Related papers: Performance Tests of Feature Extraction Algorithms…
An Early modeling approach of transistors characterized by simplicity and accuracy in representing intrinsic non-linearities is applied to the characterization of propagation delay and level transition switching properties of NPN and PNP…
The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. In addition to its tracking capabilities, the TRT provides particle identification…
A transimpedance amplifier has been designed for scanning tunneling microscopy (STM). The amplifier features low noise (limited by the Johnson noise of the 1 G{\Omega} feedback resistor at low input current and low frequencies), sufficient…
Switched capacitor arrays (SCA) ASICs are becoming more and more popular for the readout of detector signals, since the sampling frequency of typically several gigasamples per second allows excellent pile-up rejection and time measurements.…
In this paper the results of a beam test characterization campaign of 3D trench silicon pixel sensors are presented. A time resolution in the order of 10 ps was measured both for non-irradiated and irradiated sensors up to a fluence of $2.5…
A front end ASIC has been designed to equip the {\mu}TPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC…
We report the first ultrafast pulse radiolysis transient absorption spectroscopy measurements from the Terawatt Ultrafast High Field Facility (TUHFF) at Argonne National Laboratory. TUHFF houses a 20 TW Ti:sapphire laser system that…
A monolithic multi-channel analog transient recorder, implemented using switched capacitor sample-and-hold circuits and a high-speed analogically-adjustable delay-line-based write clock, has been designed, fabricated and tested. The 2.1 by…
Experiments with superconducting circuits require careful calibration of the applied pulses and fields over a large frequency range. This remains an ongoing challenge as commercial semiconductor electronics are not able to probe signals…
In recent years, instrumentation enabling pulsar observations with unprecedentedly high fractional bandwidth has been under development which can be used to substantially improve the precision of pulsar timing experiments. The traditional…
Transient field-resolved spectroscopy enables studies of ultrafast dynamics in molecules, nanostructures, or solids with sub-cycle resolution, but previous work has so far concentrated on extracting the dielectric response at frequencies…
Jitter and shimmer measurements have shown to be carriers of voice quality and prosodic information which enhance the performance of tasks like speaker recognition, diarization or automatic speech recognition (ASR). However, such features…
The extraction of information carried by light plays an increasingly important role in optical communication, imaging, and detection. However, the information can only be successfully extracted when the light pulse is comparably strong,…
The Gaussian phase noise of intensity time series is demonstrated to be drastically reduced when the raw voltage data are digitally filtered through an arbitrarily large number $n$ of orthornormal bandpass profiles (eigen-filters) sharing…
Using pulsed acoustic waves could provide a superior selectivity for microscale acoustic tweezers. However, the theory for the radiation force of pulsed acoustic waves has only been recently derived and no numerical implementations are…
Conventional scanning tunneling microscopy (STM) is limited to a bandwidth of circa 1kHz around DC. Here, we develop, build and test a novel amplifier circuit capable of measuring the tunneling current in the MHz regime while simultaneously…
Attosecond transient absorption spectroscopy (ATAS) has emerged as a powerful technique within the field of attosecond science, combining extremely high temporal and excellent spectral resolution. So far, ATAS has been implemented in…
We demonstrate a high data-rate light-pulse atom interferometer for measuring acceleration. The device is optimized to operate at rates between 50 Hz to 330 Hz with sensitivities of 0.57 {\mu}g/rtHz to 36.7 {\mu}g/rtHz, respectively. Our…
The analysis of speech measures in individuals with amyotrophic lateral sclerosis (ALS) can provide essential information for early diagnosis and tracking disease progression. However, current methods for extracting speech and pause…
This work reports a cost-effective, simple front-end readout and DAQ of a RPC-based muon scattering tomography system under construction. The Time-over-threshold property of NINO ASICs has been exploited to achieve precise tracking by…