Related papers: Transition edge sensor based detector: from X-ray …
The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce…
Transition Edge Sensors (TES) are superconducting microcalorimeters that can be used for single-photon detection with extremely low backgrounds. When they are within their superconducting transition region, small temperature fluctuations -…
Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the…
Significant advancements have been made in understanding the physics of transition-edge sensors (TESs) over the past decade. However, key questions remain, particularly a detailed understanding of the current-dependent resistance of these…
A 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition if a hypothetical elementary particle, axion, exists to solve the strong CP problem. Transition edge sensor (TES) X-ray microcalorimeters…
The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed,…
We describe a process route to fabricate arrays of Ultra-low-Noise MoAu Transition Edge Sensors (TESs). The low thermal conductance required for space applications is achieved using 200 nm-thick Silicon Nitride (SiNx ) patterned to form…
Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to…
Transition-edge sensors (TES) are photon-number resolving calorimetric spectrometers with near unit efficiency. Their recovery time, which is on the order of microseconds, limits the number resolving ability and timing accuracy in high…
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…
We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more…
Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus…
High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute.…
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…
Far-infrared Transition Edge Sensors (TESs) are being developed for the SAFARI grating spectrometer on the cooled-aperture space telescope SPICA. In support of this work, we have devised a cryogenic (90 mK) test facility for carrying out…
Transition edge sensor microcalorimeters can measure x-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future x-ray observatories, each…
AlMn alloy flms are widely fabricated into superconducting transition edge sensors (TESs) for the detection of cosmic microwave background radiation. However, the application in X-ray or gamma-ray detection based on AlMn TES is rarely…
If a hypothetical elementary particle called an axion exists, to solve the strong CP problem, a 57Fe nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition. If such axions are once more transformed…
Transition edge sensors (TES) have the highest reported efficiencies (>98%) for detection of single photons in the visible and near infrared. Experiments in quantum information and foundations of physics that rely critically on this…
Transient X-ray absorption techniques can measure ultrafast dynamics of the elemental edges in a material or multiple layer junction, giving them immense potential for deconvoluting concurrent processes. However, the interpretation of the…