Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

Recent years have witnessed growing interest in machine learning-based models and techniques for low-dose X-ray CT (LDCT) imaging tasks. The methods can typically be categorized into supervised learning methods and unsupervised or…

Machine Learning · Computer Science 2019-10-29 Zhipeng Li , Siqi Ye , Yong Long , Saiprasad Ravishankar

Low dose CT is of great interest in these days. Dose reduction raises noise level in projections and decrease image quality in reconstructions. Model based image reconstruction can combine statistical noise model together with prior…

Medical Physics · Physics 2019-10-16 Kaichao Liang , Li Zhang , Yirong Yang , HongKai Yang , Yuxiang Xing

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

Image and Video Processing · Electrical Eng. & Systems 2023-02-08 Runyi Li

Recently, deep learning(DL) methods have been proposed for the low-dose computed tomography(LdCT) enhancement, and obtain good trade-off between computational efficiency and image quality. Most of them need large number of pre-collected…

Computer Vision and Pattern Recognition · Computer Science 2018-08-09 Mingrui Geng , Yun Deng , Qian Zhao , Qi Xie , Dong Zeng , Dong Zeng , Wangmeng Zuo , Deyu Meng

Low-dose CT imaging requires reconstruction from noisy indirect measurements which can be defined as an ill-posed linear inverse problem. In addition to conventional FBP method in CT imaging, recent compressed sensing based methods exploit…

Image and Video Processing · Electrical Eng. & Systems 2025-11-14 Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

Ionizing radiation has been the biggest concern in CT imaging. To reduce the dose level without compromising the image quality, low-dose CT reconstruction has been offered with the availability of compressed sensing based reconstruction…

Image and Video Processing · Electrical Eng. & Systems 2025-11-14 Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

In the intention of minimizing excessive X-ray radiation administration to patients, low-dose computed tomography (LDCT) has become a distinct trend in radiology. However, while lowering the radiation dose reduces the risk to the patient,…

Medical Physics · Physics 2022-04-12 Long Zhou , Xiaozhuang Wang , Min Hou , Ping Li , Chunlong Fu , Yanjun Ren , Tingting Shao , Xi Hu , Jihong Sun , Hongwei Ye

Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but…

Image and Video Processing · Electrical Eng. & Systems 2021-02-05 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Deep learning has been successfully applied to low-dose CT (LDCT) image denoising for reducing potential radiation risk. However, the widely reported supervised LDCT denoising networks require a training set of paired images, which is…

Machine Learning · Computer Science 2023-02-09 Yuhui Ruan , Qiao Yuan , Chuang Niu , Chen Li , Yudong Yao , Ge Wang , Yueyang Teng

Deep learning is a very promising technique for low-dose computed tomography (LDCT) image denoising. However, traditional deep learning methods require paired noisy and clean datasets, which are often difficult to obtain. This paper…

Image and Video Processing · Electrical Eng. & Systems 2023-08-15 Yuting Zhu , Qiang He , Yudong Yao , Yueyang Teng

Low-dose CT (LDCT) imaging is desirable in many clinical applications to reduce X-ray radiation dose to patients. Inspired by deep learning (DL), a recent promising direction of model-based iterative reconstruction (MBIR) methods for LDCT…

Image and Video Processing · Electrical Eng. & Systems 2021-02-18 Qiaoqiao Ding , Yuesong Nan , Hao Gao , Hui Ji

Low dose X-ray computed tomography (LDCT) is desirable for reduced patient dose. This work develops image reconstruction methods with deep learning (DL) regularization for LDCT. Our methods are based on unrolling of proximal…

Image and Video Processing · Electrical Eng. & Systems 2020-08-26 Qiaoqiao Ding , Gaoyu Chen , Xiaoqun Zhang , Qiu Huang , Hui Jiand Hao Gao

Since 2016, deep learning (DL) has advanced tomographic imaging with remarkable successes, especially in low-dose computed tomography (LDCT) imaging. Despite being driven by big data, the LDCT denoising and pure end-to-end reconstruction…

Image and Video Processing · Electrical Eng. & Systems 2023-03-28 Wenjun Xia , Hongming Shan , Ge Wang , Yi Zhang

Deep learning (DL) has emerged as a tool for improving accelerated MRI reconstruction. A common strategy among DL methods is the physics-based approach, where a regularized iterative algorithm alternating between data consistency and a…

Image and Video Processing · Electrical Eng. & Systems 2020-07-03 Burhaneddin Yaman , Seyed Amir Hossein Hosseini , Steen Moeller , Jutta Ellermann , Kâmil Uǧurbil , Mehmet Akçakaya

Despite the indispensable role of X-ray computed tomography (CT) in diagnostic medicine field, the associated ionizing radiation is still a major concern considering that it may cause genetic and cancerous diseases. Decreasing the exposure…

Image and Video Processing · Electrical Eng. & Systems 2021-06-09 Ti Bai , Dan Nguyen , Biling Wang , Steve Jiang

Low-dose computed tomography (LDCT) aims to minimize the radiation exposure to patients while maintaining diagnostic image quality. However, traditional CT reconstruction algorithms often struggle with the ill-posed nature of the problem,…

Image and Video Processing · Electrical Eng. & Systems 2024-10-17 Daisy Chen

Commercial iterative reconstruction techniques on modern CT scanners target radiation dose reduction but there are lingering concerns over their impact on image appearance and low contrast detectability. Recently, machine learning,…

Computer Vision and Pattern Recognition · Computer Science 2019-07-16 Hongming Shan , Atul Padole , Fatemeh Homayounieh , Uwe Kruger , Ruhani Doda Khera , Chayanin Nitiwarangkul , Mannudeep K. Kalra , Ge Wang

Computed tomography (CT) has played a vital role in medical diagnosis, assessment, and therapy planning, etc. In clinical practice, concerns about the increase of X-ray radiation exposure attract more and more attention. To lower the X-ray…

Image and Video Processing · Electrical Eng. & Systems 2022-01-19 Zhicheng Zhang , Xiaokun Liang , Wei Zhao , Lei Xing