Related papers: Mobile EEG artifact correction on limited hardware…
Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynamics but require long acquisition times, precluding its widespread use for early diagnosis of cardiovascular disease. To reduce the acquisition times, reconstruction…
Metal Artifacts creates often difficulties for a high quality visual assessment of post-operative imaging in {c}omputed {t}omography (CT). A vast body of methods have been proposed to tackle this issue, but {these} methods were designed for…
In order to reduce the muscle artifacts in multi-channel pervasive Electroencephalogram (EEG) signals, we here propose and compare two hybrid algorithms by combining the concept of wavelet packet transform (WPT), empirical mode…
Rigid-motion artifacts, such as cortical bone streaking and trabecular smearing, hinder in vivo assessment of bone microstructures in high-resolution peripheral quantitative computed tomography (HR-pQCT). Despite various motion grading…
Electron tomography (ET) has become a standard technique for 3D characterization of materials at the nano-scale. Traditional reconstruction algorithms such as weighted back projection suffer from disruptive artifacts with insufficient…
Electrocardiogram (ECG) is a widely used diagnostic tool for detecting heart conditions. Rare cardiac diseases may be underdiagnosed using traditional ECG analysis, considering that no training dataset can exhaust all possible cardiac…
Artifacts pose a significant challenge in medical imaging, impacting diagnostic accuracy and downstream analysis. While image-based approaches for detecting artifacts can be effective, they often rely on preprocessing methods that can lead…
Simultaneously recorded electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can be used to non-invasively measure the spatiotemporal dynamics of the human brain. One challenge is dealing with the artifacts that…
This research addresses a validated TMS EEG cleaning pipeline and a corresponding benchmark dataset. It evaluates two widely used artifact removal pipelines. A reference dataset of carefully preprocessed EEG signals was established to…
Electroencephalography (EEG) signals reflect activities on certain brain areas. Effective classification of time-varying EEG signals is still challenging. First, EEG signal processing and feature engineering are time-consuming and highly…
Electroencephalography (EEG) signal cleaning has long been a critical challenge in the research community. The presence of artifacts can significantly degrade EEG data quality, complicating analysis and potentially leading to erroneous…
This paper describes an exponential transient excision algorithm (ETEA). In biomedical time series analysis, e.g., in vivo neural recording and electrocorticography (ECoG), some measurement artifacts take the form of piecewise exponential…
Recently, many efforts have been made to explore how the brain processes speech using electroencephalographic (EEG) signals, where deep learning-based approaches were shown to be applicable in this field. In order to decode speech signals…
The success of deep learning in computer vision has greatly increased the need for annotated image datasets. We propose an EEG (Electroencephalogram)-based image annotation system. While humans can recognize objects in 20-200 milliseconds,…
Reconstructing 3D visual stimuli from Electroencephalography (EEG) data holds significant potential for applications in Brain-Computer Interfaces (BCIs) and aiding individuals with communication disorders. Traditionally, efforts have…
Continuous electroencephalography (EEG) is routinely used in neurocritical care to monitor seizures and other harmful brain activity, including rhythmic and periodic patterns that are clinically significant. Although deep learning methods…
Magnetic Resonance Imaging (MRI) is a widely used medical imaging modality boasting great soft tissue contrast without ionizing radiation, but unfortunately suffers from long acquisition times. Long scan times can lead to motion artifacts,…
A high fraction of artifact-free signals is highly desirable in functional neuroimaging and brain-computer interfacing (BCI). We present the high-variance electrode artifact removal (HEAR) algorithm to remove transient electrode pop and…
Electroencephalography (EEG) is a neuroimaging technique that records brain neural activity with high temporal resolution. Unlike other methods, EEG does not require prohibitively expensive equipment and can be easily set up using…
Motion artifacts are a primary source of magnetic resonance (MR) image quality deterioration with strong repercussions on diagnostic performance. Currently, MR motion correction is carried out either prospectively, with the help of motion…