English
Related papers

Related papers: A Comprehensive 3-D Framework for Automatic Quanti…

200 papers

Automatic segmentation of myocardium in Late Gadolinium Enhanced (LGE) Cardiac MR (CMR) images is often difficult due to the intensity heterogeneity resulting from accumulation of contrast agent in infarcted areas. In this paper, we propose…

Image and Video Processing · Electrical Eng. & Systems 2022-05-24 Dong Wei , Ying Sun , Ping Chai , Adrian Low , Sim Heng Ong

Automatic segmentation of the left ventricle (LV) in late gadolinium enhanced (LGE) cardiac MR (CMR) images is difficult due to the intensity heterogeneity arising from accumulation of contrast agent in infarcted myocardium. In this paper,…

Image and Video Processing · Electrical Eng. & Systems 2022-05-24 Dong Wei , Ying Sun , Sim-Heng Ong , Ping Chai , Lynette L. Teo , Adrian F. Low

Accurate computing, analysis and modeling of the ventricles and myocardium from medical images are important, especially in the diagnosis and treatment management for patients suffering from myocardial infarction (MI). Late gadolinium…

Significance: Late gadolinium enhanced magnetic resonance imaging (LGE-MRI) is the gold standard technique for myocardial viability assessment. Although the technique accurately reflects the damaged tissue, there is no clinical standard for…

Computer Vision and Pattern Recognition · Computer Science 2022-04-27 Ezequiel de la Rosa , Désiré Sidibé , Thomas Decourselle , Thibault Leclercq , Alexandre Cochet , Alain Lalande

Late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging is considered the in vivo reference standard for assessing infarct size (IS) and microvascular obstruction (MVO) in ST-elevation myocardial infarction (STEMI)…

Image and Video Processing · Electrical Eng. & Systems 2025-05-15 Matthias Schwab , Mathias Pamminger , Christian Kremser , Daniel Obmann , Markus Haltmeier , Agnes Mayr

Accurate cardiac computing, analysis and modeling from multi-modality images are important for the diagnosis and treatment of cardiac disease. Late gadolinium enhancement magnetic resonance imaging (LGE MRI) is a promising technique to…

Image and Video Processing · Electrical Eng. & Systems 2021-11-10 Lei Li , Fuping Wu , Sihang Wang , Xiahai Zhuang

Accurate segmentation of the cardiac boundaries in late gadolinium enhancement magnetic resonance images (LGE-MRI) is a fundamental step for accurate quantification of scar tissue. However, while there are many solutions for automatic…

Image and Video Processing · Electrical Eng. & Systems 2020-01-14 Víctor M. Campello , Carlos Martín-Isla , Cristian Izquierdo , Steffen E. Petersen , Miguel A. González Ballester , Karim Lekadir

Late gadolinium enhancement (LGE) cardiac MRI (CMR) is the clinical standard for diagnosis of myocardial scar. 3D isotropic LGE CMR provides improved coverage and resolution compared to 2D imaging. However, image acceleration is required…

Image and Video Processing · Electrical Eng. & Systems 2021-06-02 Burhaneddin Yaman , Chetan Shenoy , Zilin Deng , Steen Moeller , Hossam El-Rewaidy , Reza Nezafat , Mehmet Akçakaya

Myocardium segmentation of late gadolinium enhancement (LGE) Cardiac MR images is important for evaluation of infarction regions in clinical practice. The pathological myocardium in LGE images presents distinctive brightness and textures…

Image and Video Processing · Electrical Eng. & Systems 2019-08-15 Xumin Tao , Hongrong Wei , Wufeng Xue , Dong Ni

Segmentation of cardiac fibrosis and scar are essential for clinical diagnosis and can provide invaluable guidance for the treatment of cardiac diseases. Late Gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been…

Image and Video Processing · Electrical Eng. & Systems 2021-07-01 Yinzhe Wu , Zeyu Tang , Binghuan Li , David Firmin , Guang Yang

Accurate representation of myocardial infarct geometry is crucial for patient-specific cardiac modeling in MI patients. While Late gadolinium enhancement (LGE) MRI is the clinical gold standard for infarct detection, it requires contrast…

