde , S. Lovlund

In this paper, a novel method to estimate dynamic load parameters via ambient PMU measurements is proposed. Unlike conventional parameter identification methods, the proposed algorithm does not require the existence of large disturbance to…

Systems and Control · Computer Science 2017-03-10 Xiaozhe Wang

Real-time tracking of inertia is important because it reflects the power system's ability to withstand contingencies and maintain frequency security. This paper proposes a practical approach to estimate inertia using ambient phasor…

Systems and Control · Electrical Eng. & Systems 2025-08-12 Anushka Sharma , Anamitra Pal , Rajasekhar Anguluri , Tamojit Chakraborty

With the continued deployment of synchronized Phasor Measurement Units (PMUs), high sample rate data are rapidly increasing the real time observability of power systems. Prior research has shown that the statistics of these data can provide…

Systems and Control · Computer Science 2018-05-11 Samuel Chevalier , Paul D. H. Hines

Power system dynamics are naturally nonlinear. The nonlinearity stems from power flows, generator dynamics, and electromagnetic transients. Characterizing the nonlinearity of the dynamical power system model is useful for designing superior…

Systems and Control · Computer Science 2019-06-19 Sebastian A. Nugroho , Ahmad F. Taha , Junjian Qi

The problem of imbalance detection in a three-phase power system using a phasor measurement unit (PMU) is considered. A general model for the zero, positive, and negative sequences from a PMU measurement at off-nominal frequencies is…

Applications · Statistics 2016-11-18 Tirza Routtenberg , Yao Xie , Rebecca M. Willett , Lang Tong

The Phasor measurement unit (PMU) measurements are mandatory to monitor the power system's voltage stability margin in an online manner. Monitoring is key to the secure operation of the grid. Traditionally, online monitoring of voltage…

Systems and Control · Electrical Eng. & Systems 2024-12-20 Kishan Prudhvi Guddanti , Amarsagar Reddy Ramapuram Matavalam , Yang Weng

Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…

Systems and Control · Electrical Eng. & Systems 2023-04-18 Saptarshi Ghosh , Murali Sankar Venkatraman , Shehab Ahmed , Charalambos Konstantinou

Integration of intermittent renewable energy sources in modern power systems is increasing very fast. Replacement of synchronous generators with zero-to-low variable renewables substantially decreases the system inertia. In a large system,…

Signal Processing · Electrical Eng. & Systems 2020-06-23 Mingjian Tuo , Xingpeng Li

The statistical characterization of the measurement errors of a phasor measurement unit (PMU) is currently receiving considerable interest in the power systems community. This paper focuses on the characteristics of the errors in magnitude…

Systems and Control · Electrical Eng. & Systems 2021-03-18 Demetra Salls , Jairo Ramírez Torres , Antos Cheeramban Varghese , John Patterson , Anamitra Pal

Installation of phasor measurement units (PMUs) in a number of substations in the power grid can help assess a set of its values and parameters, in particular those related to the dynamics when disturbances occur in the system. Inertia…

Systems and Control · Electrical Eng. & Systems 2021-04-19 Mohammadali Hayerikhiyavi , Aleksandar Dimitrovski

Having actual models for power system components (such as generators and loads or auxiliary equipment) is vital to correctly assess the power system operating state and to establish stability margins. However, power system operators often…

Signal Processing · Electrical Eng. & Systems 2020-01-22 Artem Mikhalev , Alexander Emchinov , Samuel Chevalier , Yury Maximov , Petr Vorobev

Motivated by the need to secure cyber-physical systems against attacks, we consider the problem of estimating the state of a noisy linear dynamical system when a subset of sensors is arbitrarily corrupted by an adversary. We propose a…

Optimization and Control · Mathematics 2015-04-24 Shaunak Mishra , Yasser Shoukry , Nikhil Karamchandani , Suhas Diggavi , Paulo Tabuada

The most commonly used weighted least square state estimator in power industry is nonlinear and formulated by using conventional measurements such as line flow and injection measurements. PMUs (Phasor Measurement Units) are gradually adding…

Systems and Control · Computer Science 2017-03-22 Hossein A. Sangrody , Mohammad Taghi Ameli

In this paper, a phasor measurement unit (PMU)-based wide-area damping control method is proposed to damp the interarea oscillations that threaten the modern power system stability and security. Utilizing the synchronized PMU data, the…

Systems and Control · Electrical Eng. & Systems 2021-08-04 Ilias Zenelis , Xiaozhe Wang