English
Related papers

Related papers: SiPM and PMT Driving, Signals Count and Peak Detec…

200 papers

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

Silicon Photomultipliers (SiPMs) are photon-counting detectors with great potential to improve the sensitivity of optical receivers. Recent studies of SiPMs in communication focus on the speed rather than the power consumption of the…

Signal Processing · Electrical Eng. & Systems 2024-04-05 Yangchun Li , Danial Chitnis

Recent years have shown an increased use of silicon photo-multipliers (SiPM) in experiments as they are of reasonable cost, have relatively low power consumption and are easily available in a variety of form factors allowing for a large…

This article presents the development of a cost-effective and efficient electronic module for silicon photomultipliers (SiPM). The electronic module combines essential functionalities, such as a high voltage power supply, a preamplifier,…

Instrumentation and Detectors · Physics 2023-09-07 A. Sadigov , S. Nuruyev , R. Akbarov , D. B. Berikov , A. Madadzada , A. Mammadli

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

Silicon photomultipliers, thanks to their excellent performance, robustness and relatively simple use, are the photon-detectors of choice for many present and future applications. This paper gives an overview of methods to characterise…

Instrumentation and Detectors · Physics 2018-12-19 Robert Klanner

Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read…

Instrumentation and Detectors · Physics 2024-12-04 Peter Fischer , Michael Ritzert , Thomas Kerschenbauer

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

This paper presents design of a Maximum Power Point Tracking (MPPT) circuit and its functionality for tuning the maximum power transfer from an energy harvester (EH) unit. Simple and practical Perturb and Observe algorithm is investigated…

Hardware Architecture · Computer Science 2021-10-25 Adam Hudec , Lukas Nagy , Martin Kovac , Viera Stopjakova

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…

Instrumentation and Detectors · Physics 2020-01-23 Tyana Stiegler , Kareem Kazkaz , Erik Swanberg , Vladimir Mozin

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…

Instrumentation and Methods for Astrophysics · Physics 2025-02-14 Nicolas De Angelis , Franck Cadoux , Coralie Husi , Merlin Kole , Sławomir Mianowski

Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a mo dular high-resolution charged-particle tracking detector has been designed. The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating…

Instrumentation and Detectors · Physics 2007-11-30 H. Gast , R. Greim , T. Kirn , G. Roper Yearwood , S. Schael

An innovative particle detector that offers a compelling combination of cost-effectiveness and high accuracy is introduced. The detector features plastic scintillators paired with a sparse arrangement of SiPMs, strategically positioned…

Instrumentation and Detectors · Physics 2024-10-15 Yoav Simhony , Alex Segal , Yuri Orlov , Ofer Amrani , Erez Etzion

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

Molecular communication requires low-complexity symbol detection algorithms to deal with the many sources of uncertainty that are inherent in these channels. This paper proposes two variants of a high-performance asynchronous peak detection…

Information Theory · Computer Science 2017-02-27 Adam Noel , Andrew W. Eckford

The Multi-voltage Threshold (MVT) method, which samples the signal by certain reference voltages, has been well developed as being adopted in pre-clinical and clinical digital positron emission tomography(PET) system. To improve its energy…

Signal Processing · Electrical Eng. & Systems 2021-03-10 Kezhang Zhu , Junhua Mei , Yuming Su , Pingping Dai , Nicola D'Ascenzo , Hao Wang , Peng Xiao , Lin Wan , Qingguo Xie

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

In recent years, SiPM photoelectric devices have drawn much attention in the domain of time-of-flight-based positron emission tomography (TOF-PET). Using them to construct PET detectors with excellent coincidence time resolution (CTR) is…

Instrumentation and Detectors · Physics 2018-06-08 Liwei Wang , Yonggang Wang , Qiang Cao , Yong Xiao , Chong Liu

A recent report on the over saturation in SiPMs is puzzling. The measurements, using a variety of SiPMs, show an excess in signal far beyond the physical limit of the number of SiPM microcells without indication of an ultimate saturation.…

Instrumentation and Methods for Astrophysics · Physics 2015-07-06 Max Ludwig Ahnen
‹ Prev 1 2 3 10 Next ›