Related papers: In situ X-ray area detector gain correction at an …
Varian Medical Systems has manufactured and recently put into operation a clinically-applicable solution for image-guided radiation therapy. Cone-beam CT imaging, one of the operation modes of the imaging unit of this device, aims at…
Pixel detectors typically display pixel-to-pixel gain variation of a few percent which result in reduced spectroscopic performance. We have developed a calibration method which relies on cross-correlating histograms of many pixel pairs and…
In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…
Grazing incidence X-ray scattering experiments are designed to achieve strong scattering signals from materials, such as molecular monolayers, island films, or thin films that are localized to the surfaces of flat substrates. Optimal…
As photon counting detectors are being explored for medical and industrial imaging applications, there is a critical need to understand spectral characteristics of scattered x-ray photons. Scattered radiation is detrimental to x-ray imaging…
Current methods for detector gain calibration require acquisition of tens of special calibration images. Here we propose a method that obtains the gain from the actual image for which the photon count is desired by quantifying out-of-band…
The development of sensitive large format imaging arrays for the infrared promises to provide revolutionary capabilities for space astronomy. For example, the Infrared Array Camera (IRAC) on SIRTF will use four 256 x 256 arrays to provide…
X-ray free electron laser (XFEL) can provide X-ray light with about four order of magnitude higher flux than synchrotron radiation. Pulse light from XFEL interacts with the target and the resulting photons are collected by detectors. The…
A model-independent method is proposed to characterize and correct charge sharing spectral distortions in energy-resolved X-ray acquisitions with pixellated photon-counting detectors. The technique is based on the determination of a…
A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed x-ray sources has been developed. It allows the direct use of x-ray spectroscopy without artificially decreasing the number of counts in the…
In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are…
When an X-ray area detector based on a single crystalline material, for instance, a state of the art hybrid pixel detector, is illuminated from a point source by monochromatic radiation, a pattern of lines appears which overlays the…
We present a system of X-ray photometry for the Chandra satellite. X-ray photometry can be a powerful tool to obtain flux estimates, hardness ratios, and colors unbiased by assumptions about spectral shape and independent of temporal and…
Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation.…
The short-term X-ray variability of Cyg X-1 can be interpreted as random occurrence of mini-flares known as the shots, whose physical nature is still unclear. We propose a new algorithm for shot identification in the X-ray light curve,…
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the…
Iterative phase retrieval algorithms typically employ projections onto constraint subspaces to recover the unknown phases in the Fourier transform of an image, or, in the case of x-ray crystallography, the electron density of a molecule.…
We present general algorithms to convert scattering data of linear and area detectors recorded in various scattering geometries to reciprocal space coordinates. The presented algorithms work for any goniometer configuration including…
The detection of inelastically scattered soft X-rays with high energy resolution usually requires large grating spectrometers. Recently, photoelectron spectrometry for analysis of X-rays (PAX) has been rediscovered for modern spectroscopy…
Area detectors are used in many scientific and technological applications such as particle and radiation physics. Thanks to the recent technological developments, the radiation sources are becoming increasingly brighter and the detectors…