Image and Video Processing · Electrical Eng. & Systems 2025-07-22 Yilin Lyu , Fan Yang , Xiaoyue Liu , Zichen Jiang , Joshua Dillon , Debbie Zhao , Martyn Nash , Charlene Mauger , Alistair Young , Ching-Hui Sia , Mark YY Chan , Lei Li

In this work, we attempt the segmentation of cardiac structures in late gadolinium-enhanced (LGE) magnetic resonance images (MRI) using only minimal supervision in a two-step approach. In the first step, we register a small set of five LGE…

Image and Video Processing · Electrical Eng. & Systems 2019-10-04 Holger Roth , Wentao Zhu , Dong Yang , Ziyue Xu , Daguang Xu

LGE CMR is an efficient technology for detecting infarcted myocardium. An efficient and objective ventricle segmentation method in LGE can benefit the location of the infarcted myocardium. In this paper, we proposed an automatic framework…

Image and Video Processing · Electrical Eng. & Systems 2019-09-19 Yashu Liu , Wei Wang , Kuanquan Wang , Chengqin Ye , Gongning Luo

Late gadolinium enhancement (LGE) imaging is the clinical standard for myocardial scar assessment, but limited annotated datasets hinder the development of automated segmentation methods. We propose a novel framework that synthesises both…

Computer Vision and Pattern Recognition · Computer Science 2026-02-13 Soufiane Ben Haddou , Laura Alvarez-Florez , Erik J. Bekkers , Fleur V. Y. Tjong , Ahmad S. Amin , Connie R. Bezzina , Ivana Išgum

Segmentation of cardiac images, particularly late gadolinium-enhanced magnetic resonance imaging (LGE-MRI) widely used for visualizing diseased cardiac structures, is a crucial first step for clinical diagnosis and treatment. However,…

Late gadolinium enhanced (LGE) magnetic resonance (MR) imaging is widely established to assess the viability of myocardial tissue of patients after acute myocardial infarction (MI). We propose the Cascading Refinement CNN (CaRe-CNN), which…

Computer Vision and Pattern Recognition · Computer Science 2023-12-20 Franz Thaler , Matthias A. F. Gsell , Gernot Plank , Martin Urschler

Late gadolinium enhancement MRI (LGE MRI) is the gold standard for the detection of myocardial scars for post myocardial infarction (MI). LGE MRI requires the injection of a contrast agent, which carries potential side effects and increases…

Image and Video Processing · Electrical Eng. & Systems 2025-01-10 Guang Yang , Jingkun Chen , Xicheng Sheng , Shan Yang , Xiahai Zhuang , Betty Raman , Lei Li , Vicente Grau

Accurate segmentation of myocardial scar from late gadolinium enhanced (LGE) cardiac MRI is essential for evaluating tissue viability, yet remains challenging due to variable contrast and imaging artifacts. Electrocardiogram (ECG) signals…

Computer Vision and Pattern Recognition · Computer Science 2026-04-02 Farheen Ramzan , Yusuf Kiberu , Nikesh Jathanna , Meryem Jabrane , Vicente Grau , Shahnaz Jamil-Copley , Richard H. Clayton , Chen , Chen

Delayed-enhancement cardiac magnetic resonance (DE-CMR)provides important diagnostic and prognostic information on myocardial viability. The presence and extent of late gadolinium enhancement (LGE)in DE-CMR is negatively associated with the…

Image and Video Processing · Electrical Eng. & Systems 2020-10-19 Ana Lourenço , Eric Kerfoot , Irina Grigorescu , Cian M Scannell , Marta Varela , Teresa M Correia

Cardiac left ventricular (LV) segmentation from short-axis MRI acquired 10 minutes after the injection of a contrast agent (LGE-MRI) is a necessary step in the processing allowing the identification and diagnosis of cardiac diseases such as…

Image and Video Processing · Electrical Eng. & Systems 2020-06-02 Abdul Qayyum , Alain Lalande , Thomas Decourselle , Thibaut Pommier , Alexandre Cochet , Fabrice Meriaudeau
‹ Prev 1 2 3 10 Next ›