The majority of spatial signal processing techniques focus on increasing the total system capacity and providing high data rates for intended user(s). Unlike the existing studies, this paper introduces a novel interference modulation method…
In this paper, the problem of output feedback sliding mode control of linear sampled-data multi-input multi-output systems is considered. Existing sliding mode control schemes can attenuate the influence of an external disturbance by…
High penetration of renewable energy sources intensifies frequency fluctuations in multi-area power systems, challenging both stability and operational safety. This paper proposes a novel distributed frequency control method that ensures…
It is well-established that a proportional current control gain emulates a resistor in the converter output impedance. Even though this resistance can provide additional damping to grid resonances, its effect for traditional linear current…
Grid forming control applied to power converters that interface storage or renewable generation to the power grid, has been identified as a potential solution to facilitate a substantial share of converter-based renewable generation in the…
Model predictive control (MPC) has proven its applicability in power conversion control with its fast dynamic response to reference changes while ensuring critical system constraints are satisfied. Even then, the computational burden still…
We present a phase control method for a general three-mode system with closed-loop in coupling that drives the system into an entangled steady state and produces directional steering between two completely symmetric modes via quantum…
We report experimental observations of interference between three-photon and one-photon excitations, and phase control of light attenuation/transmission in a four-level system. Either constructive interference or destructive interference…
In Part I of this paper we have introduced the closed-form conditions for guaranteeing regional frequency stability in a power system. Here we propose a methodology to represent these conditions in the form of linear constraints and…
In this work, we investigate grid-forming control for power systems containing three-phase and single-phase converters connected to unbalanced distribution and transmission networks, investigate self-balancing between single-phase…
This paper addresses the closed-loop ramp comparison current regulation in an induction machine fed by a pulse width modulated voltage source inverter. The regulator is implemented in a synchronous frame, serving as a foundation for an…
This paper explores the voltage regulation challenges in boost converter systems, which are critical components in power electronics due to their ability to step up voltage levels efficiently. The proposed control algorithm ensures…
Sampled-data analysis and harmonic balance analysis are applied to analyze switching DC-DC converters under constant on-time control. Design-oriented boundary conditions for the period-doubling bifurcation and the saddle-node bifurcation…
In vibration energy harvesting technologies, feedback control is required to maximize the average power generated from stochastic disturbances. In large-scale applications it is often advantageous to use three-phase conversion technologies…
The method for controlling a DC-DC converter is proposed to ensures the high quality control at large fluctuations in load currents by using differential gain control coefficients and second derivative control. Various implementations of…
With the increasing penetration of converter-interfaced distributed generation systems, it would be advantageous to specify local compliance criteria for these devices to ensure the small-signal stability of the interconnected system.…
An accurate energy efficiency analytical model based on a two-mode circuitry was recently proposed; and the model showed that the use of this circuitry can significantly improve a system's energy efficiency. In this paper, we use this…
Most modern control systems are switched, meaning they have continuous as well as discrete decision variables. Switched systems often have constraints called dwell-time constraints (e.g., cycling constraints in a heat pump) on the switching…
An inevitable consequence of the global power system transition towards nearly 100% renewable-based generation is the loss of conventional bulk generation by synchronous machines, their inertia, and accompanying frequency and voltage…
The traditional secondary frequency control of power systems restores nominal frequency by steering Area Control Errors (ACEs) to zero. Existing methods are a form of integral control with the characteristic that large control gain…