Related papers: Fault Detection and Localization in Active Distrib…
Phasor Measurement Units (PMUs) are essential measuring devices for monitoring, control and protection of power systems. The objective of the optimal PMU placement (OPP) problem is to minimize the number of PMUs and select the bus locations…
Ensuring secure and reliable operations of the power grid is a primary concern of system operators. Phasor measurement units (PMUs) are rapidly being deployed in the grid to provide fast-sampled operational data that should enable quicker…
Phasor measurement units (PMUs) provide accurate and high-fidelity measurements in order to monitor the state of the power grid and support various control and planning tasks. However, PMUs have a high installation cost prohibiting their…
This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that…
In this paper, we present a data-driven Forward Selection with Neighborhood Refinement (FSNR) algorithm to determine the number and placement of Phasor Measurement Units (PMUs) for maximizing deep-learning-based fault diagnosis performance.…
Motivated by increasing penetration of distributed generators (DGs) and fast development of micro-phasor measurement units ({\mu}PMUs), this paper proposes a novel graph-based faulted line identification algorithm using a limited number of…
Today, microgrids in distribution networks are in dire need of improvement to cope with economic challenges, human losses, and equipment placement issues. Today, there is the issue of scattered resources in distribution systems, which has…
A tri-objective optimal Micro Phasor Measurement Units ({\mu}-PMUs) Placement method is presented, with a focus on minimizing the following three parameters: i) the total number of {\mu}-PMU channels, (ii) the maximum state estimation…
Since transmission lines are crucial links in the power system, one line outage event may bring about interruption or even cascading failure of the power system. If a quick and accurate line outage detection and localization can be…
Accurate fault detection and localization in electrical distribution systems is crucial, especially with the increasing integration of distributed energy resources (DERs), which inject greater variability and complexity into grid…
Real-time transmission line outage detection is difficult because of partial phasor measurement unit (PMU) deployment and varying outage signal strength. Existing detection approaches focus on monitoring PMU-measured nodal algebraic states,…
In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An…
Phasor measurement units (PMUs) provide high-fidelity data that improve situation awareness of electric power grid operations. PMU datastreams inform wide-area state estimation, monitor area control error, and facilitate event detection in…
The goal of this paper is to study the impact of the dynamic nature of bus voltage magnitudes and phase angles, which constitute the state of the power system, on the phasor measurement unit (PMU) placement problem. To facilitate this…
Phasor measurement units (PMUs) have the advantage of providing direct measurements of power states. However, as the number of PMUs in a power system is limited, the traditional supervisory control and data acquisition (SCADA) system cannot…
Phasor measurement units (PMUs) are integrated to the transmission networks under the smart grid umbrella. The observability of PMUs is geographically limited due to their high cost in integration. The measurements of PMUs can be…
Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it…
In this paper, we study the placement of Phasor Measurement Units (PMU) for enhancing hybrid state estimation via the traditional Gauss-Newton method, which uses measurements from both PMU devices and Supervisory Control and Data…
Sensors called phasor measurement units (PMUs) are used to monitor the electric power network. The power domination problem seeks to minimize the number of PMUs needed to monitor the network. We extend the power domination problem and…
Large-scale blackouts that have occurred in the past few decades have necessitated the need to do extensive research in the field of grid security assessment. With the aid of synchrophasor technology, which uses phasor measurement unit…