English
Related papers

Related papers: Mass-difference measurements on heavy nuclides wit…

200 papers

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut f\"ur Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy…

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these…

We use an electric-dipole laser-driven transition to precisely measure the cyclotron-frequency ratios of the pairs $^{42}$Ca$^+$-$^{40}$Ca$^+$, $^{44}$Ca$^+$-$^{40}$Ca$^+$ and $^{48}$Ca$^+$-$^{40}$Ca$^+$ in a 7-tesla Penning trap. A single…

The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. Currently, the most precise…

State-of-the-art optical clocks achieve fractional precisions of $10^{-18}$ and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions…

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing…

Accepted values of the masses of several subatomic particles have been under debate since recent measurements in Penning traps produced more precise yet incompatible results, implying possible inconsistencies in closely related physical…

Our knowledge of binding energies of neutron-rich nuclei has experienced a major revision during the last five years due to the introduction of Penning-trap based mass measurements. New mass values for nearly 300 nuclides produced in…

Nuclear Experiment · Physics 2015-06-11 Juha Äystö

The cyclotron frequency ratio of $^{187}\mathrm{Os}^{29+}$ to $^{187}\mathrm{Re}^{29+}$ ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of $R=1.000\:000\:013\:882(5)$ is to date the most precise such…

We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron…

For the first time a direct determination of the atomic mass difference of 187Re and 187Os has been performed with the Penning-trap mass spectrometer SHIPTRAP applying the novel phase-imaging ion-cyclotron-resonance technique. The obtained…

Revolution frequency measurements of individual ions in storage rings require sophisticated timing detectors. One of common approaches for such detectors is the detection of secondary electrons released from a thin foil due to penetration…

We present precision Penning-trap mass measurements of neutron-rich calcium and potassium isotopes in the vicinity of neutron number N=32. Using the TITAN system the mass of $^{51}$K was measured for the first time, and the precision of the…

Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be…

High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the…

A high-precision measurement of the $^{131}$Cs$ \rightarrow ^{131}$Xe ground-to-ground-state electron-capture $Q_{\textrm{EC}}$-value was performed using the ISOLTRAP mass spectrometer at ISOLDE/CERN. The novel PI-ICR technique allowed to…

Although it is known that the $N=28$ spherical shell closure erodes, the strength of the closure with decreasing proton number $Z<20$ is an open question in nuclear structure. In this region of interest, direct high-precision mass…

In Penning traps electromagnetic forces are used to confine charged particles under well-controlled conditions for virtually unlimited time. Sensitive detection methods have been developed to allow observation of single stored ions. Various…

Atomic Physics · Physics 2022-03-16 Klaus Blaum , Sergey Eliseev , Sven Sturm

We report on the first direct mass measurements of the $^{118,119}$Cd and $^{117-119}$In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The masses of…

The masses of the lightest atomic nuclei and the electron mass are interlinked and are crucial in a wide range of research fields, with their values affecting observables in atomic, molecular and neutrino physics as well as metrology. The…

‹ Prev 1 2 3 10 Next ›