Related papers: Vibration Analysis of KAGRA Cryostat at Cryogenic …
In low temperature transport measurements, there is frequently a need to protect a device at cryogenic temperatures from thermal noise originating in warmer parts of the experiment. There are also a wide range of experiments, such as high…
The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest…
Preparing and manipulating quantum states of mechanical resonators is a highly interdisciplinary undertaking that now receives enormous interest for its far-reaching potential in fundamental and applied science. Up to now, only nanoscale…
A reciprocating quantum refrigerator is analyzed with the intention to study the limitations imposed by external noise. In particular we focus on the behavior of the refrigerator when it approaches the absolute zero. The cooling cycle is…
We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…
Conventional CMOS technology operated at cryogenic conditions has recently attracted interest for its uses in low-noise electronics. We present one of the first characterizations of 180 nm CMOS technology at a temperature of 100 mK,…
Dry Dilution Refrigerators (DDR) based on pulse tube cryo-coolers have started to replace Wet Dilution Refrigerators (WDR) due to the ease and low cost of operation. However these advantages come at the cost of increased vibrations, induced…
We report experimental demonstration of the feasibility of reaching temperatures below 1 mK using cryogen-free technology. Our prototype system comprises an adiabatic nuclear demagnetisation stage, based on hyperfine-enhanced nuclear…
We experimentally demonstrate the high-sensitivity optical monitoring of a micro-mechanical resonator and its cooling by active control. Coating a low-loss mirror upon the resonator, we have built an optomechanical sensor based on a very…
The sensitivity of the gravitational-wave detector KAGRA, presently under construction, will be limited by quantum noise in a large fraction of its spectrum. The most promising technique to increase the detector sensitivity is the injection…
We examine changes in the depinning threshold and conduction noise fluctuations for driven Wigner crystals in the presence of quenched disorder. At low temperatures there is a well defined depinning threshold and a strong peak in the noise…
We explore the viability of using optical refrigeration as a low-vibration cooling method for a phase-sensitive optomechanical amplifier proposed to improve the sensitivity of future gravitational wave detectors. We find that with moderate…
We describe the cryogenic system for SPIDER, a balloon-borne microwave polarimeter that will map 8% of the sky with degree-scale angular resolution. The system consists of a 1284 L liquid helium cryostat and a 16 L capillary-filled…
A cryogenic quantum dot thermometer is calibrated and operated using only a single non-galvanic gate connection. The thermometer is probed with radio-frequency reflectometry and calibrated by fitting a physical model to the phase of the…
Mm and sub-mm waves polarimetry is the new frontier of research in Cosmic Microwave Background and Interstellar Dust studies. Polarimeters working in the IR to MM range need to be operated at cryogenic temperatures, to limit the systematic…
Electric field noise from fluctuating patch potentials is a significant problem for a broad range of precision experiments, including trapped ion quantum computation and single spin detection. Recent results demonstrated strong suppression…
During the On-Station Thermal Test campaign of the LISA Pathfinder the data and diagnostics subsystem was tested in nearly space conditions for the first time after integration in the satellite. The results showed the compliance of the…
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint…
We have investigated crystalline AlGaAs/GaAs optical coatings with three ultra-stable cavities operating at 4 K, 16 K, 124 K and 297 K. The response of the resonance frequencies of cavities to variations in optical power indicates effects…
IR (Infra-Red) detectors are widely used in Space-borne remote sensing satellites. In order to achieve a high signal to noise ratio, the IR detectors need to be operated at cryogenic temperatures. Traditionally, the cryogenic cooling of…