English
Related papers

Related papers: Energy-sensitive scatter estimation and correction…

200 papers

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial…

Image and Video Processing · Electrical Eng. & Systems 2021-09-30 Michael T. McCann , Marc L. Klasky , Jennifer L. Schei , Saiprasad Ravishankar

In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are…

Medical Physics · Physics 2021-01-12 Magnus Aslund , Erik Fredenberg , M. Telman , Mats Danielsson

X-ray photon-counting detectors (PCDs) are drawing an increasing attention in recent years due to their low noise and energy discrimination capabilities. The energy/spectral dimension associated with PCDs potentially brings great benefits…

Medical Physics · Physics 2020-07-08 Mengzhou Li , David S. Rundle , Ge Wang

Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction…

Medical Physics · Physics 2024-12-18 Xin Zhang , Ting Su , Jiongtao Zhu , Hairong Zheng , Dong Liang , Yongshuai Ge

Scattered radiation is a major concern impacting X-ray image-guided procedures in two ways. First, back-scatter significantly contributes to patient (skin) dose during complicated interventions. Second, forward-scattered radiation reduces…

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral…

Medical Physics · Physics 2021-01-21 Erik Fredenberg , Magnus Hemmendorff , Bjorn Cederstrom , Magnus Aslund , Mats Danielsson

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (DE-CBCT) imaging has been increasing. However, the image quality of DE-CBCT remains constrained by the Compton scattered X-ray…

Motion management is a critical component of image guidance radiotherapy for lung cancer. We previously proposed a scheme using kV scattered x-ray photons for marker-less real-time image guidance in lung cancer radiotherapy. This study…

Medical Physics · Physics 2020-09-11 Yanqi Huang , Kai Yang , Youfang Lai , Huan Liu , Chenyang Shen , Yuncheng Zhong , Yiping Shao , Xinhua Li , Bob Liu , Xun Jia

The detection of inelastically scattered soft X-rays with high energy resolution usually requires large grating spectrometers. Recently, photoelectron spectrometry for analysis of X-rays (PAX) has been rediscovered for modern spectroscopy…

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been…

PET requires accurate, precise, and efficient scatter correction techniques. Conventional scatter estimation typically relies on tail-fitted single-scatter simulation (SSS) strategy. However, the accuracy of tail-fitted SSS is limited, for…

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

Scintillators have been widely used in X-ray imaging due to their ability to convert high-energy radiation into visible light, making them essential for applications such as medical imaging and high-energy physics. Recent advances in the…

Instrumentation and Detectors · Physics 2025-04-14 Seokhwan Min , Seou Choi , Simo Pajovic , Sachin Vaidya , Nicholas Rivera , Shanhui Fan , Marin Soljačić , Charles Roques-Carmes

A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…

Instrumentation and Detectors · Physics 2021-01-21 Erik Fredenberg , Mats Lundqvist , Bjorn Cederstrom , Magnus Aslund , Mats Danielsson

X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an…

Medical Physics · Physics 2021-03-05 Tao Zhang , Zhiqiang Chen , Hao Zhou , N. Robert Bennett , Adam S. Wang , Hewei Gao

Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. Contrast-enhanced spectral imaging has been thoroughly investigated,…

Medical Physics · Physics 2021-01-26 Erik Fredenberg , Magnus Aslund , Bjorn Cederstrom , Mats Lundqvist , Mats Danielsson

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

Medical Physics · Physics 2024-01-30 Berk Iskender , Yoram Bresler

In this paper we demonstrate the utility of fusing energy-resolved observations of Compton scattered photons with traditional attenuation data for the joint recovery of mass density and photoelectric absorption in the context of limited…

Computer Vision and Pattern Recognition · Computer Science 2017-07-07 Hamideh Rezaee , Brian Tracey , Eric L. Miller

AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission…

Medical Physics · Physics 2022-06-22 Ida Häggström , Lukas M. Carter , Thomas J. Fuchs , Adam L. Kesner

Organic scintillators are widely used for fast neutron detection and spectroscopy. Several effects complicate the interpretation of results from detectors based upon these materials. First, fast neutrons will often leave a detector before…

Instrumentation and Detectors · Physics 2009-10-29 N. S. Bowden , P. Marleau , J. T. Steele , S. Mrowka , G. Aigeldinger , W. Mengesha
‹ Prev 1 2 3 10 Next ›