Plastic scintillators are a versatile and inexpensive option for particle detection, which is why the largest particle physics experiments, CMS and ATLAS, use them extensively in their calorimeters. One of their challenging aspects,…
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given…
The FLASH effect holds significant potential in improving radiotherapy treatment outcomes. Very high energy electrons (VHEEs) can effectively target tumors deep in the body and can be accelerated to achieve ultra-high dose rates (UHDR),…
Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application.…
Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator…
Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in…
POLAR-2, a plastic scintillator based Compton polarimeter, is currently under development and planned for a launch to the China Space Station in 2025. It is intended to shed a new light on our understanding of Gamma-Ray Bursts by performing…
The total ionizing radiation (TID) response of commercial NPN silicon germanium hetero-junction bipolar transistors (SiGe HBTs) produced domestic were investigated under the dose rate of 800mGy(Si)/s and 1.3mGy(Si)/s with Co-60 gamma…
We study the optical properties of glass exposed to ionizing radiation, as it occurs in the space environment. 24 glass types have been considered, both space qualified and not space qualified. 72 samples (3 for each glass type) have been…
We report on a novel method for tuning and enhancing fluorescence from irradiated polystyrene through electron-beam exposure in gaseous environments. We describe the effect of electron dose and ambient gas on the photoluminescence spectra…
The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the…
We present a comprehensive account of the proton radiation hardness of Eljen Technology's EJ-500 optical cement used in the construction of experiment detectors. The cement was embedded into five plastic scintillator tiles which were each…
Ferritic/martensitic steels will be used as structural components in next generation nuclear reactors. Their successful operation relies on an understanding of irradiation-induced defect behaviour in the material. In this study, Fe and FeCr…
This work reports the fabrication and optical characterization of ultraviolet-emitting plastic scintillators based on polystyrene [-(CH2-CH(C6H5))n-] and polyvinyltoluene [-(CH2-CH(C6H4CH3))n-] doped with different concentrations of…
Eight PbWO4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 E13 p/cm2. The damage recovery in these crystals, stored in the dark at room…
Radiation hardness studies of KURARAY SCSF-78M scintillating fibers and clear fibers from KURARAY and pol.hi.tech. performed under different dose rate conditions in proton and electron beams are summarized. For high dose rates in-situ…
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm…
Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…
FLASH-RT has proven beneficial in preclinical studies. However, the lack of accurate real time 2D dosimetry is a limiting factor. In this work, an innovative solution for 2D real time dosimetry in UHDR electron beams is presented. The…
Ultra-high dose rate electron sources require dose rate independent dosimeters and a calibrated dose control system for accurate delivery. In this study, we developed a single-pulse dose monitoring and a real-time dose-based control system…