English
Related papers

Related papers: Low-cost Quadrature Optical Interferometer

200 papers

We describe a laser interferometer experiment for the undergraduate teaching laboratory that achieves picometer sensitivity in a hands-on table-top instrument. In addition to providing an introduction to interferometer physics and optical…

Instrumentation and Detectors · Physics 2015-06-22 Kenneth G. Libbrecht , Eric D. Black

We experimentally demonstrate stable and user-adjustable single-photon interference in a 1 km long fiber- optical Mach-Zehnder interferometer, using an active phase control system with the feedback provided by a classical laser. We are able…

Quantum Physics · Physics 2011-05-06 G. B. Xavier , J. P. von der Weid

An experimental realization of a compact, high-power spectral beamsplitter for nearly equal frequencies and identical polarization based on two-beam interference in a free-space Mach-Zehnder interferometer is presented. We demonstrate the…

Atomic Physics · Physics 2020-04-06 Christian D. Marciniak , Alexander Rischka , Robert N. Wolf , Michael J. Biercuk

We propose a novel design paradigm for arbitrarily capable deep photonic networks of cascaded Mach-Zehnder Interferometers (MZIs) for on-chip universal polarization handling. Using a device architecture made of cascaded Mach-Zehnder…

We present an experiment where we tune the decoherence in a quantum interferometer using one of the simplest object available in the physic of quantum conductors : an ohmic contact. For that purpose, we designed an electronic Mach-Zehnder…

Mesoscale and Nanoscale Physics · Physics 2015-05-13 P. Roulleau , F. Portier , P. Roche , A. Cavanna , G. Faini , U. Gennser , D. Mailly

We use a Mach-Zehnder quantum Hall interferometer of a novel design to investigate the interference effects at fractional filling factors. Our device brings together the advantages of usual Mach-Zehnder and Fabry-Perot quantum Hall…

Mesoscale and Nanoscale Physics · Physics 2015-06-04 E. V. Deviatov , S. V. Egorov , G. Biasiol , L. Sorba

Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to…

Instrumentation and Detectors · Physics 2017-03-01 Oliver Gerberding , Katharina-Sophie Isleif , Moritz Mehmet , Karsten Danzmann , Gerhard Heinzel

A microscope based on the Linnik interferometer was designed, built, and tested. Two methods were used for interference pattern measurement: phase-shifting and polarized single-shot methods. The former uses a low coherence light emitting…

Optics · Physics 2024-06-25 Sergei V. Anishchik , Marcos Dantus

Two optical fiber Mach-Zehnder interferometers were constructed in an environment with a temperature stabilization of better than 1 mK per day. One interferometer with a length of 12 m optical fiber in each arm with the main direction of…

General Physics · Physics 2015-05-13 Victor de Haan

Multiarm interferometers can enhance measurement precision and provide multiparameter capability to the measurement. Their realisation requires multiport beam splitters, which has been a long-standing challenge in free-space and integrated…

Optics · Physics 2022-09-15 Jovana Petrovic , Aleksandra Maluckov , Nikola Stojanovic

Interferometers are essential tools to measure and shape optical fields, and are widely used in optical metrology, sensing, laser physics, and quantum mechanics. They superimpose waves with a mutual phase delay, resulting in a change in…

Phase-shifting interferometry is one of the optical measurement techniques that improves accuracy and resolution by incorporating a controlled phase shift into conventional optical interferometry. In this study, a four-step phase-shifting…

Applied Physics · Physics 2025-03-18 Eita Shoji , Anis Maddi , Guillaume Penelet , Tetsushi Biwa

We study dephasing in an electronic Mach-Zehnder (MZ) interferometer based on quantum Hall (QH) edge states by a micromiter-sized Ohmic contact embedded in one of its arms. We find that at the filling factor $\nu=1$, as well as in the case…

Mesoscale and Nanoscale Physics · Physics 2018-07-18 Edvin G. Idrisov , Ivan P. Levkivskyi , Eugene V. Sukhorukov

Double-slit electron interferometers, fabricated in high mobility two-dimensional electron gas (2DEG), proved to be very powerful tools in studying coherent wave-like phenomena in mesoscopic systems. However, they suffer from small fringe…

Mesoscale and Nanoscale Physics · Physics 2009-11-10 Yang Ji , Yunchul Chung , D. Sprinzak , M. Heiblum , D. Mahalu , Hadas Shtrikman

Programmable linear optical interferometers are a core primitive in optical signal processing, quantum information processing, and photonic computing. Existing photonic-integrated implementations realize arbitrary $M$-mode unitaries using…

We describe construction of an inexpensive Iodine Spectrometer with a home made Iodine vapour cell and a self developed wavemeter based on Pohl Interferometer, around 670 nm wavelength.This can be easily realised in an undergraduate…

Optics · Physics 2020-03-17 Sachin Barthwal , Ashok Vudayagiri

Recent advances in quantum photonics have enabled increasingly robust protocols in optical phase estimation, achieving precisions beyond the standard quantum limit and approaching the Heisenberg limit. While intrinsic losses hinder the…

We present the first experimental study of a new type of power recycling microwave interferometer designed for low noise measurements. This system enhances sensitivity to phase fluctuations in a Device Under Test, independent of input power…

Instrumentation and Detectors · Physics 2016-11-17 Stephen Parker , Eugene Ivanov , Michael Tobar

Spatial coherence of light sources is usually obtained by using the classical Youngs interferometer. Despite the original experiment has been improved in successive works, some drawbacks still remain. In addition, several pairs of points…

Optics · Physics 2024-01-17 FJ Torcal-Milla , J Lobera , EM Roche , AM Lopez , V Palero , N Andres , P Arroyo

A Mach-Zehnder interferometer with absorbing Fabry-P\'{e}rot cavities is used to measure the optical phase differences upon rotation around a vertical axis. The details of the expected experimental results are described based on the idea…

Optics · Physics 2015-04-06 Victor-Otto de Haan