Related papers: Scintillation Event Localization in Hemi-Ellipsoid…
An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…
We report on the results of the positional-dependent pulse shape discrimination (PSD) parameter observed within a monolithic CLLB scintillation crystal. CLLB, a relatively novel inorganic scintillation crystal, is capable of PSD between…
A large acceptance scintillator detector with wavelength shifting optical fibre readout has been designed and built to detect the decay particles of $\eta$-nucleus bound system (the so-called $\eta$-mesic nuclei), namely, protons and pions.…
Simulation studies have been carried out to explore the ability to discriminate between single-site and multi-site energy depositions in large scale liquid scintillation detectors. A robust approach has been found that is predicted to lead…
Luminosity profiles of galaxies acting as strong gravitational lenses can be tricky to study. Indeed, strong gravitational lensing images display several lensed components, both point-like and diffuse, around the lensing galaxy. Those…
A future compact and modular X and gamma-ray spectrometer (XGS) has been designed and a series of prototypes have been developed and tested. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25…
We evaluate the performance of an Omnivision OV5647 CMOS image sensor (5 Mp) for detecting radiation from Sr90 and Cs137 sources. Our experimental setup uses a Raspberry Pi 3 mini-computer for data acquisition, with image processing using…
Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…
Crystal calorimeters have a long history of pushing the frontier on high-resolution electromagnetic (EM) calorimetry. We explore in this paper major innovations in collider detector performance that can be achieved with crystal calorimetry…
The performance of a scintillating fiber (2mm diameter) position sensitive detector ($4.8 \times 4.8$ cm$^2$ active area) for the single bremstrahlung luminosity monitor at the VEPP-2M electron-positron collider in Novosibirsk, Russia is…
A test of Geant4 simulation of electron backscattering recently published in this journal prompted further investigation into the causes of the observed behaviour. An interplay between features of geometry and physics algorithms implemented…
Riptide is a detector concept aiming to track fast neutrons. It is based on neutron--proton elastic collisions inside a plastic scintillator, where the neutron momentum can be measured by imaging the scintillation light. More specifically,…
A neutron time projection chamber can locate the approximate direction of a neutron hot spot with high efficiency and a 4{\pi} field of view. The angular resolution can be significantly improved by adding several plastic scintillation…
Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…
The distributions of event-by-event harmonic flow coefficients v_n for n=2-4 are measured in sqrt(s_NN)=2.76 TeV Pb+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using charged particles with transverse…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
In this study, we developed a new proton detector system called CATCH, which was designed for a scattering experiment involving a $\Sigma$ hyperon and a proton (J-PARC E40). CATCH is a cylindrical detector system covering an inner target…
In the present work, we report extensive GEANT4 simulations in order to study the dependence of sensitivity of GAGG:Ce scintillation crystal based detector on thickness of the crystal. All the simulations are made considering a thermalised…
One possibility for detecting low-amplitude pulsational variations is through gravitational microlensing. During a microlensing event, the temporary brightness increase leads to improvement in the signal-to-noise ratio, and thereby better…
Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy…