Related papers: Extending MIEZE spectroscopy towards thermal wavel…
Recent progress in neutron spin-echo spectroscopy by means of longitudinal Modulation of IntEnsity with Zero Effort (MIEZE) is reviewed. Key technical characteristics are summarized which highlight that the parameter range accessible in…
We report proof-of-principle measurements at the neutron resonance spin echo spectrometer RESEDA (MLZ) under large magnetic fields by means of Modulation of IntEnsity with Zero Effort (MIEZE). Our study demonstrates the feasibility of…
Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique which allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at…
The RESEDA (Resonant Spin-Echo for Diverse Applications) instrument has been optimized for neutron scattering measurements of quasi-elastic and inelastic processes over a wide parameter range. One spectrometer arm of RESEDA is configured…
The Neutron Spin Echo (NSE) variant MIEZE (Modulation of IntEnsity by Zero Effort), where all beam manipulations are performed before the sample position, offers the possibility to perform low background SANS measurements in strong magnetic…
The MIEZE (Modulation of Intensity with Zero Effort) technique is a variant of neutron resonance spin echo (NRSE), which has proven to be a unique neutron scattering technique for measuring with high energy resolution in magnetic fields.…
Studying the prototypical ferromagnetic superconductor UGe$_2$ we demonstrate the potential of the Modulated IntEnsity by Zero Effort (MIEZE) technique---a novel neutron spectroscopy method with ultra-high energy resolution of at least…
We report the development of a compact turn-key module that boosts the resolution in quasi-elastic neutron scattering by several orders of magnitude down to the low sub-micro-eV range. It is based on a pair of neutron resonance spin…
The instrumental layout and technical realisation of the neutron resonant spin echo (NRSE) spectrometer RESEDA at the Heinz Maier-Leibnitz Zentrum (MLZ) in Garching, Germany, is presented. RESEDA is based on a longitudinal field…
Here, we discuss the comparability of data acquisitioned with the Modulation of IntEnsity with Zero Effort data, a neutron spin-echo (NSE) technique to neutron Time-of-Flight (ToF) spectroscopy data. As a NSE technique MIEZE records the…
A time of flight Modulation of IntEnsity by Zero Effort (MIEZE) spectrometer mode has been developed for the Larmor instrument at the ISIS pulsed neutron source. The instrument utilizes resonant neutron spin flippers which employ…
The cold-neutron three-axis spectrometer MIRA is an instrument optimized for low-energy excitations. Its excellent intrinsic $Q$-resolution makes it ideal for studying incommensurate magnetic systems (elastic and inelastic). MIRA is at the…
The effect of temperature dependent asymmetric line broadening is investigated in Cu(NO$_3$)$_2\cdot$2.5D$_2$O, a model material for a 1-D bond alternating Heisenberg chain, using the high resolution neutron-resonance spin-echo (NRSE)…
We propose the design of a Resonance SPin-echo spECtrometer for exTreme studies, RESPECT, that is ideally suited for the exploration of non-dispersive processes such as diffusion, crystallization, slow dynamics, tunneling processes, crystal…
We study the effect of a finite sample size, beam divergence and detector thickness on the resolution function of a MIEZE spectrometer. We provide a transparent analytical framework which can be used to determine the optimal trade-off…
Recently, a new neutron spectroscopy for the dynamics in complex (bio-) systems has been proposed [A. Benedetto, and G. J. Kearley, Sci. Rep. 6, 34266, (2016)]. This spectroscopy is ideal where only the overall relaxation time in a…
A novel neutron spin resonance technique is presented based on the well-know neutron spin echo method. In a first proof-of-principle measurement using a monochromatic neutron beam, it is demonstrated that relative velocity changes of down…
Thermometry based on magnetic resonance has been extensively studied due to its important application in biomedical imaging. In our previous work, we showed that the spin-spin relaxation time (T2) of nuclear magnetic resonance (NMR) in…
We report on terahertz (THz) electron paramagnetic resonance generalized spectroscopic ellipsometry (THz-EPR-GSE). Measurements of the field and frequency dependencies of the magnetic response due to the spin transitions associated with the…
We describe a resonantly enhanced Mach-Zehnder modulator (MZM) that can be operated over a wide temperature range of 55C without being actively biased, while providing a significant resonant enhancement of 6.8 at the nominal wavelength /…