English
Related papers

Related papers: Transition edge sensor based detector: from X-ray …

200 papers

Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…

Instrumentation and Detectors · Physics 2026-04-29 Jodok Zeuner , Constantin Schuster , Sebastian Kempf

Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…

Instrumentation and Detectors · Physics 2023-10-26 Constantin Schuster , Sebastian Kempf

We report the implementation of energy dispersive X-ray spectroscopy for layered semiconductors in the form of atomically thin transition metal dichalcogenides. The technique is based on a scanning electron microscope equipped with a…

Mesoscale and Nanoscale Physics · Physics 2022-11-17 Anna Rupp , Jonas Göser , Zhijie Li , Philipp Altpeter , Ismail Bilgin , Alexander Högele

The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical…

We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…

The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the…

Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…

Instrumentation and Methods for Astrophysics · Physics 2024-08-16 K. R. Ferguson , A. N. Bender , N. Whitehorn , T. W. Cecil

We report the first calorimetric detection of individual He2* excimers within a bath of superfluid 4He. The detector used in this work is a single superconducting titanium transition edge sensor (TES) with an energy resolution of ~1 eV,…

Other Condensed Matter · Physics 2016-11-03 F. W. Carter , S. A. Hertel , M. J. Rooks , P. V. E. McClintock , D. N. McKinsey , D. E. Prober

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high…

Astrophysics · Physics 2009-11-06 Tadayui Takahashi , Shin Watanabe

We show the proof-of-principle detection of light at 1550 nm coupled evanescently from a titanium in-diffused lithium niobate waveguide to a superconducting transition edge sensor. The coupling efficiency strongly depends on the…

The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The…

Instrumentation and Detectors · Physics 2019-07-26 Tengfei Yan , Chunlei Yang , Xiaodong Cui

In electrically substituted radiometers, the ultra low noise control of the temperature is required. In this framework, we present results dedicated to the temperature regulation of copper plates, 3 cm diameter and 1 mm thick, using…

Instrumentation and Detectors · Physics 2016-11-18 Bruno Guillet , Didier Robbes , Laurence Mechin

In this paper we explore the application of cryogenic imaging spectrophotometers. Prototypes of this new class of detector, such as superconducting tunnel junctions (STJs) and transition edge sensors (TESs), currently deliver low resolution…

Astrophysics · Physics 2009-10-31 Ben A. Mazin , Robert J. Brunner

A transient and high sensitivity sensor based on high-Q microcavity is proposed and studied theoretically. There are two ways to realize the transient sensor: monitor the spectrum by fast scanning of probe laser frequency or monitor the…

Sensitive photon detection in the gigahertz band constitutes the cornerstone to study different phenomena in astronomy, such as radio burst sources, galaxy formation, cosmic microwave background, axions, comets, gigahertz-peaked spectrum…

Mesoscale and Nanoscale Physics · Physics 2020-09-23 Federico Paolucci , Nadia Ligato , Vittorio Buccheri , Gaia Germanese , Pauli Virtanen , Francesco Giazotto

Transition Radiation (TR) plays an important role in particle identification in high-energy physics and its characteristics provide a feasible method of energy calibration in the energy range up to 10 TeV, which is of interest for dark…

Instrumentation and Methods for Astrophysics · Physics 2020-04-06 Bo Huang , Hongbang Liu , Xuefeng Huang , Ming Xu , Yongwei Dong , Xiaotong Wei , Xiwen Liu , Huanbo Feng , Qinhe Yang , Jianyu Gu , Shuai Chen , Xiaochuan Xie , Jin Zhang , Yongbo Huang , Enwei Liang

The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…

We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray micro-calorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a…

The responsivity and noise of a voltage-biased superconducting transition-edge sensor depends strongly on the details of its thermal model, and the simplest theory for TES response assumes a single heat capacity connected to the heat bath.…

Superconductivity · Physics 2012-10-26 Ilari J. Maasilta

We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was measured at the beam-line in the PTB radiometry laboratory…