The DESY II Test Beam Facility is a key infrastructure for modern high energy physics detector development, providing particles with a small momentum spread in a range from 1 to 6 GeV to user groups e.g. from the LHC experiments and Belle…
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed…
The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank…
Superconducting Quantum Interference Devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pick-up loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with…
Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments…
LiteBIRD is a JAXA-led strategic large-class satellite mission designed to measure the polarization of the cosmic microwave background and Galactic foregrounds from 34 to 448 GHz across the entire sky from L2 in the late 2020s. The…
We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure…
Kinetic Inductance Detectors (KIDs) have become an attractive alternative to traditional bolometers in the sub-mm and mm observing community due to their innate frequency multiplexing capabilities and simple lithographic processes. These…
For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an…
The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and…
In this paper we describe the global on-sky calibration strategy of the LSPE-Strip instrument. Strip is a microwave telescope operating in the Q- and W-bands (central frequencies of 43 and 95 GHz respectively) from the Observatorio del…
One of the primary objectives of modern astronomy is the atmospheric characterization of Earth-like exoplanets at visible and infrared wavelengths. Achieving this goal requires extremely sensitive detectors capable of measuring faint signal…
NIKA2 (New IRAM KID Arrays) is a dual band (150 and 260 GHz) imaging camera based on Kinetic Inductance Detectors (KIDs) and designed to work at the IRAM 30 m telescope (Pico Veleta, Spain). Built on the experience of the NIKA prototype,…
We have fabricated an array of subgap kinetic inductance detectors (SKIDs) made of granular aluminum ($T_c\sim$2~K) sensitive in the 80-90 GHz frequency band and operating at 300~mK. We measure a noise equivalent power of…
The WIYN 3.5m Telescope at Kitt Peak National Observatory hosts a suite of optical and near infrared instruments, including an extreme precision, optical spectrograph, NEID, built for exoplanet radial velocity studies. In order to achieve…
The Liverpool Telescope is one of the world's premier facilities for time domain astronomy. The time domain landscape is set to radically change in the coming decade, with surveys such as LSST providing huge numbers of transient detections…
Astronomical Kinetic Inductance Detectors (KIDs), similar to quantum information devices, experience performance limiting noise from materials. In particular, 1/f (frequency) noise can be a dominant noise mechanism, which arises from…
Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up as a small time dependent jitter of the resonance frequency…
We present a preliminary calibration and flight performance of the Long-Slit Imaging Dual Order Spectrograph (LIDOS), a rocket-borne instrument with a large dynamic range in the 900 - 1700A bandpass. The instrument observes UV-bright…
We present the optical characterization of two-scale hierarchical phased-array antenna kinetic inductance detectors (KIDs) for millimeter/submillimeter wavelengths. Our KIDs have a lumped-element architecture with parallel plate capacitors…