Purpose: Patient movement affects image quality in oral and maxillofacial cone-beam CT imaging. While many efforts are made to minimize the possibility of motion during a scan, relatively little attention has been given to motion…

Medical Physics · Physics 2021-07-27 Tao Sun , Reinhilde Jacobs , Ruben Pauwels , Elisabeth Tijskens , Roger Fulton , Johan Nuyts

Diagnostic stroke imaging with C-arm cone-beam computed tomography (CBCT) enables reduction of time-to-therapy for endovascular procedures. However, the prolonged acquisition time compared to helical CT increases the likelihood of rigid…

Image and Video Processing · Electrical Eng. & Systems 2019-12-02 Alexander Preuhs , Michael Manhart , Philipp Roser , Bernhard Stimpel , Christopher Syben , Marios Psychogios , Markus Kowarschik , Andreas Maier

X-ray photon-counting detectors (PCDs) are drawing an increasing attention in recent years due to their low noise and energy discrimination capabilities. The energy/spectral dimension associated with PCDs potentially brings great benefits…

Medical Physics · Physics 2020-07-08 Mengzhou Li , David S. Rundle , Ge Wang

Involuntary motion during weight-bearing cone-beam computed tomography (CT) scans of the knee causes artifacts in the reconstructed volumes making them unusable for clinical diagnosis. Currently, image-based or marker-based methods are…

Computer Vision and Pattern Recognition · Computer Science 2020-10-22 Jennifer Maier , Marlies Nitschke , Jang-Hwan Choi , Garry Gold , Rebecca Fahrig , Bjoern M. Eskofier , Andreas Maier

Photon counting detectors (PCDs) offer promising advancements in computed tomography (CT) imaging by enabling the quantification and 3D imaging of contrast agents and tissue types through multi-energy projections. However, the accuracy of…

Medical Physics · Physics 2023-10-18 Juan C. R. Luna , Mini Das

In conventional 2D DCE-US, motion correction algorithms take advantage of accompanying side-by-side anatomical Bmode images that contain time-stable features. However, current commercial models of 3D DCE-US do not provide side-by-side Bmode…

Image and Video Processing · Electrical Eng. & Systems 2020-10-06 Jia-Shu Chen , Maged Goubran Ph. D. , Gaeun Kim , Jurgen K. Willmann M. D. , Michael Zeineh M. D. , Ph. D. , Dimitre Hristov Ph. D. , Ahmed El Kaffas Ph. D

X-ray computed tomography (CT) based on photon counting detectors (PCD) extends standard CT by counting detected photons in multiple energy bins. PCD data can be used to increase the contrast-to-noise ratio (CNR), increase spatial…

Image and Video Processing · Electrical Eng. & Systems 2024-02-05 Natalie M. Jadue , Madhuri Nagare , Jonathan S. Maltz , Gregery T. Buzzard , Charles A. Bouman

This study presents a practical and dose-efficient strategy for resolution enhancement in planar radiography, based on mechanically supersampled acquisition with high-Z photon-counting detectors (PCDs). Unlike prior event-based or cluster…

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

Computer Vision and Pattern Recognition · Computer Science 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Recent development of photon-counting CT (PCCT) brings great opportunities for plaque characterization with much-improved spatial resolution and spectral imaging capability. While existing coronary plaque PCCT imaging results are based on…

Medical Physics · Physics 2023-12-05 Mengzhou Li , Mingye Wu , Jed Pack , Pengwei Wu , Bruno De Man , Adam Wang , Koen Nieman , Ge Wang

Deep learning based computed tomography (CT) reconstruction has demonstrated outstanding performance on simulated 2D low-dose CT data. This applies in particular to domain adapted neural networks, which incorporate a handcrafted physics…

Image and Video Processing · Electrical Eng. & Systems 2023-11-30 Jevgenija Rudzusika , Buda Bajić , Thomas Koehler , Ozan Öktem

For single source helical Computed Tomography (CT), both Filtered-Back Projection (FBP) and statistical iterative reconstruction have been investigated. However for dual source CT with flying focal spot (DS-FFS CT), statistical iterative…

Image and Video Processing · Electrical Eng. & Systems 2022-02-14 Xiao Wang , Robert D. MacDougall , Peng Chen , Charles A. Bouman , Simon K. Warfield

Compared with the start-of-art energy integration detectors (EIDs), photon-counting detectors (PCDs) with energy discrimination capabilities have demonstrated great potentials in various applications of medical x-ray radiography and…

Medical Physics · Physics 2018-05-01 Ruibin Feng , David Rundle , Ge Wang

Industrial cone-beam X-ray computed tomography (CT) scans of additively manufactured components produce a 3D reconstruction from projection measurements acquired at multiple predetermined rotation angles of the component about a single…

Image and Video Processing · Electrical Eng. & Systems 2024-07-19 Jingsong Lin , Singanallur Venkatakrishnan , Gregery Buzzard , Amir Koushyar Ziabari , Charles Bouman

Photon-counting spectral computed tomography is now clinically available. These new detectors come with the promise of higher contrast-to-noise ratio and spatial resolution and improved low-dose imaging. However, one important design…

Medical Physics · Physics 2023-02-03 Dennis Hein , Konstantinos Liappis , Fredrik Grönberg , Alma Eguizabal , Mats Persson

Computed tomography (CT) relies on precise patient immobilization during image acquisition. Nevertheless, motion artifacts in the reconstructed images can persist. Motion compensation methods aim to correct such artifacts post-acquisition,…

Image and Video Processing · Electrical Eng. & Systems 2024-05-30 Mareike Thies , Fabian Wagner , Noah Maul , Siyuan Mei , Mingxuan Gu , Laura Pfaff , Nastassia Vysotskaya , Haijun Yu , Andreas Maier

Thanks to its capability of acquiring full-view frames at multiple kilohertz, ultrafast ultrasound imaging unlocked the analysis of rapidly changing physical phenomena in the human body, with pioneering applications such as ultrasensitive…

Image and Video Processing · Electrical Eng. & Systems 2020-12-22 Dimitris Perdios , Manuel Vonlanthen , Florian Martinez , Marcel Arditi , Jean-Philippe Thiran

Motion during image acquisition can cause image degradation in all medical imaging modalities. This is particularly relevant in 2-D ultrasound imaging, since out-of-plane motion can only be compensated for movements smaller than elevational…

Medical Physics · Physics 2019-02-07 S. Harput , K. Christensen-Jeffries , J. Brown , J. Zhu , G. Zhang , R. J. Eckersley , C. Dunsby , M-X. Tang

Short-scan FDK reconstruction is widely used in preclinical cone-beam micro-CT because it reduces scan time and radiation dose, and because the large volume sizes typical of micro-CT make iterative methods impractical for routine use. Short…

Medical Physics · Physics 2026-04-28 Falk L Wiegmann , Nancy L Ford

A hybrid imaging system consisting of a standard CT scanner and a low-profile photon-counting detector insert in contact with the patient's body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of…

Medical Physics · Physics 2022-09-05 Dakota H. King , Eric E. Bennett , Dumitru Mazilu , Muyang Wang , Marcus Y. Chen , Han Wen