English
Related papers

Related papers: A LN2-based cryogenic system prototype for future …

200 papers

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

Instrumentation and Detectors · Physics 2021-08-11 Xiangyi Cui , Zhou Wang , Yonglin Ju , Xiuli Wang , Huaxuan Liu , Wenbo Ma , Jianglai Liu , Li Zhao , Xiangdong Ji , Shuaijie Li , Rui Yan , Haidong Sha , Peiyao Huang

A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC)…

We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces…

The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…

Muon cooling is the main technological obstacle in the building of a muon collider. A muon cooling scheme based on Frictional Cooling holds promise in overcoming this obstacle. An experiment designed to demonstrate the Frictional Cooling…

Accelerator Physics · Physics 2009-08-21 R. Galea , A. Caldwell , L. Newburgh

The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium…

Temperature control is a complex task due to its often unknown dynamics and disturbances. This paper explores the use of Neural Nonlinear AutoRegressive eXogenous (NNARX) models for nonlinear system identification and model predictive…

Systems and Control · Electrical Eng. & Systems 2024-02-09 Jing Xie , Léo Simpson , Jonas Asprion , Riccardo Scattolini

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller…

Instrumentation and Detectors · Physics 2014-10-27 J. Yoo , H. Cease , W. F. Jaskierny , D. Markley , R. B. Pahlka , D. Balakishiyeva , T. Saab , M. Filipenko

The Proton Improvement Plan II (PIPII) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beams for neutrino production. The Linac requires cooling at 80 K, 5 K, and 2 K temperatures, which will…

Accelerator Physics · Physics 2022-06-23 Ashish Kumar Shukla , Andrew Dalesandro , Ram Dhuley , William Soyars

A water-based cooling system is being investigated to meet the cooling requirement of the Gas Electron Multiplier (GEM) based Muon Chamber (MuCh) detector system of the Compressed Baryonic Matter (CBM) experiment at GSI, Germany. The system…

Current leads are utilized to deliver electrical power from a room temperature junction mounted on the vacuum vessel to a superconducting magnet located within the vacuum space of a cryostat. There are many types of current leads used at…

Accelerator Physics · Physics 2012-09-14 M. J. White , X. L. Wang , H. D. Brueck

Current precision experiments with single (anti)protons to test CPT symmetry progress at a rapid pace, but are complicated by the need to cool particles to sub-thermal energies. We describe a cryogenic Penning-trap setup for $^9$Be$^+$ ions…

A Time to Digital Converter was designed (CMOS 0.35 $\mum) in order to be used in Liquid Xenon PET prototype. The circuit proved to be able to work at -120 degrees C, while showing a resolution of 250 ps. The circuit enables a low readout…

Instrumentation and Detectors · Physics 2007-05-23 O. Bourrion , L. Gallin-Martel

A thermal heat switch has been developed intended for cryogenic space applications operating around 100 K. The switch was designed to separate two pulse tube cold heads that cool a common focal plane array. Two cold heads are used for…

Instrumentation and Detectors · Physics 2013-11-26 Marc Dietrich , Andreas Euler , Günter Thummes

We describe the design and in--flight performance of the cryostat and the self-contained $^{3}$He refrigerator for the OLIMPO balloon--borne experiment, a spectrophotometer to measure the Sunyaev-Zel'dovich effect in clusters of galaxies.…

A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage,…

Instrumentation and Detectors · Physics 2014-11-20 M. Dietrich , G. Thummes

Replacing the bulky cryoliquid-based cooling stages of cryoenabled instruments by chip-scale refrigeration is envisioned to disruptively reduce the system size similar to microprocessors did for computers. Electronic refrigerators based on…

This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9 GHz cryomodules to be used in the…

Accelerator Physics · Physics 2017-12-05 Michael White , Benjamin Hansen , Arkadiy Klebaner

Liquid nitrogen (LN2) is a long-time favorite for physics demonstrations, with a large repertoire of crowd-pleasing experiments that are cornerstones in outreach efforts. While R1 universities usually have a ready LN2 supply for their…

Popular Physics · Physics 2025-10-14 David Marasco , Paolo Marasco