Related papers: Performance of the polarization leakage correction…
The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales (~ 1 degree). Between 2008 October and 2010…
We address in this work the instrumental systematic errors that can potentially affect the forthcoming and future Cosmic Microwave Background experiments aimed at observing its polarized emission. In particular, we focus on the systematics…
Using the first station of the Long Wavelength Array (LWA1), we examine polarized pulsar emission between 25 and 88 MHz. Polarized light from pulsars undergoes Faraday rotation as it passes through the magnetized interstellar medium.…
High precision polarization measurements open new opportunities for the study of the magnetic field structure as traced by polarimetric measurements of the interstellar dust emission. Polarization parameters suffer from bias in the presence…
Sensitive wide-field observations of polarized thermal emission from interstellar dust grains will allow astronomers to address key outstanding questions about the life cycle of matter and energy driving the formation of stars and the…
The Planck satellite in orbit mission ended in October 2013. Between the end of Low Frequency Instrument (LFI) routine mission operations and the satellite decommissioning, a dedicated test was also performed to measure the Planck telescope…
We report on the first results of the POLAMI program, a simultaneous 3.5 and 1.3mm full-Stokes-polarisation monitoring of a sample of 36 of the brightest active galactic nuclei in the northern sky with the IRAM 30m Telescope. Through a…
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that can measure polarization in the energy range 25--240 keV. The instrument adopts an array of well-type "phoswich" detectors in order to suppress backgrounds.…
This paper presents the characterization of the in-flight beams, the beam window functions, and the associated uncertainties for the Planck Low Frequency Instrument (LFI). The structure of the paper is similar to that presented in the 2013…
The Gamma RAy Polarimeter Experiment (GRAPE), a balloon borne Compton polarimeter for 50-500 keV gamma rays, was successfully flown for the second time in 2014. GRAPE consists of 24 collimated polarimeter modules. Each module is made up of…
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40…
We report on full-Stokes L-band observations of 98 MeerKAT calibration sources. Linear polarization is detected in 71 objects above a fractional level of 0.2\%. We identify ten sources with strong fractional linear polarization and low…
In this paper we investigate the impact of using a polarization modulator in the Short Wavelenght Instrument for the Polarization Explorer (SWIPE) of the Large Scale Polarization Explorer (LSPE). The experiment is optimized to measure the…
We present recent improvements in polarization analysis with the INTEGRAL SPI data. The SPI detector plane consists of 19 independent Ge crystals and can operate as a polarimeter. The anisotropy characteristics of Compton diffusions can…
The Sky Polarization Observatory (SPOrt) is presented as a project aimed to measure the diffuse sky polarized emission, from the International Space Station, in the frequency range 20-90 GHz with 7 degrees of HPBW. The SPOrt experimental…
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays…
The turbulent nature of the ionised interstellar medium (IISM) causes dispersion measure (DM) and scattering variations in pulsar timing measurements. To improve precision of gravitational wave measurements, pulsar timing array (PTA)…
The precision physics program of the ILC requires precise knowledge of the state of beam polarisation. In fact the Compton polarimeters intended for the ILC will have to measure the polarisation with error a factor of 2 smaller than the…
A critical challenge in the observation of the redshifted 21-cm line is its separation from bright Galactic and extragalactic foregrounds. In particular, the instrumental leakage of polarized foregrounds, which undergo significant Faraday…
This paper describes the identification, modelling, and removal of previously unexplained systematic effects in the polarization data of the Planck High Frequency Instrument (HFI) on large angular scales, including new mapmaking and…