Related papers: Background Shielding by Dense Samples in Low-Level…
Low background gamma spectrometry employing HPGe detectors is a sensitive technique for measuring low-level radioactivity in environmental applications, material screening, and for rare decay searches. This work presents spectroscopic…
High-purity germanium (HPGe) detectors used for low-background gamma ray spectrometry are usually operated under either a fairly low overburden of the order of one meter of water equivalent (mw.e.) or a high overburden of the order of…
A high efficiency, low background counting setup has been made at TIFR consisting of a special HPGe detector ($\sim$ 70%) surrounded by a low activity copper+lead shield. Detailed measurements are performed with point and extended geometry…
The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for…
High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost…
We present the use of a low background counting facility, equipped with a p-type 80% relative efficiency HPGe detector, protected by active and passive shielding, and large enough to count a 10" photo-multiplier tube (PMT). A GEANT4…
A new approach to study the response of portable gamma detector to terrestrial gamma ray is proposed. This approach is based on two-stage Monte Carlo simulation. First, the probability distributions of the phase space coordinates of the…
The main background above 3\,MeV for in-beam nuclear astrophysics studies with $\gamma$-ray detectors is caused by cosmic-ray induced secondaries. The two commonly used suppression methods, active and passive shielding, against this kind of…
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have…
The Majorana Experiment will use arrays of enriched HPGe detectors to search for the neutrinoless double-beta decay of 76Ge. Such a decay, if found, would show lepton-number violation and confirm the Majorana nature of the neutrino.…
An extremely low-background environment is a crucial requirement for any neutrinoless double beta decay experiment. Neutrons are very difficult to stop, because they can pass through the shields and activate nuclei in the detector, even…
Experiments searching for extremely rare events surround their sensitive detectors with several layers of different shielding materials to protect them from external radiation and to achieve their low-background requirements to be able to…
This paper presents a novel approach to estimate the Standard Model backgrounds based on modifying Monte Carlo predictions within their systematic uncertainties. The improved background model is obtained by altering the original predictions…
$P$-type high-purity germanium (HPGe) detectors are widely used across many scientific domains, and current data analysis methods have served well in many use cases. However, applications like low-background experiments that search for rare…
A Monte Carlo framework, MaGe, has been developed based on the Geant4 simulation toolkit. Its purpose is to simulate physics processes in low-energy and low-background radiation detectors, specifically for the Majorana and Gerda $^{76}$Ge…
Neutrinoless double beta decay ($0\nu\beta\beta$) offers a sensitive probe of neutrino mass and its Majorana nature. Orthogonal-strip high-purity germanium (HPGe) detectors with high spatial resolution provide a promising approach for…
We are currently setting up a facility for low-background gamma-ray spectrometry based on a HPGe detector. It is dedicated to material screening for the XENON and DARWIN dark matter projects as well as to the characterization of meteorites.…
We describe a new high-purity germanium (HPGe) detector setup for low-background {\gamma}-ray spectrometry. The GeMSE facility (Germanium Material and meteorite Screening Experiment) is dedicated to material screening for rare event…
The spatial distribution of the background events may affect the source detection capability of IBIS at high energies (> 200 keV) for both ISGRI and PICsIT layers. The observed background is found to be variable and spatially structured,…
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…